Cargando…

A Comparative Evaluation of the Apically Extruded Debris from Root Canals Prepared by R-Motion NiTi File System

BACKGROUND: Apically extruded debris (AED) is an inherent concern during root canal treatment for both endodontists and general practitioners. The present study investigates the AED of the novel R-Motion single-file reciprocating system compared to standard single reciprocating and multifile rotary...

Descripción completa

Detalles Bibliográficos
Autores principales: Al-Saffar, Farah B., Al-Gharrawi, Hikmet A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Hindawi 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10156454/
https://www.ncbi.nlm.nih.gov/pubmed/37152476
http://dx.doi.org/10.1155/2023/5731248
_version_ 1785036543196397568
author Al-Saffar, Farah B.
Al-Gharrawi, Hikmet A.
author_facet Al-Saffar, Farah B.
Al-Gharrawi, Hikmet A.
author_sort Al-Saffar, Farah B.
collection PubMed
description BACKGROUND: Apically extruded debris (AED) is an inherent concern during root canal treatment for both endodontists and general practitioners. The present study investigates the AED of the novel R-Motion single-file reciprocating system compared to standard single reciprocating and multifile rotary systems. MATERIALS AND METHODS: Fifty-six moderately curved palatal roots of upper maxillary first molars were selected for the present study. The samples were then divided randomly into four groups (n = 14)— Group I: R-motion (RM), Group II: WaveOne Gold (WOG), Group III: ProTaper Next (PTN), and Group IV: HyFlex EDM (HFEDM). The researcher has modified Myers and Montgomery's method to simulate human body temperature. Vials were used to collect debris and weighted using a 0.00001 sensitive balance before and after instrumentation. The instrumentation of all experimented groups was done at 37°C, terminated at master apical file #25. An auto syringe with a side vented needle was used to deliver 8 ml of deionized water for irrigation of each sample during preparation. Vials were stored in a dry sealed desiccator which contained CaSO(4) crystals, for 24 hr before weighing. The weight of the collected debris was obtained by subtracting the preinstrumentation weight from the postinstrumentation weight for each vial. The Kruskal–Wallis and Mann–Whitney U tests were performed to analyse the statistical difference in the amount of debris between the tested groups at a 0.05 significance level. RESULTS: The RM system produced less debris extrusion than all tested groups, with a significant difference between the former and the WOG and the PTN systems. However, WOG, PTN, and HFEDM showed no statistically significant difference in the amount of AED. CONCLUSION: All tested groups produced apical debris in different amounts. The RM produced substantially less AED than WOG and PTN. Meanwhile, WOG, PTN, and HFEDM caused a comparable amount of AED.
format Online
Article
Text
id pubmed-10156454
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Hindawi
record_format MEDLINE/PubMed
spelling pubmed-101564542023-05-04 A Comparative Evaluation of the Apically Extruded Debris from Root Canals Prepared by R-Motion NiTi File System Al-Saffar, Farah B. Al-Gharrawi, Hikmet A. Int J Dent Research Article BACKGROUND: Apically extruded debris (AED) is an inherent concern during root canal treatment for both endodontists and general practitioners. The present study investigates the AED of the novel R-Motion single-file reciprocating system compared to standard single reciprocating and multifile rotary systems. MATERIALS AND METHODS: Fifty-six moderately curved palatal roots of upper maxillary first molars were selected for the present study. The samples were then divided randomly into four groups (n = 14)— Group I: R-motion (RM), Group II: WaveOne Gold (WOG), Group III: ProTaper Next (PTN), and Group IV: HyFlex EDM (HFEDM). The researcher has modified Myers and Montgomery's method to simulate human body temperature. Vials were used to collect debris and weighted using a 0.00001 sensitive balance before and after instrumentation. The instrumentation of all experimented groups was done at 37°C, terminated at master apical file #25. An auto syringe with a side vented needle was used to deliver 8 ml of deionized water for irrigation of each sample during preparation. Vials were stored in a dry sealed desiccator which contained CaSO(4) crystals, for 24 hr before weighing. The weight of the collected debris was obtained by subtracting the preinstrumentation weight from the postinstrumentation weight for each vial. The Kruskal–Wallis and Mann–Whitney U tests were performed to analyse the statistical difference in the amount of debris between the tested groups at a 0.05 significance level. RESULTS: The RM system produced less debris extrusion than all tested groups, with a significant difference between the former and the WOG and the PTN systems. However, WOG, PTN, and HFEDM showed no statistically significant difference in the amount of AED. CONCLUSION: All tested groups produced apical debris in different amounts. The RM produced substantially less AED than WOG and PTN. Meanwhile, WOG, PTN, and HFEDM caused a comparable amount of AED. Hindawi 2023-04-26 /pmc/articles/PMC10156454/ /pubmed/37152476 http://dx.doi.org/10.1155/2023/5731248 Text en Copyright © 2023 Farah B. Al-Saffar and Hikmet A. Al-Gharrawi. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
spellingShingle Research Article
Al-Saffar, Farah B.
Al-Gharrawi, Hikmet A.
A Comparative Evaluation of the Apically Extruded Debris from Root Canals Prepared by R-Motion NiTi File System
title A Comparative Evaluation of the Apically Extruded Debris from Root Canals Prepared by R-Motion NiTi File System
title_full A Comparative Evaluation of the Apically Extruded Debris from Root Canals Prepared by R-Motion NiTi File System
title_fullStr A Comparative Evaluation of the Apically Extruded Debris from Root Canals Prepared by R-Motion NiTi File System
title_full_unstemmed A Comparative Evaluation of the Apically Extruded Debris from Root Canals Prepared by R-Motion NiTi File System
title_short A Comparative Evaluation of the Apically Extruded Debris from Root Canals Prepared by R-Motion NiTi File System
title_sort comparative evaluation of the apically extruded debris from root canals prepared by r-motion niti file system
topic Research Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10156454/
https://www.ncbi.nlm.nih.gov/pubmed/37152476
http://dx.doi.org/10.1155/2023/5731248
work_keys_str_mv AT alsaffarfarahb acomparativeevaluationoftheapicallyextrudeddebrisfromrootcanalspreparedbyrmotionnitifilesystem
AT algharrawihikmeta acomparativeevaluationoftheapicallyextrudeddebrisfromrootcanalspreparedbyrmotionnitifilesystem
AT alsaffarfarahb comparativeevaluationoftheapicallyextrudeddebrisfromrootcanalspreparedbyrmotionnitifilesystem
AT algharrawihikmeta comparativeevaluationoftheapicallyextrudeddebrisfromrootcanalspreparedbyrmotionnitifilesystem