Development and application of a thin‐film molecularly imprinted polymer for the measurement of mycophenolic acid in human plasma

BACKGROUND: Mycophenolic acid (MPA) is used to suppress the immune response following organ transplantation; however, complex pharmacokinetic behavior and a large interpersonal variability necessitate therapeutic drug monitoring. To overcome the limitations of current sample preparation techniques,...

Descripción completa

Detalles Bibliográficos
Autores principales: Langille, Evan, Bottaro, Christina S.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: John Wiley and Sons Inc. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10156102/
https://www.ncbi.nlm.nih.gov/pubmed/37032424
http://dx.doi.org/10.1002/jcla.24864
_version_ 1785036469566439424
author Langille, Evan
Bottaro, Christina S.
author_facet Langille, Evan
Bottaro, Christina S.
author_sort Langille, Evan
collection PubMed
description BACKGROUND: Mycophenolic acid (MPA) is used to suppress the immune response following organ transplantation; however, complex pharmacokinetic behavior and a large interpersonal variability necessitate therapeutic drug monitoring. To overcome the limitations of current sample preparation techniques, we present a novel thin‐film molecularly imprinted polymer (TF‐MIP) extraction device as part of a simple, sensitive, and fast method for analysis of MPA from human plasma. METHODS: Mycophenolic acid is extracted from plasma using a tailor‐made TF‐MIP that is subsequently desorbed into an organic solvent system compatible with mass spectrometry. The MIP yielded higher recovery of MPA relative to a corresponding non‐imprinted polymer. The method allows for the determination of MPA in 45 min including analysis time and can be scaled for high throughput to process as many as 96 samples per hour. RESULTS: The method gave an LOD of 0.3 ng mL(−1) and was linear from 5 to 250 ng mL(−1). Patient plasma samples (35 μL) were diluted using charcoal‐stripped pooled plasma to a final extraction volume of 700 μL; when MPA in patient plasma is high, this ratio can easily be adjusted to ensure samples are within the method linear range. Intra‐ and inter‐day variability were 13.8% and 4.3% (at 15 ng mL(−1)) and 13.5% and 11.0% (at 85 ng mL(−1)), respectively (n = 3); inter‐device variability was 9.6% (n = 10). CONCLUSIONS: Low inter‐device variability makes these devices suitable for single use in a clinical setting, and the fast and robust method is suitable for therapeutic drug monitoring, where throughput and time‐to‐result are critical.
format Online
Article
Text
id pubmed-10156102
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher John Wiley and Sons Inc.
record_format MEDLINE/PubMed
spelling pubmed-101561022023-05-04 Development and application of a thin‐film molecularly imprinted polymer for the measurement of mycophenolic acid in human plasma Langille, Evan Bottaro, Christina S. J Clin Lab Anal Research Articles BACKGROUND: Mycophenolic acid (MPA) is used to suppress the immune response following organ transplantation; however, complex pharmacokinetic behavior and a large interpersonal variability necessitate therapeutic drug monitoring. To overcome the limitations of current sample preparation techniques, we present a novel thin‐film molecularly imprinted polymer (TF‐MIP) extraction device as part of a simple, sensitive, and fast method for analysis of MPA from human plasma. METHODS: Mycophenolic acid is extracted from plasma using a tailor‐made TF‐MIP that is subsequently desorbed into an organic solvent system compatible with mass spectrometry. The MIP yielded higher recovery of MPA relative to a corresponding non‐imprinted polymer. The method allows for the determination of MPA in 45 min including analysis time and can be scaled for high throughput to process as many as 96 samples per hour. RESULTS: The method gave an LOD of 0.3 ng mL(−1) and was linear from 5 to 250 ng mL(−1). Patient plasma samples (35 μL) were diluted using charcoal‐stripped pooled plasma to a final extraction volume of 700 μL; when MPA in patient plasma is high, this ratio can easily be adjusted to ensure samples are within the method linear range. Intra‐ and inter‐day variability were 13.8% and 4.3% (at 15 ng mL(−1)) and 13.5% and 11.0% (at 85 ng mL(−1)), respectively (n = 3); inter‐device variability was 9.6% (n = 10). CONCLUSIONS: Low inter‐device variability makes these devices suitable for single use in a clinical setting, and the fast and robust method is suitable for therapeutic drug monitoring, where throughput and time‐to‐result are critical. John Wiley and Sons Inc. 2023-04-09 /pmc/articles/PMC10156102/ /pubmed/37032424 http://dx.doi.org/10.1002/jcla.24864 Text en © 2023 The Authors. Journal of Clinical Laboratory Analysis published by Wiley Periodicals LLC. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Articles
Langille, Evan
Bottaro, Christina S.
Development and application of a thin‐film molecularly imprinted polymer for the measurement of mycophenolic acid in human plasma
title Development and application of a thin‐film molecularly imprinted polymer for the measurement of mycophenolic acid in human plasma
title_full Development and application of a thin‐film molecularly imprinted polymer for the measurement of mycophenolic acid in human plasma
title_fullStr Development and application of a thin‐film molecularly imprinted polymer for the measurement of mycophenolic acid in human plasma
title_full_unstemmed Development and application of a thin‐film molecularly imprinted polymer for the measurement of mycophenolic acid in human plasma
title_short Development and application of a thin‐film molecularly imprinted polymer for the measurement of mycophenolic acid in human plasma
title_sort development and application of a thin‐film molecularly imprinted polymer for the measurement of mycophenolic acid in human plasma
topic Research Articles
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10156102/
https://www.ncbi.nlm.nih.gov/pubmed/37032424
http://dx.doi.org/10.1002/jcla.24864
work_keys_str_mv AT langilleevan developmentandapplicationofathinfilmmolecularlyimprintedpolymerforthemeasurementofmycophenolicacidinhumanplasma
AT bottarochristinas developmentandapplicationofathinfilmmolecularlyimprintedpolymerforthemeasurementofmycophenolicacidinhumanplasma