Cargando…

Effectiveness of individualized 3D titanium-printed Orthognathic osteotomy guides and custom plates

BACKGROUND: Computer-aided design/manufacturing (CAD/CAM) technology was developed to improve surgical accuracy and minimize errors in surgical planning and orthognathic surgery. However, its accurate implementation during surgery remains a challenge. Hence, we compared the accuracy and stability of...

Descripción completa

Detalles Bibliográficos
Autores principales: Kim, Se-hyang, Lee, Sung-Min, Park, Jung-Hyun, Yang, Sook, Kim, Jin-Woo
Formato: Online Artículo Texto
Lenguaje:English
Publicado: BioMed Central 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10155400/
https://www.ncbi.nlm.nih.gov/pubmed/37138237
http://dx.doi.org/10.1186/s12903-023-03000-3
_version_ 1785036320331005952
author Kim, Se-hyang
Lee, Sung-Min
Park, Jung-Hyun
Yang, Sook
Kim, Jin-Woo
author_facet Kim, Se-hyang
Lee, Sung-Min
Park, Jung-Hyun
Yang, Sook
Kim, Jin-Woo
author_sort Kim, Se-hyang
collection PubMed
description BACKGROUND: Computer-aided design/manufacturing (CAD/CAM) technology was developed to improve surgical accuracy and minimize errors in surgical planning and orthognathic surgery. However, its accurate implementation during surgery remains a challenge. Hence, we compared the accuracy and stability of conventional orthognathic surgery and the novel modalities, such as virtual simulation and three-dimensional (3D) titanium-printed customized surgical osteotomy guides and plates. METHODS: This prospective study included 12 patients who were willing to undergo orthognathic surgery. The study group consisted of patients who underwent orthognathic two-jaw surgery using 3D-printed patient-specific plates processed by selective laser melting and an osteotomy guide; orthognathic surgery was also performed by the surgeon directly bending the ready-made plate in the control group. Based on the preoperative computed tomography images and intraoral 3D scan data, a 3D virtual surgery plan was implemented in the virtual simulation module, and the surgical guide and bone fixation plate were fabricated. The accuracy and stability were evaluated by comparing the results of the preoperative virtual simulation (T0) to those at 7 days (T1) and 6 months (T2) post-surgery. RESULT: The accuracy (ΔT1‒T0) and stability (ΔT2‒T1) measurements, using 11 anatomical references, both demonstrated more accurate results in the study group. The mean difference of accuracy for the study group (0.485 ± 0.280 mm) was significantly lower than in the control group (1.213 ± 0.716 mm) (P < 0.01). The mean operation time (6.83 ± 0.72 h) in the control group was longer than in the study group (5.76 ± 0.43 h) (P < 0.05). CONCLUSION: This prospective clinical study demonstrated the accuracy, stability, and effectiveness of using virtual preoperative simulation and patient-customized osteotomy guides and plates for orthognathic surgery.
format Online
Article
Text
id pubmed-10155400
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher BioMed Central
record_format MEDLINE/PubMed
spelling pubmed-101554002023-05-04 Effectiveness of individualized 3D titanium-printed Orthognathic osteotomy guides and custom plates Kim, Se-hyang Lee, Sung-Min Park, Jung-Hyun Yang, Sook Kim, Jin-Woo BMC Oral Health Research BACKGROUND: Computer-aided design/manufacturing (CAD/CAM) technology was developed to improve surgical accuracy and minimize errors in surgical planning and orthognathic surgery. However, its accurate implementation during surgery remains a challenge. Hence, we compared the accuracy and stability of conventional orthognathic surgery and the novel modalities, such as virtual simulation and three-dimensional (3D) titanium-printed customized surgical osteotomy guides and plates. METHODS: This prospective study included 12 patients who were willing to undergo orthognathic surgery. The study group consisted of patients who underwent orthognathic two-jaw surgery using 3D-printed patient-specific plates processed by selective laser melting and an osteotomy guide; orthognathic surgery was also performed by the surgeon directly bending the ready-made plate in the control group. Based on the preoperative computed tomography images and intraoral 3D scan data, a 3D virtual surgery plan was implemented in the virtual simulation module, and the surgical guide and bone fixation plate were fabricated. The accuracy and stability were evaluated by comparing the results of the preoperative virtual simulation (T0) to those at 7 days (T1) and 6 months (T2) post-surgery. RESULT: The accuracy (ΔT1‒T0) and stability (ΔT2‒T1) measurements, using 11 anatomical references, both demonstrated more accurate results in the study group. The mean difference of accuracy for the study group (0.485 ± 0.280 mm) was significantly lower than in the control group (1.213 ± 0.716 mm) (P < 0.01). The mean operation time (6.83 ± 0.72 h) in the control group was longer than in the study group (5.76 ± 0.43 h) (P < 0.05). CONCLUSION: This prospective clinical study demonstrated the accuracy, stability, and effectiveness of using virtual preoperative simulation and patient-customized osteotomy guides and plates for orthognathic surgery. BioMed Central 2023-05-03 /pmc/articles/PMC10155400/ /pubmed/37138237 http://dx.doi.org/10.1186/s12903-023-03000-3 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data.
spellingShingle Research
Kim, Se-hyang
Lee, Sung-Min
Park, Jung-Hyun
Yang, Sook
Kim, Jin-Woo
Effectiveness of individualized 3D titanium-printed Orthognathic osteotomy guides and custom plates
title Effectiveness of individualized 3D titanium-printed Orthognathic osteotomy guides and custom plates
title_full Effectiveness of individualized 3D titanium-printed Orthognathic osteotomy guides and custom plates
title_fullStr Effectiveness of individualized 3D titanium-printed Orthognathic osteotomy guides and custom plates
title_full_unstemmed Effectiveness of individualized 3D titanium-printed Orthognathic osteotomy guides and custom plates
title_short Effectiveness of individualized 3D titanium-printed Orthognathic osteotomy guides and custom plates
title_sort effectiveness of individualized 3d titanium-printed orthognathic osteotomy guides and custom plates
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10155400/
https://www.ncbi.nlm.nih.gov/pubmed/37138237
http://dx.doi.org/10.1186/s12903-023-03000-3
work_keys_str_mv AT kimsehyang effectivenessofindividualized3dtitaniumprintedorthognathicosteotomyguidesandcustomplates
AT leesungmin effectivenessofindividualized3dtitaniumprintedorthognathicosteotomyguidesandcustomplates
AT parkjunghyun effectivenessofindividualized3dtitaniumprintedorthognathicosteotomyguidesandcustomplates
AT yangsook effectivenessofindividualized3dtitaniumprintedorthognathicosteotomyguidesandcustomplates
AT kimjinwoo effectivenessofindividualized3dtitaniumprintedorthognathicosteotomyguidesandcustomplates