Cargando…

Determination of Isoniazid Gained Fluorescent with 9-Anthraldehyde by HPLC-FL Method in Dosage Forms

PURPOSE: Tuberculosis is a chronic necrotizing bacterial infection caused by Mycobacterium tuberculosis, which has not lost its prevalence in the society from the past to the present. Isoniazid (INH) is an important drug used in the treatment of tuberculosis and is used for all forms of tuberculosis...

Descripción completa

Detalles Bibliográficos
Autores principales: Demirkaya Miloglu, Fatma, Bayrak, Burak, Kadioglu, Yucel
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer International Publishing 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10155667/
http://dx.doi.org/10.1007/s42250-023-00676-6
_version_ 1785036379892219904
author Demirkaya Miloglu, Fatma
Bayrak, Burak
Kadioglu, Yucel
author_facet Demirkaya Miloglu, Fatma
Bayrak, Burak
Kadioglu, Yucel
author_sort Demirkaya Miloglu, Fatma
collection PubMed
description PURPOSE: Tuberculosis is a chronic necrotizing bacterial infection caused by Mycobacterium tuberculosis, which has not lost its prevalence in the society from the past to the present. Isoniazid (INH) is an important drug used in the treatment of tuberculosis and is used for all forms of tuberculosis caused by Mycobacterium tuberculosis, unless there is resistance. This study is aimed to develop and validate a new HPLC with fluorescence detector (HPLC-FL) based on the formation of a coloured product (9-anthraldehyde isonicotinoyl hydrazone, INHAA) resulting from the condensation reaction of INH with 9-anthraldehyde(9-AA) for the determination of INH in dosage forms. METHODS: Optimum INHAA formation was obtained at 68 °C and 1.97 mL 0.05 M 9-AA for 3 h using a chemometric tool which is one of the green analytical chemistry strategies. INHAA was separated on a C18 reversed-phase column in conjunction with an isocratic elution of a mobile phase composed of methanol-Milli-Q grade water and detected by fluorescence detection (FL) at excitation (390 nm) and emission (489 nm) wavelengths. RESULTS: The method was linear over concentration range that varies between 0.5 and 20 µg/mL INH. The limit of detection (LOD) and limit of quantitation (LOQ) were estimated based on three and ten times the baseline noise and were found to be 0.11 µg/mL and 0.33 µg/mL INH, respectively. The optimized HPLC-FL parameters were applied to the analysis of drug dosage forms INH containing for quality control purposes. CONCLUSION: A new HPLC-FL method was developed for the analysis of INH in drug dosage forms, which saves time, effort and chemicals in the experimental design. GRAPHICAL ABSTRACT: [Image: see text]
format Online
Article
Text
id pubmed-10155667
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Springer International Publishing
record_format MEDLINE/PubMed
spelling pubmed-101556672023-05-09 Determination of Isoniazid Gained Fluorescent with 9-Anthraldehyde by HPLC-FL Method in Dosage Forms Demirkaya Miloglu, Fatma Bayrak, Burak Kadioglu, Yucel Chemistry Africa Original Article PURPOSE: Tuberculosis is a chronic necrotizing bacterial infection caused by Mycobacterium tuberculosis, which has not lost its prevalence in the society from the past to the present. Isoniazid (INH) is an important drug used in the treatment of tuberculosis and is used for all forms of tuberculosis caused by Mycobacterium tuberculosis, unless there is resistance. This study is aimed to develop and validate a new HPLC with fluorescence detector (HPLC-FL) based on the formation of a coloured product (9-anthraldehyde isonicotinoyl hydrazone, INHAA) resulting from the condensation reaction of INH with 9-anthraldehyde(9-AA) for the determination of INH in dosage forms. METHODS: Optimum INHAA formation was obtained at 68 °C and 1.97 mL 0.05 M 9-AA for 3 h using a chemometric tool which is one of the green analytical chemistry strategies. INHAA was separated on a C18 reversed-phase column in conjunction with an isocratic elution of a mobile phase composed of methanol-Milli-Q grade water and detected by fluorescence detection (FL) at excitation (390 nm) and emission (489 nm) wavelengths. RESULTS: The method was linear over concentration range that varies between 0.5 and 20 µg/mL INH. The limit of detection (LOD) and limit of quantitation (LOQ) were estimated based on three and ten times the baseline noise and were found to be 0.11 µg/mL and 0.33 µg/mL INH, respectively. The optimized HPLC-FL parameters were applied to the analysis of drug dosage forms INH containing for quality control purposes. CONCLUSION: A new HPLC-FL method was developed for the analysis of INH in drug dosage forms, which saves time, effort and chemicals in the experimental design. GRAPHICAL ABSTRACT: [Image: see text] Springer International Publishing 2023-05-03 /pmc/articles/PMC10155667/ http://dx.doi.org/10.1007/s42250-023-00676-6 Text en © The Tunisian Chemical Society and Springer Nature Switzerland AG 2023, Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law. This article is made available via the PMC Open Access Subset for unrestricted research re-use and secondary analysis in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic.
spellingShingle Original Article
Demirkaya Miloglu, Fatma
Bayrak, Burak
Kadioglu, Yucel
Determination of Isoniazid Gained Fluorescent with 9-Anthraldehyde by HPLC-FL Method in Dosage Forms
title Determination of Isoniazid Gained Fluorescent with 9-Anthraldehyde by HPLC-FL Method in Dosage Forms
title_full Determination of Isoniazid Gained Fluorescent with 9-Anthraldehyde by HPLC-FL Method in Dosage Forms
title_fullStr Determination of Isoniazid Gained Fluorescent with 9-Anthraldehyde by HPLC-FL Method in Dosage Forms
title_full_unstemmed Determination of Isoniazid Gained Fluorescent with 9-Anthraldehyde by HPLC-FL Method in Dosage Forms
title_short Determination of Isoniazid Gained Fluorescent with 9-Anthraldehyde by HPLC-FL Method in Dosage Forms
title_sort determination of isoniazid gained fluorescent with 9-anthraldehyde by hplc-fl method in dosage forms
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10155667/
http://dx.doi.org/10.1007/s42250-023-00676-6
work_keys_str_mv AT demirkayamiloglufatma determinationofisoniazidgainedfluorescentwith9anthraldehydebyhplcflmethodindosageforms
AT bayrakburak determinationofisoniazidgainedfluorescentwith9anthraldehydebyhplcflmethodindosageforms
AT kadiogluyucel determinationofisoniazidgainedfluorescentwith9anthraldehydebyhplcflmethodindosageforms