Changes in femoral rollback and rotation with increasing coupling in knee arthroplasty—a biomechanical in-vitro study

BACKGROUND: After total knee arthroplasty, 10–30% of patients still complain about knee pain, even after exact positioning of the components. Altered knee kinematics are crucial in this regard. The aim of our study was to experimentally determine the influence of different degrees of component coupl...

Descripción completa

Detalles Bibliográficos
Autores principales: Lorenz, Andrea, Winter, Alexander, Mederake, Moritz, Freidhager, Clemens, Hofmann, Ulf Krister, Leichtle, Ulf Gunther
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10152755/
https://www.ncbi.nlm.nih.gov/pubmed/37131176
http://dx.doi.org/10.1186/s12891-023-06430-w
_version_ 1785035802802126848
author Lorenz, Andrea
Winter, Alexander
Mederake, Moritz
Freidhager, Clemens
Hofmann, Ulf Krister
Leichtle, Ulf Gunther
author_facet Lorenz, Andrea
Winter, Alexander
Mederake, Moritz
Freidhager, Clemens
Hofmann, Ulf Krister
Leichtle, Ulf Gunther
author_sort Lorenz, Andrea
collection PubMed
description BACKGROUND: After total knee arthroplasty, 10–30% of patients still complain about knee pain, even after exact positioning of the components. Altered knee kinematics are crucial in this regard. The aim of our study was to experimentally determine the influence of different degrees of component coupling of knee prostheses on joint kinematics during muscle-loaded knee flexion in-vitro. METHODS: Femoral rollback and femoral rotation of a standard cruciate retaining (GCR), a posterior stabilized (GPS), a rotational hinge (RSL) and a total hinge (SSL) design of the same series of knee replacement implants (SL-series) of one single manufacturer (Waldemar Link GmbH, Hamburg, Germany) were analyzed and set in relation to the motion of the corresponding native knee in a paired study design. All different coupling degrees were analyzed in the same human knees. To simulate muscle loaded knee flexion, a knee simulator was used. Kinematics were measured with an ultrasonic motion capture system and integrated in a calculated coordinate system via CT-imaging. RESULTS: The largest posterior motion on the lateral side was found for the native knee (8.7 ± 7.0 mm), followed by the GPS (3.2 ± 5.1 mm) and GCR (2.8 ± 7.3 mm) implants, while no motion was found for the RSL (0.1 ± 3.0 mm) and the SSL (-0.6 ± 2.7 mm) implants. In contrast, on the medial side, only the native knee showed a posterior motion (2.1 ± 3.2 mm). Regarding femoral external rotation, the only implant where the observed difference did not reach statistical significance when compared to the native knee was the GCR (p = 0.007). CONCLUSION: The GCR and GPS kinematics closely imitate those of the native joint. Medial femoral rollback is reduced, however, with the joint pivoting around a rotational center located in the medial plateau. Without additional rotational forces, the coupled RSL and SSL prostheses closely resemble each other with no femoral rollback or relevant rotational component. The femoral axis, however, shifts ventrally in both models when compared with their primary counterparts. The positioning of the coupling mechanism in the femoral and tibial component thus can already lead to altered joint kinematics even in prostheses with an identical surface geometry.
format Online
Article
Text
id pubmed-10152755
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-101527552023-05-03 Changes in femoral rollback and rotation with increasing coupling in knee arthroplasty—a biomechanical in-vitro study Lorenz, Andrea Winter, Alexander Mederake, Moritz Freidhager, Clemens Hofmann, Ulf Krister Leichtle, Ulf Gunther BMC Musculoskelet Disord Research BACKGROUND: After total knee arthroplasty, 10–30% of patients still complain about knee pain, even after exact positioning of the components. Altered knee kinematics are crucial in this regard. The aim of our study was to experimentally determine the influence of different degrees of component coupling of knee prostheses on joint kinematics during muscle-loaded knee flexion in-vitro. METHODS: Femoral rollback and femoral rotation of a standard cruciate retaining (GCR), a posterior stabilized (GPS), a rotational hinge (RSL) and a total hinge (SSL) design of the same series of knee replacement implants (SL-series) of one single manufacturer (Waldemar Link GmbH, Hamburg, Germany) were analyzed and set in relation to the motion of the corresponding native knee in a paired study design. All different coupling degrees were analyzed in the same human knees. To simulate muscle loaded knee flexion, a knee simulator was used. Kinematics were measured with an ultrasonic motion capture system and integrated in a calculated coordinate system via CT-imaging. RESULTS: The largest posterior motion on the lateral side was found for the native knee (8.7 ± 7.0 mm), followed by the GPS (3.2 ± 5.1 mm) and GCR (2.8 ± 7.3 mm) implants, while no motion was found for the RSL (0.1 ± 3.0 mm) and the SSL (-0.6 ± 2.7 mm) implants. In contrast, on the medial side, only the native knee showed a posterior motion (2.1 ± 3.2 mm). Regarding femoral external rotation, the only implant where the observed difference did not reach statistical significance when compared to the native knee was the GCR (p = 0.007). CONCLUSION: The GCR and GPS kinematics closely imitate those of the native joint. Medial femoral rollback is reduced, however, with the joint pivoting around a rotational center located in the medial plateau. Without additional rotational forces, the coupled RSL and SSL prostheses closely resemble each other with no femoral rollback or relevant rotational component. The femoral axis, however, shifts ventrally in both models when compared with their primary counterparts. The positioning of the coupling mechanism in the femoral and tibial component thus can already lead to altered joint kinematics even in prostheses with an identical surface geometry. BioMed Central 2023-05-02 /pmc/articles/PMC10152755/ /pubmed/37131176 http://dx.doi.org/10.1186/s12891-023-06430-w Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Lorenz, Andrea
Winter, Alexander
Mederake, Moritz
Freidhager, Clemens
Hofmann, Ulf Krister
Leichtle, Ulf Gunther
Changes in femoral rollback and rotation with increasing coupling in knee arthroplasty—a biomechanical in-vitro study
title Changes in femoral rollback and rotation with increasing coupling in knee arthroplasty—a biomechanical in-vitro study
title_full Changes in femoral rollback and rotation with increasing coupling in knee arthroplasty—a biomechanical in-vitro study
title_fullStr Changes in femoral rollback and rotation with increasing coupling in knee arthroplasty—a biomechanical in-vitro study
title_full_unstemmed Changes in femoral rollback and rotation with increasing coupling in knee arthroplasty—a biomechanical in-vitro study
title_short Changes in femoral rollback and rotation with increasing coupling in knee arthroplasty—a biomechanical in-vitro study
title_sort changes in femoral rollback and rotation with increasing coupling in knee arthroplasty—a biomechanical in-vitro study
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10152755/
https://www.ncbi.nlm.nih.gov/pubmed/37131176
http://dx.doi.org/10.1186/s12891-023-06430-w
work_keys_str_mv AT lorenzandrea changesinfemoralrollbackandrotationwithincreasingcouplinginkneearthroplastyabiomechanicalinvitrostudy
AT winteralexander changesinfemoralrollbackandrotationwithincreasingcouplinginkneearthroplastyabiomechanicalinvitrostudy
AT mederakemoritz changesinfemoralrollbackandrotationwithincreasingcouplinginkneearthroplastyabiomechanicalinvitrostudy
AT freidhagerclemens changesinfemoralrollbackandrotationwithincreasingcouplinginkneearthroplastyabiomechanicalinvitrostudy
AT hofmannulfkrister changesinfemoralrollbackandrotationwithincreasingcouplinginkneearthroplastyabiomechanicalinvitrostudy
AT leichtleulfgunther changesinfemoralrollbackandrotationwithincreasingcouplinginkneearthroplastyabiomechanicalinvitrostudy