Cargando…

A systematic review of the applications of markerless motion capture (MMC) technology for clinical measurement in rehabilitation

BACKGROUND: Markerless motion capture (MMC) technology has been developed to avoid the need for body marker placement during motion tracking and analysis of human movement. Although researchers have long proposed the use of MMC technology in clinical measurement—identification and measurement of mov...

Descripción completa

Detalles Bibliográficos
Autores principales: Lam, Winnie W. T., Tang, Yuk Ming, Fong, Kenneth N. K.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10155325/
https://www.ncbi.nlm.nih.gov/pubmed/37131238
http://dx.doi.org/10.1186/s12984-023-01186-9
_version_ 1785036303833759744
author Lam, Winnie W. T.
Tang, Yuk Ming
Fong, Kenneth N. K.
author_facet Lam, Winnie W. T.
Tang, Yuk Ming
Fong, Kenneth N. K.
author_sort Lam, Winnie W. T.
collection PubMed
description BACKGROUND: Markerless motion capture (MMC) technology has been developed to avoid the need for body marker placement during motion tracking and analysis of human movement. Although researchers have long proposed the use of MMC technology in clinical measurement—identification and measurement of movement kinematics in a clinical population, its actual application is still in its preliminary stages. The benefits of MMC technology are also inconclusive with regard to its use in assessing patients’ conditions. In this review we put a minor focus on the method’s engineering components and sought primarily to determine the current application of MMC as a clinical measurement tool in rehabilitation. METHODS: A systematic computerized literature search was conducted in PubMed, Medline, CINAHL, CENTRAL, EMBASE, and IEEE. The search keywords used in each database were “Markerless Motion Capture OR Motion Capture OR Motion Capture Technology OR Markerless Motion Capture Technology OR Computer Vision OR Video-based OR Pose Estimation AND Assessment OR Clinical Assessment OR Clinical Measurement OR Assess.” Only peer-reviewed articles that applied MMC technology for clinical measurement were included. The last search took place on March 6, 2023. Details regarding the application of MMC technology for different types of patients and body parts, as well as the assessment results, were summarized. RESULTS: A total of 65 studies were included. The MMC systems used for measurement were most frequently used to identify symptoms or to detect differences in movement patterns between disease populations and their healthy counterparts. Patients with Parkinson’s disease (PD) who demonstrated obvious and well-defined physical signs were the largest patient group to which MMC assessment had been applied. Microsoft Kinect was the most frequently used MMC system, although there was a recent trend of motion analysis using video captured with a smartphone camera. CONCLUSIONS: This review explored the current uses of MMC technology for clinical measurement. MMC technology has the potential to be used as an assessment tool as well as to assist in the detection and identification of symptoms, which might further contribute to the use of an artificial intelligence method for early screening for diseases. Further studies are warranted to develop and integrate MMC system in a platform that can be user-friendly and accurately analyzed by clinicians to extend the use of MMC technology in the disease populations.
format Online
Article
Text
id pubmed-10155325
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-101553252023-05-04 A systematic review of the applications of markerless motion capture (MMC) technology for clinical measurement in rehabilitation Lam, Winnie W. T. Tang, Yuk Ming Fong, Kenneth N. K. J Neuroeng Rehabil Review BACKGROUND: Markerless motion capture (MMC) technology has been developed to avoid the need for body marker placement during motion tracking and analysis of human movement. Although researchers have long proposed the use of MMC technology in clinical measurement—identification and measurement of movement kinematics in a clinical population, its actual application is still in its preliminary stages. The benefits of MMC technology are also inconclusive with regard to its use in assessing patients’ conditions. In this review we put a minor focus on the method’s engineering components and sought primarily to determine the current application of MMC as a clinical measurement tool in rehabilitation. METHODS: A systematic computerized literature search was conducted in PubMed, Medline, CINAHL, CENTRAL, EMBASE, and IEEE. The search keywords used in each database were “Markerless Motion Capture OR Motion Capture OR Motion Capture Technology OR Markerless Motion Capture Technology OR Computer Vision OR Video-based OR Pose Estimation AND Assessment OR Clinical Assessment OR Clinical Measurement OR Assess.” Only peer-reviewed articles that applied MMC technology for clinical measurement were included. The last search took place on March 6, 2023. Details regarding the application of MMC technology for different types of patients and body parts, as well as the assessment results, were summarized. RESULTS: A total of 65 studies were included. The MMC systems used for measurement were most frequently used to identify symptoms or to detect differences in movement patterns between disease populations and their healthy counterparts. Patients with Parkinson’s disease (PD) who demonstrated obvious and well-defined physical signs were the largest patient group to which MMC assessment had been applied. Microsoft Kinect was the most frequently used MMC system, although there was a recent trend of motion analysis using video captured with a smartphone camera. CONCLUSIONS: This review explored the current uses of MMC technology for clinical measurement. MMC technology has the potential to be used as an assessment tool as well as to assist in the detection and identification of symptoms, which might further contribute to the use of an artificial intelligence method for early screening for diseases. Further studies are warranted to develop and integrate MMC system in a platform that can be user-friendly and accurately analyzed by clinicians to extend the use of MMC technology in the disease populations. BioMed Central 2023-05-02 /pmc/articles/PMC10155325/ /pubmed/37131238 http://dx.doi.org/10.1186/s12984-023-01186-9 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Review
Lam, Winnie W. T.
Tang, Yuk Ming
Fong, Kenneth N. K.
A systematic review of the applications of markerless motion capture (MMC) technology for clinical measurement in rehabilitation
title A systematic review of the applications of markerless motion capture (MMC) technology for clinical measurement in rehabilitation
title_full A systematic review of the applications of markerless motion capture (MMC) technology for clinical measurement in rehabilitation
title_fullStr A systematic review of the applications of markerless motion capture (MMC) technology for clinical measurement in rehabilitation
title_full_unstemmed A systematic review of the applications of markerless motion capture (MMC) technology for clinical measurement in rehabilitation
title_short A systematic review of the applications of markerless motion capture (MMC) technology for clinical measurement in rehabilitation
title_sort systematic review of the applications of markerless motion capture (mmc) technology for clinical measurement in rehabilitation
topic Review
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10155325/
https://www.ncbi.nlm.nih.gov/pubmed/37131238
http://dx.doi.org/10.1186/s12984-023-01186-9
work_keys_str_mv AT lamwinniewt asystematicreviewoftheapplicationsofmarkerlessmotioncapturemmctechnologyforclinicalmeasurementinrehabilitation
AT tangyukming asystematicreviewoftheapplicationsofmarkerlessmotioncapturemmctechnologyforclinicalmeasurementinrehabilitation
AT fongkennethnk asystematicreviewoftheapplicationsofmarkerlessmotioncapturemmctechnologyforclinicalmeasurementinrehabilitation
AT lamwinniewt systematicreviewoftheapplicationsofmarkerlessmotioncapturemmctechnologyforclinicalmeasurementinrehabilitation
AT tangyukming systematicreviewoftheapplicationsofmarkerlessmotioncapturemmctechnologyforclinicalmeasurementinrehabilitation
AT fongkennethnk systematicreviewoftheapplicationsofmarkerlessmotioncapturemmctechnologyforclinicalmeasurementinrehabilitation