Cargando…

Diagnostic compatibility of various fixed orthodontic retainers for head/neck MRI and dental MRI

OBJECTIVES: To evaluate the diagnostic MRI compatibility of different fixed orthodontic retainers using a high-resolution 3D-sequence optimized for artifact reduction. MATERIALS AND METHODS: Maxillary and mandibular retainers made of five different materials were scanned in vitro and in vivo at 3 T...

Descripción completa

Detalles Bibliográficos
Autores principales: Juerchott, Alexander, Roser, Christoph J., Saleem, Muhammad Abdullah, Nittka, Mathias, Lux, Christopher J., Heiland, Sabine, Bendszus, Martin, Hilgenfeld, Tim
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Springer Berlin Heidelberg 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10160193/
https://www.ncbi.nlm.nih.gov/pubmed/36640179
http://dx.doi.org/10.1007/s00784-023-04861-2
_version_ 1785037236952104960
author Juerchott, Alexander
Roser, Christoph J.
Saleem, Muhammad Abdullah
Nittka, Mathias
Lux, Christopher J.
Heiland, Sabine
Bendszus, Martin
Hilgenfeld, Tim
author_facet Juerchott, Alexander
Roser, Christoph J.
Saleem, Muhammad Abdullah
Nittka, Mathias
Lux, Christopher J.
Heiland, Sabine
Bendszus, Martin
Hilgenfeld, Tim
author_sort Juerchott, Alexander
collection PubMed
description OBJECTIVES: To evaluate the diagnostic MRI compatibility of different fixed orthodontic retainers using a high-resolution 3D-sequence optimized for artifact reduction. MATERIALS AND METHODS: Maxillary and mandibular retainers made of five different materials were scanned in vitro and in vivo at 3 T MRI using an MSVAT-SPACE sequence. In vitro, artifact volumes were determined for all maxillary and mandibular retainers (AV(max); AV(mand)). In vivo, two independent observers quantified the extent of artifacts based on the visibility of 124 dental and non-dental landmarks using a five-point rating scale (1 = excellent, 2 = good, 3 = acceptable, 4 = poor, 5 = not visible). RESULTS: Rectangular-steel retainers caused the largest artifacts (AV(max)/AV(mand): 18,060/15,879 mm(3)) and considerable diagnostic impairment in vivo (mean landmark visibility score ± SD inside/outside the retainer areas: 4.8 ± 0.8/2.9 ± 1.6). Smaller, but diagnostically relevant artifacts were observed for twistflex steel retainers (437/6317 mm(3), 3.1 ± 1.7/1.3 ± 0.7). All retainers made of precious-alloy materials produced only very small artifact volumes (titanium grade 1: 70/46 mm(3), titanium grade 5: 47/35 mm(3), gold: 23/21 mm(3)) without any impact on image quality in vivo (each retainer: visibility scores of 1.0 ± 0.0 for all landmarks inside and outside the retainer areas). CONCLUSIONS: In contrast to steel retainers, titanium and gold retainers are fully compatible for both head/neck and dental MRI when using MSVAT-SPACE. CLINICAL RELEVANCE: This study demonstrates that titanium and gold retainers do not impair the diagnostic quality of head/neck and dental MRI when applying an appropriate artifact-reduction technique. Steel retainers, however, are not suitable for dental MRI and can severely impair image quality in head/neck MRI of the oral cavity.
format Online
Article
Text
id pubmed-10160193
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Springer Berlin Heidelberg
record_format MEDLINE/PubMed
spelling pubmed-101601932023-05-06 Diagnostic compatibility of various fixed orthodontic retainers for head/neck MRI and dental MRI Juerchott, Alexander Roser, Christoph J. Saleem, Muhammad Abdullah Nittka, Mathias Lux, Christopher J. Heiland, Sabine Bendszus, Martin Hilgenfeld, Tim Clin Oral Investig Research OBJECTIVES: To evaluate the diagnostic MRI compatibility of different fixed orthodontic retainers using a high-resolution 3D-sequence optimized for artifact reduction. MATERIALS AND METHODS: Maxillary and mandibular retainers made of five different materials were scanned in vitro and in vivo at 3 T MRI using an MSVAT-SPACE sequence. In vitro, artifact volumes were determined for all maxillary and mandibular retainers (AV(max); AV(mand)). In vivo, two independent observers quantified the extent of artifacts based on the visibility of 124 dental and non-dental landmarks using a five-point rating scale (1 = excellent, 2 = good, 3 = acceptable, 4 = poor, 5 = not visible). RESULTS: Rectangular-steel retainers caused the largest artifacts (AV(max)/AV(mand): 18,060/15,879 mm(3)) and considerable diagnostic impairment in vivo (mean landmark visibility score ± SD inside/outside the retainer areas: 4.8 ± 0.8/2.9 ± 1.6). Smaller, but diagnostically relevant artifacts were observed for twistflex steel retainers (437/6317 mm(3), 3.1 ± 1.7/1.3 ± 0.7). All retainers made of precious-alloy materials produced only very small artifact volumes (titanium grade 1: 70/46 mm(3), titanium grade 5: 47/35 mm(3), gold: 23/21 mm(3)) without any impact on image quality in vivo (each retainer: visibility scores of 1.0 ± 0.0 for all landmarks inside and outside the retainer areas). CONCLUSIONS: In contrast to steel retainers, titanium and gold retainers are fully compatible for both head/neck and dental MRI when using MSVAT-SPACE. CLINICAL RELEVANCE: This study demonstrates that titanium and gold retainers do not impair the diagnostic quality of head/neck and dental MRI when applying an appropriate artifact-reduction technique. Steel retainers, however, are not suitable for dental MRI and can severely impair image quality in head/neck MRI of the oral cavity. Springer Berlin Heidelberg 2023-01-14 2023 /pmc/articles/PMC10160193/ /pubmed/36640179 http://dx.doi.org/10.1007/s00784-023-04861-2 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Research
Juerchott, Alexander
Roser, Christoph J.
Saleem, Muhammad Abdullah
Nittka, Mathias
Lux, Christopher J.
Heiland, Sabine
Bendszus, Martin
Hilgenfeld, Tim
Diagnostic compatibility of various fixed orthodontic retainers for head/neck MRI and dental MRI
title Diagnostic compatibility of various fixed orthodontic retainers for head/neck MRI and dental MRI
title_full Diagnostic compatibility of various fixed orthodontic retainers for head/neck MRI and dental MRI
title_fullStr Diagnostic compatibility of various fixed orthodontic retainers for head/neck MRI and dental MRI
title_full_unstemmed Diagnostic compatibility of various fixed orthodontic retainers for head/neck MRI and dental MRI
title_short Diagnostic compatibility of various fixed orthodontic retainers for head/neck MRI and dental MRI
title_sort diagnostic compatibility of various fixed orthodontic retainers for head/neck mri and dental mri
topic Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10160193/
https://www.ncbi.nlm.nih.gov/pubmed/36640179
http://dx.doi.org/10.1007/s00784-023-04861-2
work_keys_str_mv AT juerchottalexander diagnosticcompatibilityofvariousfixedorthodonticretainersforheadneckmrianddentalmri
AT roserchristophj diagnosticcompatibilityofvariousfixedorthodonticretainersforheadneckmrianddentalmri
AT saleemmuhammadabdullah diagnosticcompatibilityofvariousfixedorthodonticretainersforheadneckmrianddentalmri
AT nittkamathias diagnosticcompatibilityofvariousfixedorthodonticretainersforheadneckmrianddentalmri
AT luxchristopherj diagnosticcompatibilityofvariousfixedorthodonticretainersforheadneckmrianddentalmri
AT heilandsabine diagnosticcompatibilityofvariousfixedorthodonticretainersforheadneckmrianddentalmri
AT bendszusmartin diagnosticcompatibilityofvariousfixedorthodonticretainersforheadneckmrianddentalmri
AT hilgenfeldtim diagnosticcompatibilityofvariousfixedorthodonticretainersforheadneckmrianddentalmri