Cargando…

A Magnetic Levitation System for Range/Sensitivity-Tunable Measurement of Density

Magnetic levitation (MagLev) is a promising density-based analytical technique with numerous applications. Several MagLev structures with different levels of sensitivity and range have been studied. However, these MagLev structures can seldom satisfy the different performance requirements simultaneo...

Descripción completa

Detalles Bibliográficos
Autores principales: Yu, Junhui, Li, Donghai, Zhu, Chengxian, Ouyang, Qiran, Miao, Chunyang, Yu, Haidong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10143956/
https://www.ncbi.nlm.nih.gov/pubmed/37112295
http://dx.doi.org/10.3390/s23083955
_version_ 1785033985147011072
author Yu, Junhui
Li, Donghai
Zhu, Chengxian
Ouyang, Qiran
Miao, Chunyang
Yu, Haidong
author_facet Yu, Junhui
Li, Donghai
Zhu, Chengxian
Ouyang, Qiran
Miao, Chunyang
Yu, Haidong
author_sort Yu, Junhui
collection PubMed
description Magnetic levitation (MagLev) is a promising density-based analytical technique with numerous applications. Several MagLev structures with different levels of sensitivity and range have been studied. However, these MagLev structures can seldom satisfy the different performance requirements simultaneously, such as high sensitivity, wide measurement range, and easy operation, which have prevented them from being widely used. In this work, a tunable MagLev system was developed. It is confirmed by numerical simulation and experiments that this system possesses a high resolution down to 10(−7) g/cm(3) or even higher compared to the existing systems. Meanwhile, the resolution and range of this tunable system can be adjusted to meet different requirements of measurement. More importantly, this system can be operated simply and conveniently. This bundle of characteristics demonstrates that the novel tunable MagLev system could be handily applied in various density-based analyses on demand, which would greatly expand the ability of MagLev technology.
format Online
Article
Text
id pubmed-10143956
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-101439562023-04-29 A Magnetic Levitation System for Range/Sensitivity-Tunable Measurement of Density Yu, Junhui Li, Donghai Zhu, Chengxian Ouyang, Qiran Miao, Chunyang Yu, Haidong Sensors (Basel) Article Magnetic levitation (MagLev) is a promising density-based analytical technique with numerous applications. Several MagLev structures with different levels of sensitivity and range have been studied. However, these MagLev structures can seldom satisfy the different performance requirements simultaneously, such as high sensitivity, wide measurement range, and easy operation, which have prevented them from being widely used. In this work, a tunable MagLev system was developed. It is confirmed by numerical simulation and experiments that this system possesses a high resolution down to 10(−7) g/cm(3) or even higher compared to the existing systems. Meanwhile, the resolution and range of this tunable system can be adjusted to meet different requirements of measurement. More importantly, this system can be operated simply and conveniently. This bundle of characteristics demonstrates that the novel tunable MagLev system could be handily applied in various density-based analyses on demand, which would greatly expand the ability of MagLev technology. MDPI 2023-04-13 /pmc/articles/PMC10143956/ /pubmed/37112295 http://dx.doi.org/10.3390/s23083955 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Yu, Junhui
Li, Donghai
Zhu, Chengxian
Ouyang, Qiran
Miao, Chunyang
Yu, Haidong
A Magnetic Levitation System for Range/Sensitivity-Tunable Measurement of Density
title A Magnetic Levitation System for Range/Sensitivity-Tunable Measurement of Density
title_full A Magnetic Levitation System for Range/Sensitivity-Tunable Measurement of Density
title_fullStr A Magnetic Levitation System for Range/Sensitivity-Tunable Measurement of Density
title_full_unstemmed A Magnetic Levitation System for Range/Sensitivity-Tunable Measurement of Density
title_short A Magnetic Levitation System for Range/Sensitivity-Tunable Measurement of Density
title_sort magnetic levitation system for range/sensitivity-tunable measurement of density
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10143956/
https://www.ncbi.nlm.nih.gov/pubmed/37112295
http://dx.doi.org/10.3390/s23083955
work_keys_str_mv AT yujunhui amagneticlevitationsystemforrangesensitivitytunablemeasurementofdensity
AT lidonghai amagneticlevitationsystemforrangesensitivitytunablemeasurementofdensity
AT zhuchengxian amagneticlevitationsystemforrangesensitivitytunablemeasurementofdensity
AT ouyangqiran amagneticlevitationsystemforrangesensitivitytunablemeasurementofdensity
AT miaochunyang amagneticlevitationsystemforrangesensitivitytunablemeasurementofdensity
AT yuhaidong amagneticlevitationsystemforrangesensitivitytunablemeasurementofdensity
AT yujunhui magneticlevitationsystemforrangesensitivitytunablemeasurementofdensity
AT lidonghai magneticlevitationsystemforrangesensitivitytunablemeasurementofdensity
AT zhuchengxian magneticlevitationsystemforrangesensitivitytunablemeasurementofdensity
AT ouyangqiran magneticlevitationsystemforrangesensitivitytunablemeasurementofdensity
AT miaochunyang magneticlevitationsystemforrangesensitivitytunablemeasurementofdensity
AT yuhaidong magneticlevitationsystemforrangesensitivitytunablemeasurementofdensity