Cargando…

High Dosage of Patient-Controlled Epidural Analgesia (PCEA) with Low Background Infusion during Labor: A Randomized Controlled Trial

Background: Patient-controlled epidural analgesia (PCEA) is well documented; however, it is unclear whether a high dosage of PCEA with a low dosage of background infusion during labor can be a safe and effective application. Methods: Group LH was administered a continuous infusion (CI) of 0.084 mL/k...

Descripción completa

Detalles Bibliográficos
Autores principales: Wei, Yu, Wang, Yilong, Zhao, Yanhong, Wu, Chaomin, Liu, Henry, Yang, Zeyong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10144857/
https://www.ncbi.nlm.nih.gov/pubmed/37108986
http://dx.doi.org/10.3390/jpm13040600
_version_ 1785034194596921344
author Wei, Yu
Wang, Yilong
Zhao, Yanhong
Wu, Chaomin
Liu, Henry
Yang, Zeyong
author_facet Wei, Yu
Wang, Yilong
Zhao, Yanhong
Wu, Chaomin
Liu, Henry
Yang, Zeyong
author_sort Wei, Yu
collection PubMed
description Background: Patient-controlled epidural analgesia (PCEA) is well documented; however, it is unclear whether a high dosage of PCEA with a low dosage of background infusion during labor can be a safe and effective application. Methods: Group LH was administered a continuous infusion (CI) of 0.084 mL/kg/h with PCEA of 5 mL every 40 min. Group HL was given a CI of 0.028 mL/kg/h and PCEA of 10 mL every 40 min; Group HH was given a CI of 0.084 mL/kg/h and PCEA of 10 mL every 40 min. The primary outcomes were VAS pain score, the number of supplemental boluses, incidence of pain outbreaks, drug dose for pain outbreaks, PCA times, effective PCA times, anesthetic consumption, duration of analgesia, duration of labor and delivery outcome. Secondary outcomes included adverse reactions such as itching, nausea and vomiting during analgesia and neonatal Apgar scores 1 min and 5 min after birth. Results: A total of 180 patients, 60 in each group were randomly assigned to one of three groups included group LH, group HL or group HH. The VAS scores were obviously decreased in HL group and HH group in comparison with LL group at 2 h after analgesia and the time point of full cervical dilation and delivery of baby. The time for third stage of labor in HH group was increased compared with LH group and HL group. Incidence of pain outbreaks in LH group was obviously increased compared with HL and HH group. The effective PCA times in HL group and HH group were remarkably reduced compared with those in LH group. Conclusions: High dose of PCEA with a low background infusion can reduce effective PCA times, incidence of outbreak pain and the total amount of anesthetics without diminishing analgesia effects. However, high dose of PCEA with a high background infusion can enhance analgesia effect but increase the third stage of labor, instrumental delivery ratio and the total amount of anesthetics.
format Online
Article
Text
id pubmed-10144857
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-101448572023-04-29 High Dosage of Patient-Controlled Epidural Analgesia (PCEA) with Low Background Infusion during Labor: A Randomized Controlled Trial Wei, Yu Wang, Yilong Zhao, Yanhong Wu, Chaomin Liu, Henry Yang, Zeyong J Pers Med Article Background: Patient-controlled epidural analgesia (PCEA) is well documented; however, it is unclear whether a high dosage of PCEA with a low dosage of background infusion during labor can be a safe and effective application. Methods: Group LH was administered a continuous infusion (CI) of 0.084 mL/kg/h with PCEA of 5 mL every 40 min. Group HL was given a CI of 0.028 mL/kg/h and PCEA of 10 mL every 40 min; Group HH was given a CI of 0.084 mL/kg/h and PCEA of 10 mL every 40 min. The primary outcomes were VAS pain score, the number of supplemental boluses, incidence of pain outbreaks, drug dose for pain outbreaks, PCA times, effective PCA times, anesthetic consumption, duration of analgesia, duration of labor and delivery outcome. Secondary outcomes included adverse reactions such as itching, nausea and vomiting during analgesia and neonatal Apgar scores 1 min and 5 min after birth. Results: A total of 180 patients, 60 in each group were randomly assigned to one of three groups included group LH, group HL or group HH. The VAS scores were obviously decreased in HL group and HH group in comparison with LL group at 2 h after analgesia and the time point of full cervical dilation and delivery of baby. The time for third stage of labor in HH group was increased compared with LH group and HL group. Incidence of pain outbreaks in LH group was obviously increased compared with HL and HH group. The effective PCA times in HL group and HH group were remarkably reduced compared with those in LH group. Conclusions: High dose of PCEA with a low background infusion can reduce effective PCA times, incidence of outbreak pain and the total amount of anesthetics without diminishing analgesia effects. However, high dose of PCEA with a high background infusion can enhance analgesia effect but increase the third stage of labor, instrumental delivery ratio and the total amount of anesthetics. MDPI 2023-03-29 /pmc/articles/PMC10144857/ /pubmed/37108986 http://dx.doi.org/10.3390/jpm13040600 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Wei, Yu
Wang, Yilong
Zhao, Yanhong
Wu, Chaomin
Liu, Henry
Yang, Zeyong
High Dosage of Patient-Controlled Epidural Analgesia (PCEA) with Low Background Infusion during Labor: A Randomized Controlled Trial
title High Dosage of Patient-Controlled Epidural Analgesia (PCEA) with Low Background Infusion during Labor: A Randomized Controlled Trial
title_full High Dosage of Patient-Controlled Epidural Analgesia (PCEA) with Low Background Infusion during Labor: A Randomized Controlled Trial
title_fullStr High Dosage of Patient-Controlled Epidural Analgesia (PCEA) with Low Background Infusion during Labor: A Randomized Controlled Trial
title_full_unstemmed High Dosage of Patient-Controlled Epidural Analgesia (PCEA) with Low Background Infusion during Labor: A Randomized Controlled Trial
title_short High Dosage of Patient-Controlled Epidural Analgesia (PCEA) with Low Background Infusion during Labor: A Randomized Controlled Trial
title_sort high dosage of patient-controlled epidural analgesia (pcea) with low background infusion during labor: a randomized controlled trial
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10144857/
https://www.ncbi.nlm.nih.gov/pubmed/37108986
http://dx.doi.org/10.3390/jpm13040600
work_keys_str_mv AT weiyu highdosageofpatientcontrolledepiduralanalgesiapceawithlowbackgroundinfusionduringlaborarandomizedcontrolledtrial
AT wangyilong highdosageofpatientcontrolledepiduralanalgesiapceawithlowbackgroundinfusionduringlaborarandomizedcontrolledtrial
AT zhaoyanhong highdosageofpatientcontrolledepiduralanalgesiapceawithlowbackgroundinfusionduringlaborarandomizedcontrolledtrial
AT wuchaomin highdosageofpatientcontrolledepiduralanalgesiapceawithlowbackgroundinfusionduringlaborarandomizedcontrolledtrial
AT liuhenry highdosageofpatientcontrolledepiduralanalgesiapceawithlowbackgroundinfusionduringlaborarandomizedcontrolledtrial
AT yangzeyong highdosageofpatientcontrolledepiduralanalgesiapceawithlowbackgroundinfusionduringlaborarandomizedcontrolledtrial