Cargando…
Acute and Subacute Toxicity Evaluation of Erythrocyte Membrane-Coated Boron Nitride Nanoparticles
Boron nitride nanoparticles have been reported for boron drug delivery. However, its toxicity has not been systematically elucidated. It is necessary to clarify their potential toxicity profile after administration for clinical application. Here, we prepared erythrocyte membrane-coated boron nitride...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10144386/ https://www.ncbi.nlm.nih.gov/pubmed/37103271 http://dx.doi.org/10.3390/jfb14040181 |
_version_ | 1785034087700889600 |
---|---|
author | He, Jinfeng Zhang, Xuanping Liu, Linhong Wang, Yufei Liu, Renyu Li, Min Gao, Fuping |
author_facet | He, Jinfeng Zhang, Xuanping Liu, Linhong Wang, Yufei Liu, Renyu Li, Min Gao, Fuping |
author_sort | He, Jinfeng |
collection | PubMed |
description | Boron nitride nanoparticles have been reported for boron drug delivery. However, its toxicity has not been systematically elucidated. It is necessary to clarify their potential toxicity profile after administration for clinical application. Here, we prepared erythrocyte membrane-coated boron nitride nanoparticles (BN@RBCM). We expect to use them for boron neutron capture therapy (BNCT) in tumors. In this study, we evaluated the acute toxicity and subacute toxicity of BN@RBCM of about 100 nm and determined the half-lethal dose (LD50) of the particles for mice. The results showed that the LD50 of BN@RBCM was 258.94 mg/kg. No remarkable pathological changes by microscopic observation were observed in the treated animals throughout the study period. These results indicate that BN@RBCM has low toxicity and good biocompatibility, which have great potential for biomedical applications. |
format | Online Article Text |
id | pubmed-10144386 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-101443862023-04-29 Acute and Subacute Toxicity Evaluation of Erythrocyte Membrane-Coated Boron Nitride Nanoparticles He, Jinfeng Zhang, Xuanping Liu, Linhong Wang, Yufei Liu, Renyu Li, Min Gao, Fuping J Funct Biomater Article Boron nitride nanoparticles have been reported for boron drug delivery. However, its toxicity has not been systematically elucidated. It is necessary to clarify their potential toxicity profile after administration for clinical application. Here, we prepared erythrocyte membrane-coated boron nitride nanoparticles (BN@RBCM). We expect to use them for boron neutron capture therapy (BNCT) in tumors. In this study, we evaluated the acute toxicity and subacute toxicity of BN@RBCM of about 100 nm and determined the half-lethal dose (LD50) of the particles for mice. The results showed that the LD50 of BN@RBCM was 258.94 mg/kg. No remarkable pathological changes by microscopic observation were observed in the treated animals throughout the study period. These results indicate that BN@RBCM has low toxicity and good biocompatibility, which have great potential for biomedical applications. MDPI 2023-03-25 /pmc/articles/PMC10144386/ /pubmed/37103271 http://dx.doi.org/10.3390/jfb14040181 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article He, Jinfeng Zhang, Xuanping Liu, Linhong Wang, Yufei Liu, Renyu Li, Min Gao, Fuping Acute and Subacute Toxicity Evaluation of Erythrocyte Membrane-Coated Boron Nitride Nanoparticles |
title | Acute and Subacute Toxicity Evaluation of Erythrocyte Membrane-Coated Boron Nitride Nanoparticles |
title_full | Acute and Subacute Toxicity Evaluation of Erythrocyte Membrane-Coated Boron Nitride Nanoparticles |
title_fullStr | Acute and Subacute Toxicity Evaluation of Erythrocyte Membrane-Coated Boron Nitride Nanoparticles |
title_full_unstemmed | Acute and Subacute Toxicity Evaluation of Erythrocyte Membrane-Coated Boron Nitride Nanoparticles |
title_short | Acute and Subacute Toxicity Evaluation of Erythrocyte Membrane-Coated Boron Nitride Nanoparticles |
title_sort | acute and subacute toxicity evaluation of erythrocyte membrane-coated boron nitride nanoparticles |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10144386/ https://www.ncbi.nlm.nih.gov/pubmed/37103271 http://dx.doi.org/10.3390/jfb14040181 |
work_keys_str_mv | AT hejinfeng acuteandsubacutetoxicityevaluationoferythrocytemembranecoatedboronnitridenanoparticles AT zhangxuanping acuteandsubacutetoxicityevaluationoferythrocytemembranecoatedboronnitridenanoparticles AT liulinhong acuteandsubacutetoxicityevaluationoferythrocytemembranecoatedboronnitridenanoparticles AT wangyufei acuteandsubacutetoxicityevaluationoferythrocytemembranecoatedboronnitridenanoparticles AT liurenyu acuteandsubacutetoxicityevaluationoferythrocytemembranecoatedboronnitridenanoparticles AT limin acuteandsubacutetoxicityevaluationoferythrocytemembranecoatedboronnitridenanoparticles AT gaofuping acuteandsubacutetoxicityevaluationoferythrocytemembranecoatedboronnitridenanoparticles |