Cargando…
Experimental investigation of the parameters that affect droplet size and distribution for design calculations of two-phase separators
The critical design parameter when sizing a separator is the size of oil droplets in the water phase. This study improves the design of a separator by investigating the parameters that control droplet size, frequency, and distribution. Experimental work was performed to investigate the effect of flo...
Autores principales: | Pun, Kul, Hamad, Faik, Ahmed, Tariq, Ugwu, Johnson, Najim, Safa, Eyers, James, Lawson, Gary, Russell, Paul |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10147983/ https://www.ncbi.nlm.nih.gov/pubmed/37128334 http://dx.doi.org/10.1016/j.heliyon.2023.e15397 |