Cargando…

Comprehensive two-dimensional gas chromatography with flow modulator coupled via tube plasma ionization to an atmospheric pressure high-resolution mass spectrometer for the analysis of vermouth volatile profile

The analysis of complex samples is a big analytical challenge due to the vast number of compounds present in these samples as well as the influence matrix components could cause in the methodology. In this way, comprehensive two-dimensional gas chromatography coupled to mass spectrometry (GC × GC–MS...

Descripción completa

Detalles Bibliográficos
Autores principales: Ayala-Cabrera, Juan F., Montero, Lidia, Sahlabji, Taher, Schmitz, Oliver J.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10149472/
https://www.ncbi.nlm.nih.gov/pubmed/37059842
http://dx.doi.org/10.1007/s00216-023-04688-6
_version_ 1785035169151844352
author Ayala-Cabrera, Juan F.
Montero, Lidia
Sahlabji, Taher
Schmitz, Oliver J.
author_facet Ayala-Cabrera, Juan F.
Montero, Lidia
Sahlabji, Taher
Schmitz, Oliver J.
author_sort Ayala-Cabrera, Juan F.
collection PubMed
description The analysis of complex samples is a big analytical challenge due to the vast number of compounds present in these samples as well as the influence matrix components could cause in the methodology. In this way, comprehensive two-dimensional gas chromatography coupled to mass spectrometry (GC × GC–MS) is a very powerful tool to achieve the characterization of complex samples. Nevertheless, due to possible coelutions occurring in these matrices, mixed spectra are generally obtained with electron ionization (EI) which could extremely complicate the identification of the analytes. Thereby, new methodology setups are required to improve the confidence on the identification in non-targeted determinations. Here, we present a high-throughput methodology consisting of GC × GC with flow modulation coupled to high-resolution atmospheric pressure mass spectrometry (HRMS) via a novel tube plasma ion source (TPI). The flow modulator allows to easily automate the GC × GC method compared to traditional cryo-modulators, while the soft ionization provided by TPI helps to preserve the [M](+•) or [M+H](+) ions, thus increasing the confidence in the identification. Additionally, the combination of a flow modulation with an atmospheric pressure mass spectrometer significantly improves the sensitivity over flow modulated GC × GC-EI-MS methods because no split is required. This methodology was applied to the analysis of a complex sample such as vermouth where the volatile profile is usually considered by consumers as a product quality indicator since it raises the first sensations produced during its consumption. Using this approach, different classes of compounds were tentatively identified in the sample, including monoterpenes, terpenoids, sesquiterpenoids and carboxylic acid, and carboxylate esters among others, showing the great potential of a GC × GC-TPI-qTOF-MS platform for improving the confidence of the identifications in non-targeted applications. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00216-023-04688-6.
format Online
Article
Text
id pubmed-10149472
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-101494722023-05-02 Comprehensive two-dimensional gas chromatography with flow modulator coupled via tube plasma ionization to an atmospheric pressure high-resolution mass spectrometer for the analysis of vermouth volatile profile Ayala-Cabrera, Juan F. Montero, Lidia Sahlabji, Taher Schmitz, Oliver J. Anal Bioanal Chem Research Paper The analysis of complex samples is a big analytical challenge due to the vast number of compounds present in these samples as well as the influence matrix components could cause in the methodology. In this way, comprehensive two-dimensional gas chromatography coupled to mass spectrometry (GC × GC–MS) is a very powerful tool to achieve the characterization of complex samples. Nevertheless, due to possible coelutions occurring in these matrices, mixed spectra are generally obtained with electron ionization (EI) which could extremely complicate the identification of the analytes. Thereby, new methodology setups are required to improve the confidence on the identification in non-targeted determinations. Here, we present a high-throughput methodology consisting of GC × GC with flow modulation coupled to high-resolution atmospheric pressure mass spectrometry (HRMS) via a novel tube plasma ion source (TPI). The flow modulator allows to easily automate the GC × GC method compared to traditional cryo-modulators, while the soft ionization provided by TPI helps to preserve the [M](+•) or [M+H](+) ions, thus increasing the confidence in the identification. Additionally, the combination of a flow modulation with an atmospheric pressure mass spectrometer significantly improves the sensitivity over flow modulated GC × GC-EI-MS methods because no split is required. This methodology was applied to the analysis of a complex sample such as vermouth where the volatile profile is usually considered by consumers as a product quality indicator since it raises the first sensations produced during its consumption. Using this approach, different classes of compounds were tentatively identified in the sample, including monoterpenes, terpenoids, sesquiterpenoids and carboxylic acid, and carboxylate esters among others, showing the great potential of a GC × GC-TPI-qTOF-MS platform for improving the confidence of the identifications in non-targeted applications. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00216-023-04688-6. Springer Berlin Heidelberg 2023-04-15 2023 /pmc/articles/PMC10149472/ /pubmed/37059842 http://dx.doi.org/10.1007/s00216-023-04688-6 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Research Paper
Ayala-Cabrera, Juan F.
Montero, Lidia
Sahlabji, Taher
Schmitz, Oliver J.
Comprehensive two-dimensional gas chromatography with flow modulator coupled via tube plasma ionization to an atmospheric pressure high-resolution mass spectrometer for the analysis of vermouth volatile profile
title Comprehensive two-dimensional gas chromatography with flow modulator coupled via tube plasma ionization to an atmospheric pressure high-resolution mass spectrometer for the analysis of vermouth volatile profile
title_full Comprehensive two-dimensional gas chromatography with flow modulator coupled via tube plasma ionization to an atmospheric pressure high-resolution mass spectrometer for the analysis of vermouth volatile profile
title_fullStr Comprehensive two-dimensional gas chromatography with flow modulator coupled via tube plasma ionization to an atmospheric pressure high-resolution mass spectrometer for the analysis of vermouth volatile profile
title_full_unstemmed Comprehensive two-dimensional gas chromatography with flow modulator coupled via tube plasma ionization to an atmospheric pressure high-resolution mass spectrometer for the analysis of vermouth volatile profile
title_short Comprehensive two-dimensional gas chromatography with flow modulator coupled via tube plasma ionization to an atmospheric pressure high-resolution mass spectrometer for the analysis of vermouth volatile profile
title_sort comprehensive two-dimensional gas chromatography with flow modulator coupled via tube plasma ionization to an atmospheric pressure high-resolution mass spectrometer for the analysis of vermouth volatile profile
topic Research Paper
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10149472/
https://www.ncbi.nlm.nih.gov/pubmed/37059842
http://dx.doi.org/10.1007/s00216-023-04688-6
work_keys_str_mv AT ayalacabrerajuanf comprehensivetwodimensionalgaschromatographywithflowmodulatorcoupledviatubeplasmaionizationtoanatmosphericpressurehighresolutionmassspectrometerfortheanalysisofvermouthvolatileprofile
AT monterolidia comprehensivetwodimensionalgaschromatographywithflowmodulatorcoupledviatubeplasmaionizationtoanatmosphericpressurehighresolutionmassspectrometerfortheanalysisofvermouthvolatileprofile
AT sahlabjitaher comprehensivetwodimensionalgaschromatographywithflowmodulatorcoupledviatubeplasmaionizationtoanatmosphericpressurehighresolutionmassspectrometerfortheanalysisofvermouthvolatileprofile
AT schmitzoliverj comprehensivetwodimensionalgaschromatographywithflowmodulatorcoupledviatubeplasmaionizationtoanatmosphericpressurehighresolutionmassspectrometerfortheanalysisofvermouthvolatileprofile