Cargando…

A new full-field XRF imaging station at Synchrotron Light Research Institute

A full-field X-ray fluorescence imaging (FXI) station was recently developed at beamline BL8 of Synchrotron Light Research Institute (SLRI), Thailand. An unfocused, synchrotron X-ray beam from the bending magnet with a size of 2 mm (vertical) × 13 mm (horizontal) and photon energy of 10 keV was empl...

Descripción completa

Detalles Bibliográficos
Autores principales: Klysubun, Wantana, Tarawarakarn, Pongjakr, Thamsanong, Noppawath, Mahakhod, Sompin, Amonpattaratkit, Penphitcha, Cholsuk, Chanakan
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Union of Crystallography 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10161892/
https://www.ncbi.nlm.nih.gov/pubmed/37093013
http://dx.doi.org/10.1107/S1600577523002722
_version_ 1785037590279225344
author Klysubun, Wantana
Tarawarakarn, Pongjakr
Thamsanong, Noppawath
Mahakhod, Sompin
Amonpattaratkit, Penphitcha
Cholsuk, Chanakan
author_facet Klysubun, Wantana
Tarawarakarn, Pongjakr
Thamsanong, Noppawath
Mahakhod, Sompin
Amonpattaratkit, Penphitcha
Cholsuk, Chanakan
author_sort Klysubun, Wantana
collection PubMed
description A full-field X-ray fluorescence imaging (FXI) station was recently developed at beamline BL8 of Synchrotron Light Research Institute (SLRI), Thailand. An unfocused, synchrotron X-ray beam from the bending magnet with a size of 2 mm (vertical) × 13 mm (horizontal) and photon energy of 10 keV was employed in the FXI experiments. A sample stage was tilted by 7.5° to enlarge the vertical beam size. X-ray fluorescence images were recorded by an energy-dispersive, 256 × 256 array, pn-type charge coupled device detector equipped with a polycapillary optics, providing a full-frame image size of 12.3 mm × 12.3 mm. The incident photon flux per pixel was 3 × 10(4) photons s(−1) (100 mA)(−1) and the experimental spatial resolution was 68 µm. Image processing was carried out offline using an in-house MATLAB program capable of elemental selection and inhomogeneity intensity correction. Elemental detection limits of FXI were found to decrease with increasing atomic number, i.e. 0.3 to 0.03 wt% for Z = 19 (K) to 30 (Zn). Compared with the BL6b microbeam imaging (µXI) station at SLRI with higher photon flux per pixel, 3 × 10(10) photons s(−1) (100 mA)(−1), a tenfold sample area can be obtained and 13 times higher peak-to-background (PKB) ratio at Zn K (α) measured with the same experimental time (8 h). Simultaneous measurement of FXI is more time-efficient against the long overhead times of µXI scanning over large pixel numbers, >65000. To demonstrate potential applications of the new FXI station, various types of samples were examined: dendritic limestone, ancient bronze and dried fish. Analyzed elemental images enabled us to identify areas rich in Mn on the limestone, Sn and Cu separation in the bronze, and Zn nutrition in the dried fish eye.
format Online
Article
Text
id pubmed-10161892
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher International Union of Crystallography
record_format MEDLINE/PubMed
spelling pubmed-101618922023-05-06 A new full-field XRF imaging station at Synchrotron Light Research Institute Klysubun, Wantana Tarawarakarn, Pongjakr Thamsanong, Noppawath Mahakhod, Sompin Amonpattaratkit, Penphitcha Cholsuk, Chanakan J Synchrotron Radiat Beamlines A full-field X-ray fluorescence imaging (FXI) station was recently developed at beamline BL8 of Synchrotron Light Research Institute (SLRI), Thailand. An unfocused, synchrotron X-ray beam from the bending magnet with a size of 2 mm (vertical) × 13 mm (horizontal) and photon energy of 10 keV was employed in the FXI experiments. A sample stage was tilted by 7.5° to enlarge the vertical beam size. X-ray fluorescence images were recorded by an energy-dispersive, 256 × 256 array, pn-type charge coupled device detector equipped with a polycapillary optics, providing a full-frame image size of 12.3 mm × 12.3 mm. The incident photon flux per pixel was 3 × 10(4) photons s(−1) (100 mA)(−1) and the experimental spatial resolution was 68 µm. Image processing was carried out offline using an in-house MATLAB program capable of elemental selection and inhomogeneity intensity correction. Elemental detection limits of FXI were found to decrease with increasing atomic number, i.e. 0.3 to 0.03 wt% for Z = 19 (K) to 30 (Zn). Compared with the BL6b microbeam imaging (µXI) station at SLRI with higher photon flux per pixel, 3 × 10(10) photons s(−1) (100 mA)(−1), a tenfold sample area can be obtained and 13 times higher peak-to-background (PKB) ratio at Zn K (α) measured with the same experimental time (8 h). Simultaneous measurement of FXI is more time-efficient against the long overhead times of µXI scanning over large pixel numbers, >65000. To demonstrate potential applications of the new FXI station, various types of samples were examined: dendritic limestone, ancient bronze and dried fish. Analyzed elemental images enabled us to identify areas rich in Mn on the limestone, Sn and Cu separation in the bronze, and Zn nutrition in the dried fish eye. International Union of Crystallography 2023-04-24 /pmc/articles/PMC10161892/ /pubmed/37093013 http://dx.doi.org/10.1107/S1600577523002722 Text en © Wantana Klysubun et al. 2023 https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution (CC-BY) Licence, which permits unrestricted use, distribution, and reproduction in any medium, provided the original authors and source are cited.
spellingShingle Beamlines
Klysubun, Wantana
Tarawarakarn, Pongjakr
Thamsanong, Noppawath
Mahakhod, Sompin
Amonpattaratkit, Penphitcha
Cholsuk, Chanakan
A new full-field XRF imaging station at Synchrotron Light Research Institute
title A new full-field XRF imaging station at Synchrotron Light Research Institute
title_full A new full-field XRF imaging station at Synchrotron Light Research Institute
title_fullStr A new full-field XRF imaging station at Synchrotron Light Research Institute
title_full_unstemmed A new full-field XRF imaging station at Synchrotron Light Research Institute
title_short A new full-field XRF imaging station at Synchrotron Light Research Institute
title_sort new full-field xrf imaging station at synchrotron light research institute
topic Beamlines
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10161892/
https://www.ncbi.nlm.nih.gov/pubmed/37093013
http://dx.doi.org/10.1107/S1600577523002722
work_keys_str_mv AT klysubunwantana anewfullfieldxrfimagingstationatsynchrotronlightresearchinstitute
AT tarawarakarnpongjakr anewfullfieldxrfimagingstationatsynchrotronlightresearchinstitute
AT thamsanongnoppawath anewfullfieldxrfimagingstationatsynchrotronlightresearchinstitute
AT mahakhodsompin anewfullfieldxrfimagingstationatsynchrotronlightresearchinstitute
AT amonpattaratkitpenphitcha anewfullfieldxrfimagingstationatsynchrotronlightresearchinstitute
AT cholsukchanakan anewfullfieldxrfimagingstationatsynchrotronlightresearchinstitute
AT klysubunwantana newfullfieldxrfimagingstationatsynchrotronlightresearchinstitute
AT tarawarakarnpongjakr newfullfieldxrfimagingstationatsynchrotronlightresearchinstitute
AT thamsanongnoppawath newfullfieldxrfimagingstationatsynchrotronlightresearchinstitute
AT mahakhodsompin newfullfieldxrfimagingstationatsynchrotronlightresearchinstitute
AT amonpattaratkitpenphitcha newfullfieldxrfimagingstationatsynchrotronlightresearchinstitute
AT cholsukchanakan newfullfieldxrfimagingstationatsynchrotronlightresearchinstitute