Cargando…
Rapid Elution of (226)Th from a Two-Column (230)U/(226)Th Generator with Diluted and Buffer Solutions
A radionuclide generator of the short-lived alpha emitter (226)Th was proposed. An original scheme consisting of two in-series chromatographic columns was developed for rapidly producing a neutral citric-buffered eluate of high purity (226)Th. The first column filled with TEVA resin retained the par...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
MDPI
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10146531/ https://www.ncbi.nlm.nih.gov/pubmed/37110782 http://dx.doi.org/10.3390/molecules28083548 |
_version_ | 1785034601817702400 |
---|---|
author | Ermolaev, Stanislav V. Skasyrskaya, Aino K. Vasiliev, Aleksandr N. |
author_facet | Ermolaev, Stanislav V. Skasyrskaya, Aino K. Vasiliev, Aleksandr N. |
author_sort | Ermolaev, Stanislav V. |
collection | PubMed |
description | A radionuclide generator of the short-lived alpha emitter (226)Th was proposed. An original scheme consisting of two in-series chromatographic columns was developed for rapidly producing a neutral citric-buffered eluate of high purity (226)Th. The first column filled with TEVA resin retained the parent (230)U, while (226)Th was eluted with 7 M HCl solution to be immediately adsorbed on the second column containing DGA resin or UTEVA resin. Having substituted the strongly acidic medium of second column with neutral salt solution, (226)Th was desorbed with diluted citric buffer solution. One cycle of generator milking took 5–7 min and produced >90% of (226)Th in 1.5 mL of eluate (pH 4.5–5.0) appropriate for direct use in radiopharmaceutical synthesis. The (230)U impurity in (226)Th eluate was less than 0.01%. The proposed two-column (230)U/(226)Th generator was tested over 2 months including a second loading of (230)U additionally accumulated from (230)Pa. |
format | Online Article Text |
id | pubmed-10146531 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | MDPI |
record_format | MEDLINE/PubMed |
spelling | pubmed-101465312023-04-29 Rapid Elution of (226)Th from a Two-Column (230)U/(226)Th Generator with Diluted and Buffer Solutions Ermolaev, Stanislav V. Skasyrskaya, Aino K. Vasiliev, Aleksandr N. Molecules Article A radionuclide generator of the short-lived alpha emitter (226)Th was proposed. An original scheme consisting of two in-series chromatographic columns was developed for rapidly producing a neutral citric-buffered eluate of high purity (226)Th. The first column filled with TEVA resin retained the parent (230)U, while (226)Th was eluted with 7 M HCl solution to be immediately adsorbed on the second column containing DGA resin or UTEVA resin. Having substituted the strongly acidic medium of second column with neutral salt solution, (226)Th was desorbed with diluted citric buffer solution. One cycle of generator milking took 5–7 min and produced >90% of (226)Th in 1.5 mL of eluate (pH 4.5–5.0) appropriate for direct use in radiopharmaceutical synthesis. The (230)U impurity in (226)Th eluate was less than 0.01%. The proposed two-column (230)U/(226)Th generator was tested over 2 months including a second loading of (230)U additionally accumulated from (230)Pa. MDPI 2023-04-18 /pmc/articles/PMC10146531/ /pubmed/37110782 http://dx.doi.org/10.3390/molecules28083548 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/). |
spellingShingle | Article Ermolaev, Stanislav V. Skasyrskaya, Aino K. Vasiliev, Aleksandr N. Rapid Elution of (226)Th from a Two-Column (230)U/(226)Th Generator with Diluted and Buffer Solutions |
title | Rapid Elution of (226)Th from a Two-Column (230)U/(226)Th Generator with Diluted and Buffer Solutions |
title_full | Rapid Elution of (226)Th from a Two-Column (230)U/(226)Th Generator with Diluted and Buffer Solutions |
title_fullStr | Rapid Elution of (226)Th from a Two-Column (230)U/(226)Th Generator with Diluted and Buffer Solutions |
title_full_unstemmed | Rapid Elution of (226)Th from a Two-Column (230)U/(226)Th Generator with Diluted and Buffer Solutions |
title_short | Rapid Elution of (226)Th from a Two-Column (230)U/(226)Th Generator with Diluted and Buffer Solutions |
title_sort | rapid elution of (226)th from a two-column (230)u/(226)th generator with diluted and buffer solutions |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10146531/ https://www.ncbi.nlm.nih.gov/pubmed/37110782 http://dx.doi.org/10.3390/molecules28083548 |
work_keys_str_mv | AT ermolaevstanislavv rapidelutionof226thfromatwocolumn230u226thgeneratorwithdilutedandbuffersolutions AT skasyrskayaainok rapidelutionof226thfromatwocolumn230u226thgeneratorwithdilutedandbuffersolutions AT vasilievaleksandrn rapidelutionof226thfromatwocolumn230u226thgeneratorwithdilutedandbuffersolutions |