Cargando…
Mechanical study of the application of compression screw nails in the cross-inverted triangular pattern for internal fixation of femoral neck fractures
OBJECTIVE: To design a cross-inverted triangular pattern to insert compression screw nails for the treatment of femoral neck fractures and to compare the biomechanics of inserting compression screw nails in cross-inverted triangular patterns and inverted triangular patterns. METHODS: The reasonablen...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10161489/ https://www.ncbi.nlm.nih.gov/pubmed/37147608 http://dx.doi.org/10.1186/s12891-023-06297-x |
_version_ | 1785037505572110336 |
---|---|
author | Wang, Min Wang, Yunlong Zou, Fa Tan, Lin Wang, Yunjuan |
author_facet | Wang, Min Wang, Yunlong Zou, Fa Tan, Lin Wang, Yunjuan |
author_sort | Wang, Min |
collection | PubMed |
description | OBJECTIVE: To design a cross-inverted triangular pattern to insert compression screw nails for the treatment of femoral neck fractures and to compare the biomechanics of inserting compression screw nails in cross-inverted triangular patterns and inverted triangular patterns. METHODS: The reasonableness of the model is first analyzed using finite elements. A total of 6 adult human specimens were selected, of which 3 males and 3 females were divided into the A1, B1, and C1 groups and the A2, B2, and C2 groups by the random number table method. The A1 and A2 groups were made into subhead femoral neck fracture models, the B1 and B2 groups were made into trans-neck femoral neck fracture models, and the C1 and C2 groups were made into basal femoral neck fracture models. The right femur of each group had a compression screw nail inserted in the crossed-inverted triangular pattern, and the left femur of each group had a compression screw nail inserted in the inverted triangular pattern. The static compression test was performed by an electronic universal testing machine. The maximum load of the femoral neck and the load of 3.00 mm axial displacement of the femoral head were read according to the pressure-displacement curve drawn in the experiment. RESULTS: The finite element analysis showed that the cross-inverted triangular hollow threaded nail has better conductivity and more stable fixation than the inverted triangular hollow threaded nail. The maximum load of the femoral neck and the load of 3.00 mm axial displacement of the femoral head of the left femur were greater than those of the right femur in the A1, A2, B1, B2 and C2 groups, while the maximum load of the femoral neck and the load of 3.00 mm axial displacement of the femoral head of the left femur were smaller than those of the right femur in the C1 group. There was no statistically significant difference in the maximum load of the femoral neck or the load of 3.00 mm axial displacement of the femoral head between the A1 and A2 groups, the B1 and B2 groups, or the C1 and C2 groups (P > 0.05). After the K-S test, the maximum load of the femoral neck and the load of 3.00 mm axial displacement of the femoral head were normally distributed (P = 0.20), and the LSD-t test was conducted for the two load data; the difference was not statistically significant (P = 0.235). CONCLUSION: The effect of compression screw nails in the cross-inverted triangular pattern was the same in males and females, and stability was better in the fixation of subhead and trans-neck femoral neck fractures. However, its stability in fixation of basal femoral neck fracture is worse than that of the inverted triangular pattern. The cross-inverted triangular hollow threaded nail has better conductivity and more stable fixation than the inverted triangular hollow threaded nail. |
format | Online Article Text |
id | pubmed-10161489 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-101614892023-05-06 Mechanical study of the application of compression screw nails in the cross-inverted triangular pattern for internal fixation of femoral neck fractures Wang, Min Wang, Yunlong Zou, Fa Tan, Lin Wang, Yunjuan BMC Musculoskelet Disord Research OBJECTIVE: To design a cross-inverted triangular pattern to insert compression screw nails for the treatment of femoral neck fractures and to compare the biomechanics of inserting compression screw nails in cross-inverted triangular patterns and inverted triangular patterns. METHODS: The reasonableness of the model is first analyzed using finite elements. A total of 6 adult human specimens were selected, of which 3 males and 3 females were divided into the A1, B1, and C1 groups and the A2, B2, and C2 groups by the random number table method. The A1 and A2 groups were made into subhead femoral neck fracture models, the B1 and B2 groups were made into trans-neck femoral neck fracture models, and the C1 and C2 groups were made into basal femoral neck fracture models. The right femur of each group had a compression screw nail inserted in the crossed-inverted triangular pattern, and the left femur of each group had a compression screw nail inserted in the inverted triangular pattern. The static compression test was performed by an electronic universal testing machine. The maximum load of the femoral neck and the load of 3.00 mm axial displacement of the femoral head were read according to the pressure-displacement curve drawn in the experiment. RESULTS: The finite element analysis showed that the cross-inverted triangular hollow threaded nail has better conductivity and more stable fixation than the inverted triangular hollow threaded nail. The maximum load of the femoral neck and the load of 3.00 mm axial displacement of the femoral head of the left femur were greater than those of the right femur in the A1, A2, B1, B2 and C2 groups, while the maximum load of the femoral neck and the load of 3.00 mm axial displacement of the femoral head of the left femur were smaller than those of the right femur in the C1 group. There was no statistically significant difference in the maximum load of the femoral neck or the load of 3.00 mm axial displacement of the femoral head between the A1 and A2 groups, the B1 and B2 groups, or the C1 and C2 groups (P > 0.05). After the K-S test, the maximum load of the femoral neck and the load of 3.00 mm axial displacement of the femoral head were normally distributed (P = 0.20), and the LSD-t test was conducted for the two load data; the difference was not statistically significant (P = 0.235). CONCLUSION: The effect of compression screw nails in the cross-inverted triangular pattern was the same in males and females, and stability was better in the fixation of subhead and trans-neck femoral neck fractures. However, its stability in fixation of basal femoral neck fracture is worse than that of the inverted triangular pattern. The cross-inverted triangular hollow threaded nail has better conductivity and more stable fixation than the inverted triangular hollow threaded nail. BioMed Central 2023-05-05 /pmc/articles/PMC10161489/ /pubmed/37147608 http://dx.doi.org/10.1186/s12891-023-06297-x Text en © The Author(s) 2023, corrected publication 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Wang, Min Wang, Yunlong Zou, Fa Tan, Lin Wang, Yunjuan Mechanical study of the application of compression screw nails in the cross-inverted triangular pattern for internal fixation of femoral neck fractures |
title | Mechanical study of the application of compression screw nails in the cross-inverted triangular pattern for internal fixation of femoral neck fractures |
title_full | Mechanical study of the application of compression screw nails in the cross-inverted triangular pattern for internal fixation of femoral neck fractures |
title_fullStr | Mechanical study of the application of compression screw nails in the cross-inverted triangular pattern for internal fixation of femoral neck fractures |
title_full_unstemmed | Mechanical study of the application of compression screw nails in the cross-inverted triangular pattern for internal fixation of femoral neck fractures |
title_short | Mechanical study of the application of compression screw nails in the cross-inverted triangular pattern for internal fixation of femoral neck fractures |
title_sort | mechanical study of the application of compression screw nails in the cross-inverted triangular pattern for internal fixation of femoral neck fractures |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10161489/ https://www.ncbi.nlm.nih.gov/pubmed/37147608 http://dx.doi.org/10.1186/s12891-023-06297-x |
work_keys_str_mv | AT wangmin mechanicalstudyoftheapplicationofcompressionscrewnailsinthecrossinvertedtriangularpatternforinternalfixationoffemoralneckfractures AT wangyunlong mechanicalstudyoftheapplicationofcompressionscrewnailsinthecrossinvertedtriangularpatternforinternalfixationoffemoralneckfractures AT zoufa mechanicalstudyoftheapplicationofcompressionscrewnailsinthecrossinvertedtriangularpatternforinternalfixationoffemoralneckfractures AT tanlin mechanicalstudyoftheapplicationofcompressionscrewnailsinthecrossinvertedtriangularpatternforinternalfixationoffemoralneckfractures AT wangyunjuan mechanicalstudyoftheapplicationofcompressionscrewnailsinthecrossinvertedtriangularpatternforinternalfixationoffemoralneckfractures |