Accuracy of non-invasive cuffless blood pressure in the intensive care unit: Promises and challenges
OBJECTIVE: Continuous non-invasive cuffless blood pressure (BP) monitoring may reduce adverse outcomes in hospitalized patients if accuracy is approved. We aimed to investigate accuracy of two different BP prediction models in critically ill intensive care unit (ICU) patients, using a prototype cuff...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10150697/ https://www.ncbi.nlm.nih.gov/pubmed/37138759 http://dx.doi.org/10.3389/fmed.2023.1154041 |
_version_ | 1785035402821763072 |
---|---|
author | Heimark, Sondre Bøtker-Rasmussen, Kasper Gade Stepanov, Alexey Haga, Øyvind Gløersen Gonzalez, Victor Seeberg, Trine M. Fadl Elmula, Fadl Elmula M. Waldum-Grevbo, Bård |
author_facet | Heimark, Sondre Bøtker-Rasmussen, Kasper Gade Stepanov, Alexey Haga, Øyvind Gløersen Gonzalez, Victor Seeberg, Trine M. Fadl Elmula, Fadl Elmula M. Waldum-Grevbo, Bård |
author_sort | Heimark, Sondre |
collection | PubMed |
description | OBJECTIVE: Continuous non-invasive cuffless blood pressure (BP) monitoring may reduce adverse outcomes in hospitalized patients if accuracy is approved. We aimed to investigate accuracy of two different BP prediction models in critically ill intensive care unit (ICU) patients, using a prototype cuffless BP device based on electrocardiogram and photoplethysmography signals. We compared a pulse arrival time (PAT)-based BP model (generalized PAT-based model) derived from a general population cohort to more complex and individualized models (complex individualized models) utilizing other features of the BP sensor signals. METHODS: Patients admitted to an ICU with indication of invasive BP monitoring were included. The first half of each patient’s data was used to train a subject-specific machine learning model (complex individualized models). The second half was used to estimate BP and test accuracy of both the generalized PAT-based model and the complex individualized models. A total of 7,327 measurements of 15 s epochs were included in pairwise comparisons across 25 patients. RESULTS: The generalized PAT-based model achieved a mean absolute error (SD of errors) of 7.6 (7.2) mmHg, 3.3 (3.1) mmHg and 4.6 (4.4) mmHg for systolic BP, diastolic BP and mean arterial pressure (MAP) respectively. Corresponding results for the complex individualized model were 6.5 (6.7) mmHg, 3.1 (3.0) mmHg and 4.0 (4.0) mmHg. Percentage of absolute errors within 10 mmHg for the generalized model were 77.6, 96.2, and 89.6% for systolic BP, diastolic BP and MAP, respectively. Corresponding results for the individualized model were 83.8, 96.2, and 94.2%. Accuracy was significantly improved when comparing the complex individualized models to the generalized PAT-based model in systolic BP and MAP, but not diastolic BP. CONCLUSION: A generalized PAT-based model, developed from a different population was not able to accurately track BP changes in critically ill ICU patients. Individually fitted models utilizing other cuffless BP sensor signals significantly improved accuracy, indicating that cuffless BP can be measured non-invasively, but the challenge toward generalizable models remains for future research to resolve. |
format | Online Article Text |
id | pubmed-10150697 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-101506972023-05-02 Accuracy of non-invasive cuffless blood pressure in the intensive care unit: Promises and challenges Heimark, Sondre Bøtker-Rasmussen, Kasper Gade Stepanov, Alexey Haga, Øyvind Gløersen Gonzalez, Victor Seeberg, Trine M. Fadl Elmula, Fadl Elmula M. Waldum-Grevbo, Bård Front Med (Lausanne) Medicine OBJECTIVE: Continuous non-invasive cuffless blood pressure (BP) monitoring may reduce adverse outcomes in hospitalized patients if accuracy is approved. We aimed to investigate accuracy of two different BP prediction models in critically ill intensive care unit (ICU) patients, using a prototype cuffless BP device based on electrocardiogram and photoplethysmography signals. We compared a pulse arrival time (PAT)-based BP model (generalized PAT-based model) derived from a general population cohort to more complex and individualized models (complex individualized models) utilizing other features of the BP sensor signals. METHODS: Patients admitted to an ICU with indication of invasive BP monitoring were included. The first half of each patient’s data was used to train a subject-specific machine learning model (complex individualized models). The second half was used to estimate BP and test accuracy of both the generalized PAT-based model and the complex individualized models. A total of 7,327 measurements of 15 s epochs were included in pairwise comparisons across 25 patients. RESULTS: The generalized PAT-based model achieved a mean absolute error (SD of errors) of 7.6 (7.2) mmHg, 3.3 (3.1) mmHg and 4.6 (4.4) mmHg for systolic BP, diastolic BP and mean arterial pressure (MAP) respectively. Corresponding results for the complex individualized model were 6.5 (6.7) mmHg, 3.1 (3.0) mmHg and 4.0 (4.0) mmHg. Percentage of absolute errors within 10 mmHg for the generalized model were 77.6, 96.2, and 89.6% for systolic BP, diastolic BP and MAP, respectively. Corresponding results for the individualized model were 83.8, 96.2, and 94.2%. Accuracy was significantly improved when comparing the complex individualized models to the generalized PAT-based model in systolic BP and MAP, but not diastolic BP. CONCLUSION: A generalized PAT-based model, developed from a different population was not able to accurately track BP changes in critically ill ICU patients. Individually fitted models utilizing other cuffless BP sensor signals significantly improved accuracy, indicating that cuffless BP can be measured non-invasively, but the challenge toward generalizable models remains for future research to resolve. Frontiers Media S.A. 2023-04-17 /pmc/articles/PMC10150697/ /pubmed/37138759 http://dx.doi.org/10.3389/fmed.2023.1154041 Text en Copyright © 2023 Heimark, Bøtker-Rasmussen, Stepanov, Haga, Gonzalez, Seeberg, Fadl Elmula and Waldum-Grevbo. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Medicine Heimark, Sondre Bøtker-Rasmussen, Kasper Gade Stepanov, Alexey Haga, Øyvind Gløersen Gonzalez, Victor Seeberg, Trine M. Fadl Elmula, Fadl Elmula M. Waldum-Grevbo, Bård Accuracy of non-invasive cuffless blood pressure in the intensive care unit: Promises and challenges |
title | Accuracy of non-invasive cuffless blood pressure in the intensive care unit: Promises and challenges |
title_full | Accuracy of non-invasive cuffless blood pressure in the intensive care unit: Promises and challenges |
title_fullStr | Accuracy of non-invasive cuffless blood pressure in the intensive care unit: Promises and challenges |
title_full_unstemmed | Accuracy of non-invasive cuffless blood pressure in the intensive care unit: Promises and challenges |
title_short | Accuracy of non-invasive cuffless blood pressure in the intensive care unit: Promises and challenges |
title_sort | accuracy of non-invasive cuffless blood pressure in the intensive care unit: promises and challenges |
topic | Medicine |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10150697/ https://www.ncbi.nlm.nih.gov/pubmed/37138759 http://dx.doi.org/10.3389/fmed.2023.1154041 |
work_keys_str_mv | AT heimarksondre accuracyofnoninvasivecufflessbloodpressureintheintensivecareunitpromisesandchallenges AT bøtkerrasmussenkaspergade accuracyofnoninvasivecufflessbloodpressureintheintensivecareunitpromisesandchallenges AT stepanovalexey accuracyofnoninvasivecufflessbloodpressureintheintensivecareunitpromisesandchallenges AT hagaøyvindgløersen accuracyofnoninvasivecufflessbloodpressureintheintensivecareunitpromisesandchallenges AT gonzalezvictor accuracyofnoninvasivecufflessbloodpressureintheintensivecareunitpromisesandchallenges AT seebergtrinem accuracyofnoninvasivecufflessbloodpressureintheintensivecareunitpromisesandchallenges AT fadlelmulafadlelmulam accuracyofnoninvasivecufflessbloodpressureintheintensivecareunitpromisesandchallenges AT waldumgrevbobard accuracyofnoninvasivecufflessbloodpressureintheintensivecareunitpromisesandchallenges |