Cargando…
Pseudo loss of capture on 12 lead electrocardiogram in patient with an implantable cardiac defibrillator
This case report presents a 70-year-old-male, brought in by ambulance for assessment of chest pain and presyncope, with a paced ECG showing possible non-capture following ventricular pacing spikes. This was demonstrated to be pseudo non-capture with a 12-lead electrocardiogram performed in emergency...
Autores principales: | , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Elsevier
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10160749/ https://www.ncbi.nlm.nih.gov/pubmed/36822468 http://dx.doi.org/10.1016/j.ipej.2023.02.003 |
Sumario: | This case report presents a 70-year-old-male, brought in by ambulance for assessment of chest pain and presyncope, with a paced ECG showing possible non-capture following ventricular pacing spikes. This was demonstrated to be pseudo non-capture with a 12-lead electrocardiogram performed in emergency and a device interrogation demonstrating ventricular capture. |
---|