Cargando…

Validation of attenuation imaging coefficient, shear wave elastography, and dispersion as emerging tools for non-invasive evaluation of liver tissue in children

INTRODUCTION: The number of children with acute and chronic liver disease is rising. Moreover, liver involvement may be limited to subtle changes in organ texture especially in early childhood and some syndromic conditions, such as ciliopathies. Attenuation imaging coefficient (ATI), shear wave elas...

Descripción completa

Detalles Bibliográficos
Autores principales: Cetiner, Metin, Schiepek, Felix, Finkelberg, Ilja, Hirtz, Raphael, Büscher, Anja K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10150017/
https://www.ncbi.nlm.nih.gov/pubmed/37138563
http://dx.doi.org/10.3389/fped.2023.1020690
_version_ 1785035273897246720
author Cetiner, Metin
Schiepek, Felix
Finkelberg, Ilja
Hirtz, Raphael
Büscher, Anja K.
author_facet Cetiner, Metin
Schiepek, Felix
Finkelberg, Ilja
Hirtz, Raphael
Büscher, Anja K.
author_sort Cetiner, Metin
collection PubMed
description INTRODUCTION: The number of children with acute and chronic liver disease is rising. Moreover, liver involvement may be limited to subtle changes in organ texture especially in early childhood and some syndromic conditions, such as ciliopathies. Attenuation imaging coefficient (ATI), shear wave elastography (SWE), and dispersion (SWD) are emerging ultrasound technologies providing data about attenuation, elasticity, and viscosity of liver tissue. This additional and qualitative information has been correlated with certain liver pathologies. However, limited data are available for healthy controls and have mainly been raised in adults. METHODS: This prospective monocentric study was conducted at a university hospital with a specialization in pediatric liver disease and transplantation. Between February and July 2021, 129 children aged 0-17.92 years were recruited. Study participants attended outpatient clinics due to minor illnesses excluding liver or cardiac diseases, acute (febrile) infections or other conditions affecting liver tissue and function. ATI, SWE, and SWD measurements were performed on an Aplio i800 (Canon Medical Systems) with an i8CX1 curved transducer by two different investigators with long-standing experience in pediatric ultrasound according to a standardized protocol. RESULTS: Considering multiple potential covariates, we derived percentile charts for all 3 devices relying on the Lambda-Mu-Sigma (LMS) approach. 112 children were considered for further analysis, excluding those with abnormal liver function and under-/overweight (BMI SDS<-1.96/> 1.96, respectively). Age range was 0-17.92 years (mean 6.89±0.50SD), 58% were male. The mean duration of the ultrasound examination (basic ultrasound plus SWE, SWD, and ATI) was 6.67±0.22 minutes and it was well tolerated in 83% (n=92) of cases. While ATI was related to age, SWD was found to depend on BMI SDS, and SWE on abdominal wall thickness and sex. ATI correlated with neither SWE nor SWD, but SWE was correlated with SWD. CONCLUSIONS: Our study provides norm values and reference charts for ATI, SWE, and SWD considering important covariates including age, sex and, BMI. This may help to implement these promising tools into imaging diagnostics of liver disease and to improve the diagnostic relevance of liver ultrasound. In addition, these noninvasive techniques proved to be time-effective and highly reliable, which make them ideal for application in children.
format Online
Article
Text
id pubmed-10150017
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-101500172023-05-02 Validation of attenuation imaging coefficient, shear wave elastography, and dispersion as emerging tools for non-invasive evaluation of liver tissue in children Cetiner, Metin Schiepek, Felix Finkelberg, Ilja Hirtz, Raphael Büscher, Anja K. Front Pediatr Pediatrics INTRODUCTION: The number of children with acute and chronic liver disease is rising. Moreover, liver involvement may be limited to subtle changes in organ texture especially in early childhood and some syndromic conditions, such as ciliopathies. Attenuation imaging coefficient (ATI), shear wave elastography (SWE), and dispersion (SWD) are emerging ultrasound technologies providing data about attenuation, elasticity, and viscosity of liver tissue. This additional and qualitative information has been correlated with certain liver pathologies. However, limited data are available for healthy controls and have mainly been raised in adults. METHODS: This prospective monocentric study was conducted at a university hospital with a specialization in pediatric liver disease and transplantation. Between February and July 2021, 129 children aged 0-17.92 years were recruited. Study participants attended outpatient clinics due to minor illnesses excluding liver or cardiac diseases, acute (febrile) infections or other conditions affecting liver tissue and function. ATI, SWE, and SWD measurements were performed on an Aplio i800 (Canon Medical Systems) with an i8CX1 curved transducer by two different investigators with long-standing experience in pediatric ultrasound according to a standardized protocol. RESULTS: Considering multiple potential covariates, we derived percentile charts for all 3 devices relying on the Lambda-Mu-Sigma (LMS) approach. 112 children were considered for further analysis, excluding those with abnormal liver function and under-/overweight (BMI SDS<-1.96/> 1.96, respectively). Age range was 0-17.92 years (mean 6.89±0.50SD), 58% were male. The mean duration of the ultrasound examination (basic ultrasound plus SWE, SWD, and ATI) was 6.67±0.22 minutes and it was well tolerated in 83% (n=92) of cases. While ATI was related to age, SWD was found to depend on BMI SDS, and SWE on abdominal wall thickness and sex. ATI correlated with neither SWE nor SWD, but SWE was correlated with SWD. CONCLUSIONS: Our study provides norm values and reference charts for ATI, SWE, and SWD considering important covariates including age, sex and, BMI. This may help to implement these promising tools into imaging diagnostics of liver disease and to improve the diagnostic relevance of liver ultrasound. In addition, these noninvasive techniques proved to be time-effective and highly reliable, which make them ideal for application in children. Frontiers Media S.A. 2023-04-17 /pmc/articles/PMC10150017/ /pubmed/37138563 http://dx.doi.org/10.3389/fped.2023.1020690 Text en © 2023 Cetiner, Schiepek, Finkelberg, Hirtz and Büscher. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY) (https://creativecommons.org/licenses/by/4.0/) . The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Pediatrics
Cetiner, Metin
Schiepek, Felix
Finkelberg, Ilja
Hirtz, Raphael
Büscher, Anja K.
Validation of attenuation imaging coefficient, shear wave elastography, and dispersion as emerging tools for non-invasive evaluation of liver tissue in children
title Validation of attenuation imaging coefficient, shear wave elastography, and dispersion as emerging tools for non-invasive evaluation of liver tissue in children
title_full Validation of attenuation imaging coefficient, shear wave elastography, and dispersion as emerging tools for non-invasive evaluation of liver tissue in children
title_fullStr Validation of attenuation imaging coefficient, shear wave elastography, and dispersion as emerging tools for non-invasive evaluation of liver tissue in children
title_full_unstemmed Validation of attenuation imaging coefficient, shear wave elastography, and dispersion as emerging tools for non-invasive evaluation of liver tissue in children
title_short Validation of attenuation imaging coefficient, shear wave elastography, and dispersion as emerging tools for non-invasive evaluation of liver tissue in children
title_sort validation of attenuation imaging coefficient, shear wave elastography, and dispersion as emerging tools for non-invasive evaluation of liver tissue in children
topic Pediatrics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10150017/
https://www.ncbi.nlm.nih.gov/pubmed/37138563
http://dx.doi.org/10.3389/fped.2023.1020690
work_keys_str_mv AT cetinermetin validationofattenuationimagingcoefficientshearwaveelastographyanddispersionasemergingtoolsfornoninvasiveevaluationoflivertissueinchildren
AT schiepekfelix validationofattenuationimagingcoefficientshearwaveelastographyanddispersionasemergingtoolsfornoninvasiveevaluationoflivertissueinchildren
AT finkelbergilja validationofattenuationimagingcoefficientshearwaveelastographyanddispersionasemergingtoolsfornoninvasiveevaluationoflivertissueinchildren
AT hirtzraphael validationofattenuationimagingcoefficientshearwaveelastographyanddispersionasemergingtoolsfornoninvasiveevaluationoflivertissueinchildren
AT buscheranjak validationofattenuationimagingcoefficientshearwaveelastographyanddispersionasemergingtoolsfornoninvasiveevaluationoflivertissueinchildren