Cargando…
Determination of Isoniazid Gained Fluorescent with 9-Anthraldehyde by HPLC-FL Method in Dosage Forms
PURPOSE: Tuberculosis is a chronic necrotizing bacterial infection caused by Mycobacterium tuberculosis, which has not lost its prevalence in the society from the past to the present. Isoniazid (INH) is an important drug used in the treatment of tuberculosis and is used for all forms of tuberculosis...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer International Publishing
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10155667/ http://dx.doi.org/10.1007/s42250-023-00676-6 |
_version_ | 1785036379892219904 |
---|---|
author | Demirkaya Miloglu, Fatma Bayrak, Burak Kadioglu, Yucel |
author_facet | Demirkaya Miloglu, Fatma Bayrak, Burak Kadioglu, Yucel |
author_sort | Demirkaya Miloglu, Fatma |
collection | PubMed |
description | PURPOSE: Tuberculosis is a chronic necrotizing bacterial infection caused by Mycobacterium tuberculosis, which has not lost its prevalence in the society from the past to the present. Isoniazid (INH) is an important drug used in the treatment of tuberculosis and is used for all forms of tuberculosis caused by Mycobacterium tuberculosis, unless there is resistance. This study is aimed to develop and validate a new HPLC with fluorescence detector (HPLC-FL) based on the formation of a coloured product (9-anthraldehyde isonicotinoyl hydrazone, INHAA) resulting from the condensation reaction of INH with 9-anthraldehyde(9-AA) for the determination of INH in dosage forms. METHODS: Optimum INHAA formation was obtained at 68 °C and 1.97 mL 0.05 M 9-AA for 3 h using a chemometric tool which is one of the green analytical chemistry strategies. INHAA was separated on a C18 reversed-phase column in conjunction with an isocratic elution of a mobile phase composed of methanol-Milli-Q grade water and detected by fluorescence detection (FL) at excitation (390 nm) and emission (489 nm) wavelengths. RESULTS: The method was linear over concentration range that varies between 0.5 and 20 µg/mL INH. The limit of detection (LOD) and limit of quantitation (LOQ) were estimated based on three and ten times the baseline noise and were found to be 0.11 µg/mL and 0.33 µg/mL INH, respectively. The optimized HPLC-FL parameters were applied to the analysis of drug dosage forms INH containing for quality control purposes. CONCLUSION: A new HPLC-FL method was developed for the analysis of INH in drug dosage forms, which saves time, effort and chemicals in the experimental design. GRAPHICAL ABSTRACT: [Image: see text] |
format | Online Article Text |
id | pubmed-10155667 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Springer International Publishing |
record_format | MEDLINE/PubMed |
spelling | pubmed-101556672023-05-09 Determination of Isoniazid Gained Fluorescent with 9-Anthraldehyde by HPLC-FL Method in Dosage Forms Demirkaya Miloglu, Fatma Bayrak, Burak Kadioglu, Yucel Chemistry Africa Original Article PURPOSE: Tuberculosis is a chronic necrotizing bacterial infection caused by Mycobacterium tuberculosis, which has not lost its prevalence in the society from the past to the present. Isoniazid (INH) is an important drug used in the treatment of tuberculosis and is used for all forms of tuberculosis caused by Mycobacterium tuberculosis, unless there is resistance. This study is aimed to develop and validate a new HPLC with fluorescence detector (HPLC-FL) based on the formation of a coloured product (9-anthraldehyde isonicotinoyl hydrazone, INHAA) resulting from the condensation reaction of INH with 9-anthraldehyde(9-AA) for the determination of INH in dosage forms. METHODS: Optimum INHAA formation was obtained at 68 °C and 1.97 mL 0.05 M 9-AA for 3 h using a chemometric tool which is one of the green analytical chemistry strategies. INHAA was separated on a C18 reversed-phase column in conjunction with an isocratic elution of a mobile phase composed of methanol-Milli-Q grade water and detected by fluorescence detection (FL) at excitation (390 nm) and emission (489 nm) wavelengths. RESULTS: The method was linear over concentration range that varies between 0.5 and 20 µg/mL INH. The limit of detection (LOD) and limit of quantitation (LOQ) were estimated based on three and ten times the baseline noise and were found to be 0.11 µg/mL and 0.33 µg/mL INH, respectively. The optimized HPLC-FL parameters were applied to the analysis of drug dosage forms INH containing for quality control purposes. CONCLUSION: A new HPLC-FL method was developed for the analysis of INH in drug dosage forms, which saves time, effort and chemicals in the experimental design. GRAPHICAL ABSTRACT: [Image: see text] Springer International Publishing 2023-05-03 /pmc/articles/PMC10155667/ http://dx.doi.org/10.1007/s42250-023-00676-6 Text en © The Tunisian Chemical Society and Springer Nature Switzerland AG 2023, Springer Nature or its licensor (e.g. a society or other partner) holds exclusive rights to this article under a publishing agreement with the author(s) or other rightsholder(s); author self-archiving of the accepted manuscript version of this article is solely governed by the terms of such publishing agreement and applicable law. This article is made available via the PMC Open Access Subset for unrestricted research re-use and secondary analysis in any form or by any means with acknowledgement of the original source. These permissions are granted for the duration of the World Health Organization (WHO) declaration of COVID-19 as a global pandemic. |
spellingShingle | Original Article Demirkaya Miloglu, Fatma Bayrak, Burak Kadioglu, Yucel Determination of Isoniazid Gained Fluorescent with 9-Anthraldehyde by HPLC-FL Method in Dosage Forms |
title | Determination of Isoniazid Gained Fluorescent with 9-Anthraldehyde by HPLC-FL Method in Dosage Forms |
title_full | Determination of Isoniazid Gained Fluorescent with 9-Anthraldehyde by HPLC-FL Method in Dosage Forms |
title_fullStr | Determination of Isoniazid Gained Fluorescent with 9-Anthraldehyde by HPLC-FL Method in Dosage Forms |
title_full_unstemmed | Determination of Isoniazid Gained Fluorescent with 9-Anthraldehyde by HPLC-FL Method in Dosage Forms |
title_short | Determination of Isoniazid Gained Fluorescent with 9-Anthraldehyde by HPLC-FL Method in Dosage Forms |
title_sort | determination of isoniazid gained fluorescent with 9-anthraldehyde by hplc-fl method in dosage forms |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10155667/ http://dx.doi.org/10.1007/s42250-023-00676-6 |
work_keys_str_mv | AT demirkayamiloglufatma determinationofisoniazidgainedfluorescentwith9anthraldehydebyhplcflmethodindosageforms AT bayrakburak determinationofisoniazidgainedfluorescentwith9anthraldehydebyhplcflmethodindosageforms AT kadiogluyucel determinationofisoniazidgainedfluorescentwith9anthraldehydebyhplcflmethodindosageforms |