The design and validation of a low-cost trans perineal (TP) prostate biopsy simulator for training: improving trainees’ confidence and cognitive targeting skills
PURPOSE: The aim of this research was to create a novel and low-cost TP prostate biopsy simulator that has face, content and construct validity with high educational value. METHODS: This research developed a trans perineal prostate (TP) biopsy simulator using 3D-printed moulds and tissue-mimicking m...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10153043/ https://www.ncbi.nlm.nih.gov/pubmed/37129680 http://dx.doi.org/10.1007/s00345-023-04387-y |
_version_ | 1785035861231927296 |
---|---|
author | Ong, Kelly Bald, Philip Dryhurst, David Ahmed, Saif Yusuf, Gibran Tim Lunawat, Rahul Sriprasad, Seshadri Thapa, Gauri Tirnoveanu, Alice Webb, Richard Rahman, Eqram |
author_facet | Ong, Kelly Bald, Philip Dryhurst, David Ahmed, Saif Yusuf, Gibran Tim Lunawat, Rahul Sriprasad, Seshadri Thapa, Gauri Tirnoveanu, Alice Webb, Richard Rahman, Eqram |
author_sort | Ong, Kelly |
collection | PubMed |
description | PURPOSE: The aim of this research was to create a novel and low-cost TP prostate biopsy simulator that has face, content and construct validity with high educational value. METHODS: This research developed a trans perineal prostate (TP) biopsy simulator using 3D-printed moulds and tissue-mimicking materials. Important regions (anterior, mid, and posterior zones) were coded with different colours. Ultrasound visible abnormal lesions were embedded in the prostate phantom. Expert and novice participants in TP biopsies were recruited. Essential skills were identified through the consensus of six experts. These skills were assessed through tasks performed by participants. This included the accuracy and timing of systematic and target biopsies. Immediate feedback was determined by the colour of the biopsy cores taken. A survey was distributed to evaluate its realism and educational value. RESULTS: The material cost of one simulator was £7.50. This simulator was proven to have face, content, and construct validity. There was a significant difference (p = 0.02) in the accuracy of systematic biopsies between both experts and novices. Significant difference was also observed (p = 0.01), in accurately identifying target lesion on ultrasound between both groups. Participants rated the overall realism of the simulator 4.57/5 (range 3–5). 100% of the experts agreed that introducing this simulator to training will be beneficial. 85.7% of the participants strongly agree that the simulator improved their confidence in TP biopsies. CONCLUSION: There is value in integrating this proof-of-concept TP prostate biopsy simulator into training. It has highly rated educational value and has face, content, and construct validity. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00345-023-04387-y. |
format | Online Article Text |
id | pubmed-10153043 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Springer Berlin Heidelberg |
record_format | MEDLINE/PubMed |
spelling | pubmed-101530432023-05-03 The design and validation of a low-cost trans perineal (TP) prostate biopsy simulator for training: improving trainees’ confidence and cognitive targeting skills Ong, Kelly Bald, Philip Dryhurst, David Ahmed, Saif Yusuf, Gibran Tim Lunawat, Rahul Sriprasad, Seshadri Thapa, Gauri Tirnoveanu, Alice Webb, Richard Rahman, Eqram World J Urol Original Article PURPOSE: The aim of this research was to create a novel and low-cost TP prostate biopsy simulator that has face, content and construct validity with high educational value. METHODS: This research developed a trans perineal prostate (TP) biopsy simulator using 3D-printed moulds and tissue-mimicking materials. Important regions (anterior, mid, and posterior zones) were coded with different colours. Ultrasound visible abnormal lesions were embedded in the prostate phantom. Expert and novice participants in TP biopsies were recruited. Essential skills were identified through the consensus of six experts. These skills were assessed through tasks performed by participants. This included the accuracy and timing of systematic and target biopsies. Immediate feedback was determined by the colour of the biopsy cores taken. A survey was distributed to evaluate its realism and educational value. RESULTS: The material cost of one simulator was £7.50. This simulator was proven to have face, content, and construct validity. There was a significant difference (p = 0.02) in the accuracy of systematic biopsies between both experts and novices. Significant difference was also observed (p = 0.01), in accurately identifying target lesion on ultrasound between both groups. Participants rated the overall realism of the simulator 4.57/5 (range 3–5). 100% of the experts agreed that introducing this simulator to training will be beneficial. 85.7% of the participants strongly agree that the simulator improved their confidence in TP biopsies. CONCLUSION: There is value in integrating this proof-of-concept TP prostate biopsy simulator into training. It has highly rated educational value and has face, content, and construct validity. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00345-023-04387-y. Springer Berlin Heidelberg 2023-05-02 2023 /pmc/articles/PMC10153043/ /pubmed/37129680 http://dx.doi.org/10.1007/s00345-023-04387-y Text en © The Author(s), under exclusive licence to Springer-Verlag GmbH Germany, part of Springer Nature 2023. Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law. This article is made available via the PMC Open Access Subset for unrestricted research re-use and secondary analysis in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic. |
spellingShingle | Original Article Ong, Kelly Bald, Philip Dryhurst, David Ahmed, Saif Yusuf, Gibran Tim Lunawat, Rahul Sriprasad, Seshadri Thapa, Gauri Tirnoveanu, Alice Webb, Richard Rahman, Eqram The design and validation of a low-cost trans perineal (TP) prostate biopsy simulator for training: improving trainees’ confidence and cognitive targeting skills |
title | The design and validation of a low-cost trans perineal (TP) prostate biopsy simulator for training: improving trainees’ confidence and cognitive targeting skills |
title_full | The design and validation of a low-cost trans perineal (TP) prostate biopsy simulator for training: improving trainees’ confidence and cognitive targeting skills |
title_fullStr | The design and validation of a low-cost trans perineal (TP) prostate biopsy simulator for training: improving trainees’ confidence and cognitive targeting skills |
title_full_unstemmed | The design and validation of a low-cost trans perineal (TP) prostate biopsy simulator for training: improving trainees’ confidence and cognitive targeting skills |
title_short | The design and validation of a low-cost trans perineal (TP) prostate biopsy simulator for training: improving trainees’ confidence and cognitive targeting skills |
title_sort | design and validation of a low-cost trans perineal (tp) prostate biopsy simulator for training: improving trainees’ confidence and cognitive targeting skills |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10153043/ https://www.ncbi.nlm.nih.gov/pubmed/37129680 http://dx.doi.org/10.1007/s00345-023-04387-y |
work_keys_str_mv | AT ongkelly thedesignandvalidationofalowcosttransperinealtpprostatebiopsysimulatorfortrainingimprovingtraineesconfidenceandcognitivetargetingskills AT baldphilip thedesignandvalidationofalowcosttransperinealtpprostatebiopsysimulatorfortrainingimprovingtraineesconfidenceandcognitivetargetingskills AT dryhurstdavid thedesignandvalidationofalowcosttransperinealtpprostatebiopsysimulatorfortrainingimprovingtraineesconfidenceandcognitivetargetingskills AT ahmedsaif thedesignandvalidationofalowcosttransperinealtpprostatebiopsysimulatorfortrainingimprovingtraineesconfidenceandcognitivetargetingskills AT yusufgibrantim thedesignandvalidationofalowcosttransperinealtpprostatebiopsysimulatorfortrainingimprovingtraineesconfidenceandcognitivetargetingskills AT lunawatrahul thedesignandvalidationofalowcosttransperinealtpprostatebiopsysimulatorfortrainingimprovingtraineesconfidenceandcognitivetargetingskills AT sriprasadseshadri thedesignandvalidationofalowcosttransperinealtpprostatebiopsysimulatorfortrainingimprovingtraineesconfidenceandcognitivetargetingskills AT thapagauri thedesignandvalidationofalowcosttransperinealtpprostatebiopsysimulatorfortrainingimprovingtraineesconfidenceandcognitivetargetingskills AT tirnoveanualice thedesignandvalidationofalowcosttransperinealtpprostatebiopsysimulatorfortrainingimprovingtraineesconfidenceandcognitivetargetingskills AT webbrichard thedesignandvalidationofalowcosttransperinealtpprostatebiopsysimulatorfortrainingimprovingtraineesconfidenceandcognitivetargetingskills AT rahmaneqram thedesignandvalidationofalowcosttransperinealtpprostatebiopsysimulatorfortrainingimprovingtraineesconfidenceandcognitivetargetingskills AT ongkelly designandvalidationofalowcosttransperinealtpprostatebiopsysimulatorfortrainingimprovingtraineesconfidenceandcognitivetargetingskills AT baldphilip designandvalidationofalowcosttransperinealtpprostatebiopsysimulatorfortrainingimprovingtraineesconfidenceandcognitivetargetingskills AT dryhurstdavid designandvalidationofalowcosttransperinealtpprostatebiopsysimulatorfortrainingimprovingtraineesconfidenceandcognitivetargetingskills AT ahmedsaif designandvalidationofalowcosttransperinealtpprostatebiopsysimulatorfortrainingimprovingtraineesconfidenceandcognitivetargetingskills AT yusufgibrantim designandvalidationofalowcosttransperinealtpprostatebiopsysimulatorfortrainingimprovingtraineesconfidenceandcognitivetargetingskills AT lunawatrahul designandvalidationofalowcosttransperinealtpprostatebiopsysimulatorfortrainingimprovingtraineesconfidenceandcognitivetargetingskills AT sriprasadseshadri designandvalidationofalowcosttransperinealtpprostatebiopsysimulatorfortrainingimprovingtraineesconfidenceandcognitivetargetingskills AT thapagauri designandvalidationofalowcosttransperinealtpprostatebiopsysimulatorfortrainingimprovingtraineesconfidenceandcognitivetargetingskills AT tirnoveanualice designandvalidationofalowcosttransperinealtpprostatebiopsysimulatorfortrainingimprovingtraineesconfidenceandcognitivetargetingskills AT webbrichard designandvalidationofalowcosttransperinealtpprostatebiopsysimulatorfortrainingimprovingtraineesconfidenceandcognitivetargetingskills AT rahmaneqram designandvalidationofalowcosttransperinealtpprostatebiopsysimulatorfortrainingimprovingtraineesconfidenceandcognitivetargetingskills |