Cargando…
A new full-field XRF imaging station at Synchrotron Light Research Institute
A full-field X-ray fluorescence imaging (FXI) station was recently developed at beamline BL8 of Synchrotron Light Research Institute (SLRI), Thailand. An unfocused, synchrotron X-ray beam from the bending magnet with a size of 2 mm (vertical) × 13 mm (horizontal) and photon energy of 10 keV was empl...
Autores principales: | , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
International Union of Crystallography
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10161892/ https://www.ncbi.nlm.nih.gov/pubmed/37093013 http://dx.doi.org/10.1107/S1600577523002722 |
_version_ | 1785037590279225344 |
---|---|
author | Klysubun, Wantana Tarawarakarn, Pongjakr Thamsanong, Noppawath Mahakhod, Sompin Amonpattaratkit, Penphitcha Cholsuk, Chanakan |
author_facet | Klysubun, Wantana Tarawarakarn, Pongjakr Thamsanong, Noppawath Mahakhod, Sompin Amonpattaratkit, Penphitcha Cholsuk, Chanakan |
author_sort | Klysubun, Wantana |
collection | PubMed |
description | A full-field X-ray fluorescence imaging (FXI) station was recently developed at beamline BL8 of Synchrotron Light Research Institute (SLRI), Thailand. An unfocused, synchrotron X-ray beam from the bending magnet with a size of 2 mm (vertical) × 13 mm (horizontal) and photon energy of 10 keV was employed in the FXI experiments. A sample stage was tilted by 7.5° to enlarge the vertical beam size. X-ray fluorescence images were recorded by an energy-dispersive, 256 × 256 array, pn-type charge coupled device detector equipped with a polycapillary optics, providing a full-frame image size of 12.3 mm × 12.3 mm. The incident photon flux per pixel was 3 × 10(4) photons s(−1) (100 mA)(−1) and the experimental spatial resolution was 68 µm. Image processing was carried out offline using an in-house MATLAB program capable of elemental selection and inhomogeneity intensity correction. Elemental detection limits of FXI were found to decrease with increasing atomic number, i.e. 0.3 to 0.03 wt% for Z = 19 (K) to 30 (Zn). Compared with the BL6b microbeam imaging (µXI) station at SLRI with higher photon flux per pixel, 3 × 10(10) photons s(−1) (100 mA)(−1), a tenfold sample area can be obtained and 13 times higher peak-to-background (PKB) ratio at Zn K (α) measured with the same experimental time (8 h). Simultaneous measurement of FXI is more time-efficient against the long overhead times of µXI scanning over large pixel numbers, >65000. To demonstrate potential applications of the new FXI station, various types of samples were examined: dendritic limestone, ancient bronze and dried fish. Analyzed elemental images enabled us to identify areas rich in Mn on the limestone, Sn and Cu separation in the bronze, and Zn nutrition in the dried fish eye. |
format | Online Article Text |
id | pubmed-10161892 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | International Union of Crystallography |
record_format | MEDLINE/PubMed |
spelling | pubmed-101618922023-05-06 A new full-field XRF imaging station at Synchrotron Light Research Institute Klysubun, Wantana Tarawarakarn, Pongjakr Thamsanong, Noppawath Mahakhod, Sompin Amonpattaratkit, Penphitcha Cholsuk, Chanakan J Synchrotron Radiat Beamlines A full-field X-ray fluorescence imaging (FXI) station was recently developed at beamline BL8 of Synchrotron Light Research Institute (SLRI), Thailand. An unfocused, synchrotron X-ray beam from the bending magnet with a size of 2 mm (vertical) × 13 mm (horizontal) and photon energy of 10 keV was employed in the FXI experiments. A sample stage was tilted by 7.5° to enlarge the vertical beam size. X-ray fluorescence images were recorded by an energy-dispersive, 256 × 256 array, pn-type charge coupled device detector equipped with a polycapillary optics, providing a full-frame image size of 12.3 mm × 12.3 mm. The incident photon flux per pixel was 3 × 10(4) photons s(−1) (100 mA)(−1) and the experimental spatial resolution was 68 µm. Image processing was carried out offline using an in-house MATLAB program capable of elemental selection and inhomogeneity intensity correction. Elemental detection limits of FXI were found to decrease with increasing atomic number, i.e. 0.3 to 0.03 wt% for Z = 19 (K) to 30 (Zn). Compared with the BL6b microbeam imaging (µXI) station at SLRI with higher photon flux per pixel, 3 × 10(10) photons s(−1) (100 mA)(−1), a tenfold sample area can be obtained and 13 times higher peak-to-background (PKB) ratio at Zn K (α) measured with the same experimental time (8 h). Simultaneous measurement of FXI is more time-efficient against the long overhead times of µXI scanning over large pixel numbers, >65000. To demonstrate potential applications of the new FXI station, various types of samples were examined: dendritic limestone, ancient bronze and dried fish. Analyzed elemental images enabled us to identify areas rich in Mn on the limestone, Sn and Cu separation in the bronze, and Zn nutrition in the dried fish eye. International Union of Crystallography 2023-04-24 /pmc/articles/PMC10161892/ /pubmed/37093013 http://dx.doi.org/10.1107/S1600577523002722 Text en © Wantana Klysubun et al. 2023 https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution (CC-BY) Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited. |
spellingShingle | Beamlines Klysubun, Wantana Tarawarakarn, Pongjakr Thamsanong, Noppawath Mahakhod, Sompin Amonpattaratkit, Penphitcha Cholsuk, Chanakan A new full-field XRF imaging station at Synchrotron Light Research Institute |
title | A new full-field XRF imaging station at Synchrotron Light Research Institute |
title_full | A new full-field XRF imaging station at Synchrotron Light Research Institute |
title_fullStr | A new full-field XRF imaging station at Synchrotron Light Research Institute |
title_full_unstemmed | A new full-field XRF imaging station at Synchrotron Light Research Institute |
title_short | A new full-field XRF imaging station at Synchrotron Light Research Institute |
title_sort | new full-field xrf imaging station at synchrotron light research institute |
topic | Beamlines |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10161892/ https://www.ncbi.nlm.nih.gov/pubmed/37093013 http://dx.doi.org/10.1107/S1600577523002722 |
work_keys_str_mv | AT klysubunwantana anewfullfieldxrfimagingstationatsynchrotronlightresearchinstitute AT tarawarakarnpongjakr anewfullfieldxrfimagingstationatsynchrotronlightresearchinstitute AT thamsanongnoppawath anewfullfieldxrfimagingstationatsynchrotronlightresearchinstitute AT mahakhodsompin anewfullfieldxrfimagingstationatsynchrotronlightresearchinstitute AT amonpattaratkitpenphitcha anewfullfieldxrfimagingstationatsynchrotronlightresearchinstitute AT cholsukchanakan anewfullfieldxrfimagingstationatsynchrotronlightresearchinstitute AT klysubunwantana newfullfieldxrfimagingstationatsynchrotronlightresearchinstitute AT tarawarakarnpongjakr newfullfieldxrfimagingstationatsynchrotronlightresearchinstitute AT thamsanongnoppawath newfullfieldxrfimagingstationatsynchrotronlightresearchinstitute AT mahakhodsompin newfullfieldxrfimagingstationatsynchrotronlightresearchinstitute AT amonpattaratkitpenphitcha newfullfieldxrfimagingstationatsynchrotronlightresearchinstitute AT cholsukchanakan newfullfieldxrfimagingstationatsynchrotronlightresearchinstitute |