Cargando…
Effect of bioelectrical impedance technology on the prognosis of dialysis patients: a meta-analysis of randomized controlled trials
Managing patient ‘dry weight’ according to clinical standards has deficiencies. Research has focused on the effectiveness of using bioelectrical impedance technology for fluid management in dialysis patients. Whether bioelectrical impedance monitoring can improve dialysis patients prognoses remain c...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Taylor & Francis
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10158555/ https://www.ncbi.nlm.nih.gov/pubmed/37133857 http://dx.doi.org/10.1080/0886022X.2023.2203247 |
_version_ | 1785036953635258368 |
---|---|
author | Yang, Kaibi Pan, Shujun Yang, Nan Wu, Juan Liu, Yueming He, Qiang |
author_facet | Yang, Kaibi Pan, Shujun Yang, Nan Wu, Juan Liu, Yueming He, Qiang |
author_sort | Yang, Kaibi |
collection | PubMed |
description | Managing patient ‘dry weight’ according to clinical standards has deficiencies. Research has focused on the effectiveness of using bioelectrical impedance technology for fluid management in dialysis patients. Whether bioelectrical impedance monitoring can improve dialysis patients prognoses remain controversial. We performed a meta-analysis of randomized controlled trials to determine whether bioelectrical impedance was effective in improving dialysis patients prognoses. The primary outcome was all-cause mortality (13.6 ± 9.1 months). Secondary outcomes were left ventricular mass index (LVMI), arterial stiffness assessed using Pulse Wave Velocity (PWV), and N-terminal brain natriuretic peptide precursor (NT-proBNP). Of 4,641 citations retrieved, we identified 15 eligible trials involving 2763 patients divided into experimental (n = 1386) and control (n = 1377) groups. In 14 studies with mortality data, the meta-analysis showed that bioelectrical impedance intervention reduced the risk of all-cause mortality (rate ratios [RR]: 0.71; 95% confidence interval [CI]: 0.51, 0.99; p = .05; I2 = 1%). Subgroup analysis of patients on hemodialysis (RR: 0.72; 95% CI: 0.42, 1.22; p = .22) and peritoneal dialysis (RR: 0.62; 95% CI: 0.35, 1.07; p = .08) showed no significant mortality difference between intervention and control groups. It reduced the risk of all-cause mortality in the Asian population (RR: 0.52; p = .02), and reduced NT-proBNP (mean difference [MD]: −1495.73; p = 0.002; I(2)=0%) and PWV (MD: −1.55; p = .01; I(2)=89%). Bioelectrical impedance intervention reduced the LVMI in hemodialysis patients (MD: −12.69; p < .0001; I(2)=0%). Our analysis shows that in dialysis patients, bioelectrical impedance technology intervention could reduce, but not eliminate, the risk of all-cause mortality. Overall, this technology can improve the prognosis of dialysis patients. |
format | Online Article Text |
id | pubmed-10158555 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Taylor & Francis |
record_format | MEDLINE/PubMed |
spelling | pubmed-101585552023-05-05 Effect of bioelectrical impedance technology on the prognosis of dialysis patients: a meta-analysis of randomized controlled trials Yang, Kaibi Pan, Shujun Yang, Nan Wu, Juan Liu, Yueming He, Qiang Ren Fail State-of-the-Art Review Managing patient ‘dry weight’ according to clinical standards has deficiencies. Research has focused on the effectiveness of using bioelectrical impedance technology for fluid management in dialysis patients. Whether bioelectrical impedance monitoring can improve dialysis patients prognoses remain controversial. We performed a meta-analysis of randomized controlled trials to determine whether bioelectrical impedance was effective in improving dialysis patients prognoses. The primary outcome was all-cause mortality (13.6 ± 9.1 months). Secondary outcomes were left ventricular mass index (LVMI), arterial stiffness assessed using Pulse Wave Velocity (PWV), and N-terminal brain natriuretic peptide precursor (NT-proBNP). Of 4,641 citations retrieved, we identified 15 eligible trials involving 2763 patients divided into experimental (n = 1386) and control (n = 1377) groups. In 14 studies with mortality data, the meta-analysis showed that bioelectrical impedance intervention reduced the risk of all-cause mortality (rate ratios [RR]: 0.71; 95% confidence interval [CI]: 0.51, 0.99; p = .05; I2 = 1%). Subgroup analysis of patients on hemodialysis (RR: 0.72; 95% CI: 0.42, 1.22; p = .22) and peritoneal dialysis (RR: 0.62; 95% CI: 0.35, 1.07; p = .08) showed no significant mortality difference between intervention and control groups. It reduced the risk of all-cause mortality in the Asian population (RR: 0.52; p = .02), and reduced NT-proBNP (mean difference [MD]: −1495.73; p = 0.002; I(2)=0%) and PWV (MD: −1.55; p = .01; I(2)=89%). Bioelectrical impedance intervention reduced the LVMI in hemodialysis patients (MD: −12.69; p < .0001; I(2)=0%). Our analysis shows that in dialysis patients, bioelectrical impedance technology intervention could reduce, but not eliminate, the risk of all-cause mortality. Overall, this technology can improve the prognosis of dialysis patients. Taylor & Francis 2023-05-03 /pmc/articles/PMC10158555/ /pubmed/37133857 http://dx.doi.org/10.1080/0886022X.2023.2203247 Text en © 2023 The Author(s). Published by Informa UK Limited, trading as Taylor & Francis Group. https://creativecommons.org/licenses/by/4.0/This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) ), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. The terms on which this article has been published allow the posting of the Accepted Manuscript in a repository by the author(s) or with their consent. |
spellingShingle | State-of-the-Art Review Yang, Kaibi Pan, Shujun Yang, Nan Wu, Juan Liu, Yueming He, Qiang Effect of bioelectrical impedance technology on the prognosis of dialysis patients: a meta-analysis of randomized controlled trials |
title | Effect of bioelectrical impedance technology on the prognosis of dialysis patients: a meta-analysis of randomized controlled trials |
title_full | Effect of bioelectrical impedance technology on the prognosis of dialysis patients: a meta-analysis of randomized controlled trials |
title_fullStr | Effect of bioelectrical impedance technology on the prognosis of dialysis patients: a meta-analysis of randomized controlled trials |
title_full_unstemmed | Effect of bioelectrical impedance technology on the prognosis of dialysis patients: a meta-analysis of randomized controlled trials |
title_short | Effect of bioelectrical impedance technology on the prognosis of dialysis patients: a meta-analysis of randomized controlled trials |
title_sort | effect of bioelectrical impedance technology on the prognosis of dialysis patients: a meta-analysis of randomized controlled trials |
topic | State-of-the-Art Review |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10158555/ https://www.ncbi.nlm.nih.gov/pubmed/37133857 http://dx.doi.org/10.1080/0886022X.2023.2203247 |
work_keys_str_mv | AT yangkaibi effectofbioelectricalimpedancetechnologyontheprognosisofdialysispatientsametaanalysisofrandomizedcontrolledtrials AT panshujun effectofbioelectricalimpedancetechnologyontheprognosisofdialysispatientsametaanalysisofrandomizedcontrolledtrials AT yangnan effectofbioelectricalimpedancetechnologyontheprognosisofdialysispatientsametaanalysisofrandomizedcontrolledtrials AT wujuan effectofbioelectricalimpedancetechnologyontheprognosisofdialysispatientsametaanalysisofrandomizedcontrolledtrials AT liuyueming effectofbioelectricalimpedancetechnologyontheprognosisofdialysispatientsametaanalysisofrandomizedcontrolledtrials AT heqiang effectofbioelectricalimpedancetechnologyontheprognosisofdialysispatientsametaanalysisofrandomizedcontrolledtrials |