Cargando…
Influence of Denture Cleansers on the Retention Loss of Attachment Systems Retained Implant Overdenture
BACKGROUND: This study aimed to evaluate the effects of different denture cleansing solutions (DCSs) on the retention of Locator and Locator R-Tx attachment systems of implant retained overdentures (IRO). METHODS: Two part acrylic resin blocks were fabricated, upper part contained metal housing and...
Autores principales: | , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Hindawi
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10163970/ https://www.ncbi.nlm.nih.gov/pubmed/37159616 http://dx.doi.org/10.1155/2023/5077785 |
_version_ | 1785037991922630656 |
---|---|
author | AlRumaih, Hamad S. Albarrak, Alhanouf A. AlMedaires, Muneera Alsulaiman, Ahmed A. Baba, Nadim Z. Alshahrani, Faris A. Alqarawi, Firas K. Al-Dulaijan, Yousif A. Alzoubi, Fawaz Alhumaidan, Abdulkareem A. Gad, Mohammed M. |
author_facet | AlRumaih, Hamad S. Albarrak, Alhanouf A. AlMedaires, Muneera Alsulaiman, Ahmed A. Baba, Nadim Z. Alshahrani, Faris A. Alqarawi, Firas K. Al-Dulaijan, Yousif A. Alzoubi, Fawaz Alhumaidan, Abdulkareem A. Gad, Mohammed M. |
author_sort | AlRumaih, Hamad S. |
collection | PubMed |
description | BACKGROUND: This study aimed to evaluate the effects of different denture cleansing solutions (DCSs) on the retention of Locator and Locator R-Tx attachment systems of implant retained overdentures (IRO). METHODS: Two part acrylic resin blocks were fabricated, upper part contained metal housing and plastic inserts and lower part contained implant analogs and abutments. Eighty pink plastic inserts (40/attachment, 10/solution) were immersed in Corega, Fittydent, sodium hypochlorite, and water for a time simulating upto 1-year of clinical usage. Acrylic blocks were held on a universal testing machine for a pull-out test to record the dislodgement force. Measurements were conducted after 6 months (T1) and 12 months (T2). One-way ANOVA followed by Tukey's HSD test was used to analyze the results (α = 0.05). RESULTS: For both attachments, retention significantly decreased after immersion in different solutions at T2 (P < 0.001). Locator R-Tx attachment in NaOCl showed a significant decrease in retention compared with other solutions at T1. At T2, there was a significant decrease in retention for all DCS compared with water (P < 0.001). Locator R-TX showed higher retention values per solution compared to Locator attachment (P < 0.001). In terms of retention loss %, NaOCl recorded the highest (61.87%) loss, followed by Corega (55.54%) and Fittydent (43.13%), whereas water demonstrated the best retention (16.13%) in both groups. CONCLUSION: Locator R-TX has better retention with different DCS immersion. The loss of retention varied with different types of DCS and NaOCl recorded the highest retention loss. Therefore, denture cleanser selection must be guided by the type of IRO attachment. |
format | Online Article Text |
id | pubmed-10163970 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Hindawi |
record_format | MEDLINE/PubMed |
spelling | pubmed-101639702023-05-07 Influence of Denture Cleansers on the Retention Loss of Attachment Systems Retained Implant Overdenture AlRumaih, Hamad S. Albarrak, Alhanouf A. AlMedaires, Muneera Alsulaiman, Ahmed A. Baba, Nadim Z. Alshahrani, Faris A. Alqarawi, Firas K. Al-Dulaijan, Yousif A. Alzoubi, Fawaz Alhumaidan, Abdulkareem A. Gad, Mohammed M. Int J Biomater Research Article BACKGROUND: This study aimed to evaluate the effects of different denture cleansing solutions (DCSs) on the retention of Locator and Locator R-Tx attachment systems of implant retained overdentures (IRO). METHODS: Two part acrylic resin blocks were fabricated, upper part contained metal housing and plastic inserts and lower part contained implant analogs and abutments. Eighty pink plastic inserts (40/attachment, 10/solution) were immersed in Corega, Fittydent, sodium hypochlorite, and water for a time simulating upto 1-year of clinical usage. Acrylic blocks were held on a universal testing machine for a pull-out test to record the dislodgement force. Measurements were conducted after 6 months (T1) and 12 months (T2). One-way ANOVA followed by Tukey's HSD test was used to analyze the results (α = 0.05). RESULTS: For both attachments, retention significantly decreased after immersion in different solutions at T2 (P < 0.001). Locator R-Tx attachment in NaOCl showed a significant decrease in retention compared with other solutions at T1. At T2, there was a significant decrease in retention for all DCS compared with water (P < 0.001). Locator R-TX showed higher retention values per solution compared to Locator attachment (P < 0.001). In terms of retention loss %, NaOCl recorded the highest (61.87%) loss, followed by Corega (55.54%) and Fittydent (43.13%), whereas water demonstrated the best retention (16.13%) in both groups. CONCLUSION: Locator R-TX has better retention with different DCS immersion. The loss of retention varied with different types of DCS and NaOCl recorded the highest retention loss. Therefore, denture cleanser selection must be guided by the type of IRO attachment. Hindawi 2023-04-29 /pmc/articles/PMC10163970/ /pubmed/37159616 http://dx.doi.org/10.1155/2023/5077785 Text en Copyright © 2023 Hamad S. AlRumaih et al. https://creativecommons.org/licenses/by/4.0/This is an open access article distributed under the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
spellingShingle | Research Article AlRumaih, Hamad S. Albarrak, Alhanouf A. AlMedaires, Muneera Alsulaiman, Ahmed A. Baba, Nadim Z. Alshahrani, Faris A. Alqarawi, Firas K. Al-Dulaijan, Yousif A. Alzoubi, Fawaz Alhumaidan, Abdulkareem A. Gad, Mohammed M. Influence of Denture Cleansers on the Retention Loss of Attachment Systems Retained Implant Overdenture |
title | Influence of Denture Cleansers on the Retention Loss of Attachment Systems Retained Implant Overdenture |
title_full | Influence of Denture Cleansers on the Retention Loss of Attachment Systems Retained Implant Overdenture |
title_fullStr | Influence of Denture Cleansers on the Retention Loss of Attachment Systems Retained Implant Overdenture |
title_full_unstemmed | Influence of Denture Cleansers on the Retention Loss of Attachment Systems Retained Implant Overdenture |
title_short | Influence of Denture Cleansers on the Retention Loss of Attachment Systems Retained Implant Overdenture |
title_sort | influence of denture cleansers on the retention loss of attachment systems retained implant overdenture |
topic | Research Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10163970/ https://www.ncbi.nlm.nih.gov/pubmed/37159616 http://dx.doi.org/10.1155/2023/5077785 |
work_keys_str_mv | AT alrumaihhamads influenceofdenturecleansersontheretentionlossofattachmentsystemsretainedimplantoverdenture AT albarrakalhanoufa influenceofdenturecleansersontheretentionlossofattachmentsystemsretainedimplantoverdenture AT almedairesmuneera influenceofdenturecleansersontheretentionlossofattachmentsystemsretainedimplantoverdenture AT alsulaimanahmeda influenceofdenturecleansersontheretentionlossofattachmentsystemsretainedimplantoverdenture AT babanadimz influenceofdenturecleansersontheretentionlossofattachmentsystemsretainedimplantoverdenture AT alshahranifarisa influenceofdenturecleansersontheretentionlossofattachmentsystemsretainedimplantoverdenture AT alqarawifirask influenceofdenturecleansersontheretentionlossofattachmentsystemsretainedimplantoverdenture AT aldulaijanyousifa influenceofdenturecleansersontheretentionlossofattachmentsystemsretainedimplantoverdenture AT alzoubifawaz influenceofdenturecleansersontheretentionlossofattachmentsystemsretainedimplantoverdenture AT alhumaidanabdulkareema influenceofdenturecleansersontheretentionlossofattachmentsystemsretainedimplantoverdenture AT gadmohammedm influenceofdenturecleansersontheretentionlossofattachmentsystemsretainedimplantoverdenture |