Cargando…
Stability and reproducibility comparisons between deep inspiration breath‐hold techniques for left‐sided breast cancer patients: A prospective study
PURPOSE: Deep inspiration breath‐hold (DIBH) is crucial in reducing the lung and cardiac dose for treatment of left‐sided breast cancer. We compared the stability and reproducibility of two DIBH techniques: Active Breathing Coordinator (ABC) and VisionRT (VRT). MATERIALS AND METHODS: We examined int...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
John Wiley and Sons Inc.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10161105/ https://www.ncbi.nlm.nih.gov/pubmed/36691339 http://dx.doi.org/10.1002/acm2.13906 |
_version_ | 1785037422169423872 |
---|---|
author | Parsons, David Joo, Mindy Iqbal, Zohaib Godley, Andrew Kim, Nathan Spangler, Ann Albuquerque, Kevin Sawant, Amit Zhao, Bo Gu, Xuejun Rahimi, Asal |
author_facet | Parsons, David Joo, Mindy Iqbal, Zohaib Godley, Andrew Kim, Nathan Spangler, Ann Albuquerque, Kevin Sawant, Amit Zhao, Bo Gu, Xuejun Rahimi, Asal |
author_sort | Parsons, David |
collection | PubMed |
description | PURPOSE: Deep inspiration breath‐hold (DIBH) is crucial in reducing the lung and cardiac dose for treatment of left‐sided breast cancer. We compared the stability and reproducibility of two DIBH techniques: Active Breathing Coordinator (ABC) and VisionRT (VRT). MATERIALS AND METHODS: We examined intra‐ and inter‐fraction positional variation of the left lung. Eight left‐sided breast cancer patients were monitored with electronic portal imaging during breath‐hold (BH) at every fraction. For each patient, half of the fractions were treated using ABC and the other half with VRT, with an equal amount starting with either ABC or VRT. The lung in each portal image was delineated, and the variation of its area was evaluated. Intrafraction stability was evaluated as the mean coefficient of variation (CV) of the lung area for the supraclavicular (SCV) and left lateral (LLat) field over the course of treatment. Reproducibility was the CV for the first image of each fraction. Daily session time and total imaging monitor units (MU) used in patient positioning were recorded. RESULTS: The mean intrafraction stability across all patients for the LLat field was 1.3 ± 0.7% and 1.5 ± 0.9% for VRT and ABC, respectively. Similarly, this was 1.5 ± 0.7% and 1.6 ± 0.8% for VRT and ABC, respectively, for the SCV field. The mean interfraction reproducibility for the LLat field was 11.0 ± 3.4% and 14.9 ± 6.0% for VRT and ABC, respectively. Similarly, this was 13.0 ± 2.5% and 14.8 ± 9% for VRT and ABC, respectively, for the SCV. No difference was observed in the number of verification images required for either technique. CONCLUSIONS: The stability and reproducibility were found to be comparable between ABC and VRT. ABC can have larger interfractional variation with less feedback to the treating therapist compared to VRT as shown in the increase in geometric misses at the matchline. |
format | Online Article Text |
id | pubmed-10161105 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | John Wiley and Sons Inc. |
record_format | MEDLINE/PubMed |
spelling | pubmed-101611052023-05-06 Stability and reproducibility comparisons between deep inspiration breath‐hold techniques for left‐sided breast cancer patients: A prospective study Parsons, David Joo, Mindy Iqbal, Zohaib Godley, Andrew Kim, Nathan Spangler, Ann Albuquerque, Kevin Sawant, Amit Zhao, Bo Gu, Xuejun Rahimi, Asal J Appl Clin Med Phys Radiation Oncology Physics PURPOSE: Deep inspiration breath‐hold (DIBH) is crucial in reducing the lung and cardiac dose for treatment of left‐sided breast cancer. We compared the stability and reproducibility of two DIBH techniques: Active Breathing Coordinator (ABC) and VisionRT (VRT). MATERIALS AND METHODS: We examined intra‐ and inter‐fraction positional variation of the left lung. Eight left‐sided breast cancer patients were monitored with electronic portal imaging during breath‐hold (BH) at every fraction. For each patient, half of the fractions were treated using ABC and the other half with VRT, with an equal amount starting with either ABC or VRT. The lung in each portal image was delineated, and the variation of its area was evaluated. Intrafraction stability was evaluated as the mean coefficient of variation (CV) of the lung area for the supraclavicular (SCV) and left lateral (LLat) field over the course of treatment. Reproducibility was the CV for the first image of each fraction. Daily session time and total imaging monitor units (MU) used in patient positioning were recorded. RESULTS: The mean intrafraction stability across all patients for the LLat field was 1.3 ± 0.7% and 1.5 ± 0.9% for VRT and ABC, respectively. Similarly, this was 1.5 ± 0.7% and 1.6 ± 0.8% for VRT and ABC, respectively, for the SCV field. The mean interfraction reproducibility for the LLat field was 11.0 ± 3.4% and 14.9 ± 6.0% for VRT and ABC, respectively. Similarly, this was 13.0 ± 2.5% and 14.8 ± 9% for VRT and ABC, respectively, for the SCV. No difference was observed in the number of verification images required for either technique. CONCLUSIONS: The stability and reproducibility were found to be comparable between ABC and VRT. ABC can have larger interfractional variation with less feedback to the treating therapist compared to VRT as shown in the increase in geometric misses at the matchline. John Wiley and Sons Inc. 2023-01-23 /pmc/articles/PMC10161105/ /pubmed/36691339 http://dx.doi.org/10.1002/acm2.13906 Text en © 2023 The Authors. Journal of Applied Clinical Medical Physics published by Wiley Periodicals, LLC on behalf of The American Association of Physicists in Medicine. https://creativecommons.org/licenses/by/4.0/This is an open access article under the terms of the http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) License, which permits use, distribution and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Radiation Oncology Physics Parsons, David Joo, Mindy Iqbal, Zohaib Godley, Andrew Kim, Nathan Spangler, Ann Albuquerque, Kevin Sawant, Amit Zhao, Bo Gu, Xuejun Rahimi, Asal Stability and reproducibility comparisons between deep inspiration breath‐hold techniques for left‐sided breast cancer patients: A prospective study |
title | Stability and reproducibility comparisons between deep inspiration breath‐hold techniques for left‐sided breast cancer patients: A prospective study |
title_full | Stability and reproducibility comparisons between deep inspiration breath‐hold techniques for left‐sided breast cancer patients: A prospective study |
title_fullStr | Stability and reproducibility comparisons between deep inspiration breath‐hold techniques for left‐sided breast cancer patients: A prospective study |
title_full_unstemmed | Stability and reproducibility comparisons between deep inspiration breath‐hold techniques for left‐sided breast cancer patients: A prospective study |
title_short | Stability and reproducibility comparisons between deep inspiration breath‐hold techniques for left‐sided breast cancer patients: A prospective study |
title_sort | stability and reproducibility comparisons between deep inspiration breath‐hold techniques for left‐sided breast cancer patients: a prospective study |
topic | Radiation Oncology Physics |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10161105/ https://www.ncbi.nlm.nih.gov/pubmed/36691339 http://dx.doi.org/10.1002/acm2.13906 |
work_keys_str_mv | AT parsonsdavid stabilityandreproducibilitycomparisonsbetweendeepinspirationbreathholdtechniquesforleftsidedbreastcancerpatientsaprospectivestudy AT joomindy stabilityandreproducibilitycomparisonsbetweendeepinspirationbreathholdtechniquesforleftsidedbreastcancerpatientsaprospectivestudy AT iqbalzohaib stabilityandreproducibilitycomparisonsbetweendeepinspirationbreathholdtechniquesforleftsidedbreastcancerpatientsaprospectivestudy AT godleyandrew stabilityandreproducibilitycomparisonsbetweendeepinspirationbreathholdtechniquesforleftsidedbreastcancerpatientsaprospectivestudy AT kimnathan stabilityandreproducibilitycomparisonsbetweendeepinspirationbreathholdtechniquesforleftsidedbreastcancerpatientsaprospectivestudy AT spanglerann stabilityandreproducibilitycomparisonsbetweendeepinspirationbreathholdtechniquesforleftsidedbreastcancerpatientsaprospectivestudy AT albuquerquekevin stabilityandreproducibilitycomparisonsbetweendeepinspirationbreathholdtechniquesforleftsidedbreastcancerpatientsaprospectivestudy AT sawantamit stabilityandreproducibilitycomparisonsbetweendeepinspirationbreathholdtechniquesforleftsidedbreastcancerpatientsaprospectivestudy AT zhaobo stabilityandreproducibilitycomparisonsbetweendeepinspirationbreathholdtechniquesforleftsidedbreastcancerpatientsaprospectivestudy AT guxuejun stabilityandreproducibilitycomparisonsbetweendeepinspirationbreathholdtechniquesforleftsidedbreastcancerpatientsaprospectivestudy AT rahimiasal stabilityandreproducibilitycomparisonsbetweendeepinspirationbreathholdtechniquesforleftsidedbreastcancerpatientsaprospectivestudy |