The Complication of a Retained Broken Distal Interlocking Screw Within a Cephalomedullary Nail During Conversion Hip Arthroplasty: A Case Report

In patients who undergo femoral fracture fixation with a cephalomedullary nail, the breakage of one or more of the distal interlocking screws is a well-described phenomenon. The presence of a broken interlocking screw in patients who require the removal of their cephalomedullary nail presents a uniq...

Descripción completa

Detalles Bibliográficos
Autores principales: Panchal, Olivia, Schultz, Matthew J, Lutz, Rex W, Smith, Eric B, Deirmengian, Gregory K
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10156128/
https://www.ncbi.nlm.nih.gov/pubmed/37153273
http://dx.doi.org/10.7759/cureus.37075
_version_ 1785036475698511872
author Panchal, Olivia
Schultz, Matthew J
Lutz, Rex W
Smith, Eric B
Deirmengian, Gregory K
author_facet Panchal, Olivia
Schultz, Matthew J
Lutz, Rex W
Smith, Eric B
Deirmengian, Gregory K
author_sort Panchal, Olivia
collection PubMed
description In patients who undergo femoral fracture fixation with a cephalomedullary nail, the breakage of one or more of the distal interlocking screws is a well-described phenomenon. The presence of a broken interlocking screw in patients who require the removal of their cephalomedullary nail presents a unique challenge. The broken interlocking screw may be retrieved, or the screw may be retained if it is not engaged within the nail and the nail can safely be removed while leaving the broken screw fragment behind. We report a hip conversion arthroplasty case with a broken interlocking screw where the nail was removed with ease and the broken screw was assumed to have been left behind. Cerclage wires were placed for an apparent proximal femoral fracture. Postoperative X-rays demonstrated a large lucency tracking from the prior location of the distal interlocking screw to the calcar region. This finding made it evident that the broken screw had been retained in the nail and was dragged up the femur upon nail removal, causing a large gouge spanning the entire femur.
format Online
Article
Text
id pubmed-10156128
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-101561282023-05-04 The Complication of a Retained Broken Distal Interlocking Screw Within a Cephalomedullary Nail During Conversion Hip Arthroplasty: A Case Report Panchal, Olivia Schultz, Matthew J Lutz, Rex W Smith, Eric B Deirmengian, Gregory K Cureus Orthopedics In patients who undergo femoral fracture fixation with a cephalomedullary nail, the breakage of one or more of the distal interlocking screws is a well-described phenomenon. The presence of a broken interlocking screw in patients who require the removal of their cephalomedullary nail presents a unique challenge. The broken interlocking screw may be retrieved, or the screw may be retained if it is not engaged within the nail and the nail can safely be removed while leaving the broken screw fragment behind. We report a hip conversion arthroplasty case with a broken interlocking screw where the nail was removed with ease and the broken screw was assumed to have been left behind. Cerclage wires were placed for an apparent proximal femoral fracture. Postoperative X-rays demonstrated a large lucency tracking from the prior location of the distal interlocking screw to the calcar region. This finding made it evident that the broken screw had been retained in the nail and was dragged up the femur upon nail removal, causing a large gouge spanning the entire femur. Cureus 2023-04-03 /pmc/articles/PMC10156128/ /pubmed/37153273 http://dx.doi.org/10.7759/cureus.37075 Text en Copyright © 2023, Panchal et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Orthopedics
Panchal, Olivia
Schultz, Matthew J
Lutz, Rex W
Smith, Eric B
Deirmengian, Gregory K
The Complication of a Retained Broken Distal Interlocking Screw Within a Cephalomedullary Nail During Conversion Hip Arthroplasty: A Case Report
title The Complication of a Retained Broken Distal Interlocking Screw Within a Cephalomedullary Nail During Conversion Hip Arthroplasty: A Case Report
title_full The Complication of a Retained Broken Distal Interlocking Screw Within a Cephalomedullary Nail During Conversion Hip Arthroplasty: A Case Report
title_fullStr The Complication of a Retained Broken Distal Interlocking Screw Within a Cephalomedullary Nail During Conversion Hip Arthroplasty: A Case Report
title_full_unstemmed The Complication of a Retained Broken Distal Interlocking Screw Within a Cephalomedullary Nail During Conversion Hip Arthroplasty: A Case Report
title_short The Complication of a Retained Broken Distal Interlocking Screw Within a Cephalomedullary Nail During Conversion Hip Arthroplasty: A Case Report
title_sort complication of a retained broken distal interlocking screw within a cephalomedullary nail during conversion hip arthroplasty: a case report
topic Orthopedics
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10156128/
https://www.ncbi.nlm.nih.gov/pubmed/37153273
http://dx.doi.org/10.7759/cureus.37075
work_keys_str_mv AT panchalolivia thecomplicationofaretainedbrokendistalinterlockingscrewwithinacephalomedullarynailduringconversionhiparthroplastyacasereport
AT schultzmatthewj thecomplicationofaretainedbrokendistalinterlockingscrewwithinacephalomedullarynailduringconversionhiparthroplastyacasereport
AT lutzrexw thecomplicationofaretainedbrokendistalinterlockingscrewwithinacephalomedullarynailduringconversionhiparthroplastyacasereport
AT smithericb thecomplicationofaretainedbrokendistalinterlockingscrewwithinacephalomedullarynailduringconversionhiparthroplastyacasereport
AT deirmengiangregoryk thecomplicationofaretainedbrokendistalinterlockingscrewwithinacephalomedullarynailduringconversionhiparthroplastyacasereport
AT panchalolivia complicationofaretainedbrokendistalinterlockingscrewwithinacephalomedullarynailduringconversionhiparthroplastyacasereport
AT schultzmatthewj complicationofaretainedbrokendistalinterlockingscrewwithinacephalomedullarynailduringconversionhiparthroplastyacasereport
AT lutzrexw complicationofaretainedbrokendistalinterlockingscrewwithinacephalomedullarynailduringconversionhiparthroplastyacasereport
AT smithericb complicationofaretainedbrokendistalinterlockingscrewwithinacephalomedullarynailduringconversionhiparthroplastyacasereport
AT deirmengiangregoryk complicationofaretainedbrokendistalinterlockingscrewwithinacephalomedullarynailduringconversionhiparthroplastyacasereport