Cargando…
Simplified Meal Announcement Versus Precise Carbohydrate Counting in Adolescents With Type 1 Diabetes Using the MiniMed 780G Advanced Hybrid Closed Loop System: A Randomized Controlled Trial Comparing Glucose Control
OBJECTIVE: We aimed to compare glucose control in adolescents with type 1 diabetes (T1D) using the MiniMed 780G system who used simplified meal announcement with those who used precise carbohydrate counting. RESEARCH DESIGN AND METHODS: This randomized controlled trial included 34 participants (age...
Autores principales: | , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
American Diabetes Association
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10148675/ https://www.ncbi.nlm.nih.gov/pubmed/36598841 http://dx.doi.org/10.2337/dc22-1692 |
_version_ | 1785035024229203968 |
---|---|
author | Petrovski, Goran Campbell, Judith Pasha, Maheen Day, Emma Hussain, Khalid Khalifa, Amel van den Heuvel, Tim |
author_facet | Petrovski, Goran Campbell, Judith Pasha, Maheen Day, Emma Hussain, Khalid Khalifa, Amel van den Heuvel, Tim |
author_sort | Petrovski, Goran |
collection | PubMed |
description | OBJECTIVE: We aimed to compare glucose control in adolescents with type 1 diabetes (T1D) using the MiniMed 780G system who used simplified meal announcement with those who used precise carbohydrate counting. RESEARCH DESIGN AND METHODS: This randomized controlled trial included 34 participants (age 12–18 years) with T1D who were on multiple daily injections or insulin pump and were scheduled to start using the MiniMed 780G system at Sidra Medicine in Qatar. After a 7-day run-in period, participants were randomly assigned to the fix group (simplified meal announcement by preset of three personalized fixed carbohydrate amounts) or the flex group (precise carbohydrate counting) and followed for 12 weeks. Between-group difference in time in range (TIR) was the primary end point. Secondary end points included HbA(1c) and other glycometrics. RESULTS: During the 12-week study phase, TIR was 73.5 ± 6.7% in the fix and 80.3 ± 7.4% in the flex group, with a between-group difference of 6.8% in favor of flex (P = 0.043). Time >250 mg/dL was better in the flex group (P = 0.012), whereas HbA(1c) (P = 0.168), time below range (P = 0.283), and time between 180 and 250 mg/dL (P = 0.114) did not differ. CONCLUSIONS: Adolescents using the MiniMed 780G system with a preset of three personalized fixed carbohydrate amounts can reach international targets of glycemic control. Therefore, it may be a valuable alternative to precise carbohydrate counting in users who are challenged by precise carbohydrate counting. Because carbohydrate counting further improves outcomes, these skills remain important for MiniMed 780G users. |
format | Online Article Text |
id | pubmed-10148675 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | American Diabetes Association |
record_format | MEDLINE/PubMed |
spelling | pubmed-101486752023-04-30 Simplified Meal Announcement Versus Precise Carbohydrate Counting in Adolescents With Type 1 Diabetes Using the MiniMed 780G Advanced Hybrid Closed Loop System: A Randomized Controlled Trial Comparing Glucose Control Petrovski, Goran Campbell, Judith Pasha, Maheen Day, Emma Hussain, Khalid Khalifa, Amel van den Heuvel, Tim Diabetes Care Original Article OBJECTIVE: We aimed to compare glucose control in adolescents with type 1 diabetes (T1D) using the MiniMed 780G system who used simplified meal announcement with those who used precise carbohydrate counting. RESEARCH DESIGN AND METHODS: This randomized controlled trial included 34 participants (age 12–18 years) with T1D who were on multiple daily injections or insulin pump and were scheduled to start using the MiniMed 780G system at Sidra Medicine in Qatar. After a 7-day run-in period, participants were randomly assigned to the fix group (simplified meal announcement by preset of three personalized fixed carbohydrate amounts) or the flex group (precise carbohydrate counting) and followed for 12 weeks. Between-group difference in time in range (TIR) was the primary end point. Secondary end points included HbA(1c) and other glycometrics. RESULTS: During the 12-week study phase, TIR was 73.5 ± 6.7% in the fix and 80.3 ± 7.4% in the flex group, with a between-group difference of 6.8% in favor of flex (P = 0.043). Time >250 mg/dL was better in the flex group (P = 0.012), whereas HbA(1c) (P = 0.168), time below range (P = 0.283), and time between 180 and 250 mg/dL (P = 0.114) did not differ. CONCLUSIONS: Adolescents using the MiniMed 780G system with a preset of three personalized fixed carbohydrate amounts can reach international targets of glycemic control. Therefore, it may be a valuable alternative to precise carbohydrate counting in users who are challenged by precise carbohydrate counting. Because carbohydrate counting further improves outcomes, these skills remain important for MiniMed 780G users. American Diabetes Association 2023-03 2023-01-04 /pmc/articles/PMC10148675/ /pubmed/36598841 http://dx.doi.org/10.2337/dc22-1692 Text en © 2023 by the American Diabetes Association https://www.diabetesjournals.org/journals/pages/licenseReaders may use this article as long as the work is properly cited, the use is educational and not for profit, and the work is not altered. More information is available at https://www.diabetesjournals.org/journals/pages/license. |
spellingShingle | Original Article Petrovski, Goran Campbell, Judith Pasha, Maheen Day, Emma Hussain, Khalid Khalifa, Amel van den Heuvel, Tim Simplified Meal Announcement Versus Precise Carbohydrate Counting in Adolescents With Type 1 Diabetes Using the MiniMed 780G Advanced Hybrid Closed Loop System: A Randomized Controlled Trial Comparing Glucose Control |
title | Simplified Meal Announcement Versus Precise Carbohydrate Counting in Adolescents With Type 1 Diabetes Using the MiniMed 780G Advanced Hybrid Closed Loop System: A Randomized Controlled Trial Comparing Glucose Control |
title_full | Simplified Meal Announcement Versus Precise Carbohydrate Counting in Adolescents With Type 1 Diabetes Using the MiniMed 780G Advanced Hybrid Closed Loop System: A Randomized Controlled Trial Comparing Glucose Control |
title_fullStr | Simplified Meal Announcement Versus Precise Carbohydrate Counting in Adolescents With Type 1 Diabetes Using the MiniMed 780G Advanced Hybrid Closed Loop System: A Randomized Controlled Trial Comparing Glucose Control |
title_full_unstemmed | Simplified Meal Announcement Versus Precise Carbohydrate Counting in Adolescents With Type 1 Diabetes Using the MiniMed 780G Advanced Hybrid Closed Loop System: A Randomized Controlled Trial Comparing Glucose Control |
title_short | Simplified Meal Announcement Versus Precise Carbohydrate Counting in Adolescents With Type 1 Diabetes Using the MiniMed 780G Advanced Hybrid Closed Loop System: A Randomized Controlled Trial Comparing Glucose Control |
title_sort | simplified meal announcement versus precise carbohydrate counting in adolescents with type 1 diabetes using the minimed 780g advanced hybrid closed loop system: a randomized controlled trial comparing glucose control |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10148675/ https://www.ncbi.nlm.nih.gov/pubmed/36598841 http://dx.doi.org/10.2337/dc22-1692 |
work_keys_str_mv | AT petrovskigoran simplifiedmealannouncementversusprecisecarbohydratecountinginadolescentswithtype1diabetesusingtheminimed780gadvancedhybridclosedloopsystemarandomizedcontrolledtrialcomparingglucosecontrol AT campbelljudith simplifiedmealannouncementversusprecisecarbohydratecountinginadolescentswithtype1diabetesusingtheminimed780gadvancedhybridclosedloopsystemarandomizedcontrolledtrialcomparingglucosecontrol AT pashamaheen simplifiedmealannouncementversusprecisecarbohydratecountinginadolescentswithtype1diabetesusingtheminimed780gadvancedhybridclosedloopsystemarandomizedcontrolledtrialcomparingglucosecontrol AT dayemma simplifiedmealannouncementversusprecisecarbohydratecountinginadolescentswithtype1diabetesusingtheminimed780gadvancedhybridclosedloopsystemarandomizedcontrolledtrialcomparingglucosecontrol AT hussainkhalid simplifiedmealannouncementversusprecisecarbohydratecountinginadolescentswithtype1diabetesusingtheminimed780gadvancedhybridclosedloopsystemarandomizedcontrolledtrialcomparingglucosecontrol AT khalifaamel simplifiedmealannouncementversusprecisecarbohydratecountinginadolescentswithtype1diabetesusingtheminimed780gadvancedhybridclosedloopsystemarandomizedcontrolledtrialcomparingglucosecontrol AT vandenheuveltim simplifiedmealannouncementversusprecisecarbohydratecountinginadolescentswithtype1diabetesusingtheminimed780gadvancedhybridclosedloopsystemarandomizedcontrolledtrialcomparingglucosecontrol |