An Open-Source, Interoperable Architecture for Generating Real-Time Surgical Team Cognitive Alerts from Heart-Rate Variability Monitoring

Clinical alarm and decision support systems that lack clinical context may create non-actionable nuisance alarms that are not clinically relevant and can cause distractions during the most difficult moments of a surgery. We present a novel, interoperable, real-time system for adding contextual aware...

Descripción completa

Detalles Bibliográficos
Autores principales: Arney, David, Zhang, Yi, Kennedy-Metz, Lauren R., Dias, Roger D., Goldman, Julian M., Zenati, Marco A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10145698/
https://www.ncbi.nlm.nih.gov/pubmed/37112231
http://dx.doi.org/10.3390/s23083890
_version_ 1785034399473991680
author Arney, David
Zhang, Yi
Kennedy-Metz, Lauren R.
Dias, Roger D.
Goldman, Julian M.
Zenati, Marco A.
author_facet Arney, David
Zhang, Yi
Kennedy-Metz, Lauren R.
Dias, Roger D.
Goldman, Julian M.
Zenati, Marco A.
author_sort Arney, David
collection PubMed
description Clinical alarm and decision support systems that lack clinical context may create non-actionable nuisance alarms that are not clinically relevant and can cause distractions during the most difficult moments of a surgery. We present a novel, interoperable, real-time system for adding contextual awareness to clinical systems by monitoring the heart-rate variability (HRV) of clinical team members. We designed an architecture for real-time capture, analysis, and presentation of HRV data from multiple clinicians and implemented this architecture as an application and device interfaces on the open-source OpenICE interoperability platform. In this work, we extend OpenICE with new capabilities to support the needs of the context-aware OR including a modularized data pipeline for simultaneously processing real-time electrocardiographic (ECG) waveforms from multiple clinicians to create estimates of their individual cognitive load. The system is built with standardized interfaces that allow for free interchange of software and hardware components including sensor devices, ECG filtering and beat detection algorithms, HRV metric calculations, and individual and team alerts based on changes in metrics. By integrating contextual cues and team member state into a unified process model, we believe future clinical applications will be able to emulate some of these behaviors to provide context-aware information to improve the safety and quality of surgical interventions.
format Online
Article
Text
id pubmed-10145698
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-101456982023-04-29 An Open-Source, Interoperable Architecture for Generating Real-Time Surgical Team Cognitive Alerts from Heart-Rate Variability Monitoring Arney, David Zhang, Yi Kennedy-Metz, Lauren R. Dias, Roger D. Goldman, Julian M. Zenati, Marco A. Sensors (Basel) Article Clinical alarm and decision support systems that lack clinical context may create non-actionable nuisance alarms that are not clinically relevant and can cause distractions during the most difficult moments of a surgery. We present a novel, interoperable, real-time system for adding contextual awareness to clinical systems by monitoring the heart-rate variability (HRV) of clinical team members. We designed an architecture for real-time capture, analysis, and presentation of HRV data from multiple clinicians and implemented this architecture as an application and device interfaces on the open-source OpenICE interoperability platform. In this work, we extend OpenICE with new capabilities to support the needs of the context-aware OR including a modularized data pipeline for simultaneously processing real-time electrocardiographic (ECG) waveforms from multiple clinicians to create estimates of their individual cognitive load. The system is built with standardized interfaces that allow for free interchange of software and hardware components including sensor devices, ECG filtering and beat detection algorithms, HRV metric calculations, and individual and team alerts based on changes in metrics. By integrating contextual cues and team member state into a unified process model, we believe future clinical applications will be able to emulate some of these behaviors to provide context-aware information to improve the safety and quality of surgical interventions. MDPI 2023-04-11 /pmc/articles/PMC10145698/ /pubmed/37112231 http://dx.doi.org/10.3390/s23083890 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Arney, David
Zhang, Yi
Kennedy-Metz, Lauren R.
Dias, Roger D.
Goldman, Julian M.
Zenati, Marco A.
An Open-Source, Interoperable Architecture for Generating Real-Time Surgical Team Cognitive Alerts from Heart-Rate Variability Monitoring
title An Open-Source, Interoperable Architecture for Generating Real-Time Surgical Team Cognitive Alerts from Heart-Rate Variability Monitoring
title_full An Open-Source, Interoperable Architecture for Generating Real-Time Surgical Team Cognitive Alerts from Heart-Rate Variability Monitoring
title_fullStr An Open-Source, Interoperable Architecture for Generating Real-Time Surgical Team Cognitive Alerts from Heart-Rate Variability Monitoring
title_full_unstemmed An Open-Source, Interoperable Architecture for Generating Real-Time Surgical Team Cognitive Alerts from Heart-Rate Variability Monitoring
title_short An Open-Source, Interoperable Architecture for Generating Real-Time Surgical Team Cognitive Alerts from Heart-Rate Variability Monitoring
title_sort open-source, interoperable architecture for generating real-time surgical team cognitive alerts from heart-rate variability monitoring
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10145698/
https://www.ncbi.nlm.nih.gov/pubmed/37112231
http://dx.doi.org/10.3390/s23083890
work_keys_str_mv AT arneydavid anopensourceinteroperablearchitectureforgeneratingrealtimesurgicalteamcognitivealertsfromheartratevariabilitymonitoring
AT zhangyi anopensourceinteroperablearchitectureforgeneratingrealtimesurgicalteamcognitivealertsfromheartratevariabilitymonitoring
AT kennedymetzlaurenr anopensourceinteroperablearchitectureforgeneratingrealtimesurgicalteamcognitivealertsfromheartratevariabilitymonitoring
AT diasrogerd anopensourceinteroperablearchitectureforgeneratingrealtimesurgicalteamcognitivealertsfromheartratevariabilitymonitoring
AT goldmanjulianm anopensourceinteroperablearchitectureforgeneratingrealtimesurgicalteamcognitivealertsfromheartratevariabilitymonitoring
AT zenatimarcoa anopensourceinteroperablearchitectureforgeneratingrealtimesurgicalteamcognitivealertsfromheartratevariabilitymonitoring
AT arneydavid opensourceinteroperablearchitectureforgeneratingrealtimesurgicalteamcognitivealertsfromheartratevariabilitymonitoring
AT zhangyi opensourceinteroperablearchitectureforgeneratingrealtimesurgicalteamcognitivealertsfromheartratevariabilitymonitoring
AT kennedymetzlaurenr opensourceinteroperablearchitectureforgeneratingrealtimesurgicalteamcognitivealertsfromheartratevariabilitymonitoring
AT diasrogerd opensourceinteroperablearchitectureforgeneratingrealtimesurgicalteamcognitivealertsfromheartratevariabilitymonitoring
AT goldmanjulianm opensourceinteroperablearchitectureforgeneratingrealtimesurgicalteamcognitivealertsfromheartratevariabilitymonitoring
AT zenatimarcoa opensourceinteroperablearchitectureforgeneratingrealtimesurgicalteamcognitivealertsfromheartratevariabilitymonitoring