Cargando…
Corneal Higher-Order Aberrations Measurements: Precision of SD-OCT/Placido Topography and Comparison with a Scheimpflug/Placido Topography in Eyes After Small-Incision Lenticule Extraction
INTRODUCTION: The aim of this study was to evaluate the measurements of corneal higher-order aberrations (HOAs) obtained by a new anterior segment optical coherence tomography (OCT) technique combined with a Placido topographer (the MS-39 device) in eyes with prior small-incision lenticule extractio...
Autores principales: | , , , , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Healthcare
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10164219/ https://www.ncbi.nlm.nih.gov/pubmed/36862309 http://dx.doi.org/10.1007/s40123-023-00693-1 |
_version_ | 1785038024877277184 |
---|---|
author | Ning, Rui Huang, Xiaomin Jin, Yili Lei, Chak Seng Ma, Xindi Xu, Shuoyu Xiahou, Jinxuan Savini, Giacomo Schiano-Lomoriello, Domenico Wang, Xiaoying Zhou, Xingtao Huang, Jinhai |
author_facet | Ning, Rui Huang, Xiaomin Jin, Yili Lei, Chak Seng Ma, Xindi Xu, Shuoyu Xiahou, Jinxuan Savini, Giacomo Schiano-Lomoriello, Domenico Wang, Xiaoying Zhou, Xingtao Huang, Jinhai |
author_sort | Ning, Rui |
collection | PubMed |
description | INTRODUCTION: The aim of this study was to evaluate the measurements of corneal higher-order aberrations (HOAs) obtained by a new anterior segment optical coherence tomography (OCT) technique combined with a Placido topographer (the MS-39 device) in eyes with prior small-incision lenticule extraction (SMILE) and compare them to the measurements obtained by a Scheimpflug camera combined with a Placido topographer (the Sirius device). METHODS: A total of 56 eyes (56 patients) were included in this prospective study. Corneal aberrations were analyzed for the anterior, posterior, and total cornea surfaces. Within-subject standard deviation (S(w)), test–retest repeatability (TRT), and intraclass correlation coefficient (ICC) were used to assess the intraobserver repeatability and interobserver reproducibility. The differences were evaluated by paired t-test. Bland–Altman plots and 95% limits of agreement (95% LoA) were used to evaluate the agreement. RESULTS: High repeatability was observed for anterior and total corneal parameters, with S(w) value < 0.07, TRT ≤ 0.16, and ICCs > 0.893, but not trefoil. For the posterior corneal parameters, ICCs varied from 0.088 to 0.966. Regarding interobserver reproducibility, all S(w) values were ≤ 0.04 and TRT ≤ 0.11. ICCs ranged from 0.846 to 0.989, from 0.432 to 0.972, and from 0.798 to 0.985 for the anterior, total, and posterior corneal aberrations parameters, respectively. The mean difference in all aberrations was ≤ 0.05 μm. All parameters showed a narrow 95% LoA. CONCLUSION: The MS-39 device achieved high precision in both anterior and total corneal measurements; the precision of posterior corneal higher-order RMS, astigmatism II, coma, and trefoil was lower. The two technologies used by the MS-39 and Sirius devices can be used interchangeably for measuring corneal HOAs after SMILE. |
format | Online Article Text |
id | pubmed-10164219 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Springer Healthcare |
record_format | MEDLINE/PubMed |
spelling | pubmed-101642192023-05-08 Corneal Higher-Order Aberrations Measurements: Precision of SD-OCT/Placido Topography and Comparison with a Scheimpflug/Placido Topography in Eyes After Small-Incision Lenticule Extraction Ning, Rui Huang, Xiaomin Jin, Yili Lei, Chak Seng Ma, Xindi Xu, Shuoyu Xiahou, Jinxuan Savini, Giacomo Schiano-Lomoriello, Domenico Wang, Xiaoying Zhou, Xingtao Huang, Jinhai Ophthalmol Ther Original Research INTRODUCTION: The aim of this study was to evaluate the measurements of corneal higher-order aberrations (HOAs) obtained by a new anterior segment optical coherence tomography (OCT) technique combined with a Placido topographer (the MS-39 device) in eyes with prior small-incision lenticule extraction (SMILE) and compare them to the measurements obtained by a Scheimpflug camera combined with a Placido topographer (the Sirius device). METHODS: A total of 56 eyes (56 patients) were included in this prospective study. Corneal aberrations were analyzed for the anterior, posterior, and total cornea surfaces. Within-subject standard deviation (S(w)), test–retest repeatability (TRT), and intraclass correlation coefficient (ICC) were used to assess the intraobserver repeatability and interobserver reproducibility. The differences were evaluated by paired t-test. Bland–Altman plots and 95% limits of agreement (95% LoA) were used to evaluate the agreement. RESULTS: High repeatability was observed for anterior and total corneal parameters, with S(w) value < 0.07, TRT ≤ 0.16, and ICCs > 0.893, but not trefoil. For the posterior corneal parameters, ICCs varied from 0.088 to 0.966. Regarding interobserver reproducibility, all S(w) values were ≤ 0.04 and TRT ≤ 0.11. ICCs ranged from 0.846 to 0.989, from 0.432 to 0.972, and from 0.798 to 0.985 for the anterior, total, and posterior corneal aberrations parameters, respectively. The mean difference in all aberrations was ≤ 0.05 μm. All parameters showed a narrow 95% LoA. CONCLUSION: The MS-39 device achieved high precision in both anterior and total corneal measurements; the precision of posterior corneal higher-order RMS, astigmatism II, coma, and trefoil was lower. The two technologies used by the MS-39 and Sirius devices can be used interchangeably for measuring corneal HOAs after SMILE. Springer Healthcare 2023-03-02 2023-06 /pmc/articles/PMC10164219/ /pubmed/36862309 http://dx.doi.org/10.1007/s40123-023-00693-1 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by-nc/4.0/Open AccessThis article is licensed under a Creative Commons Attribution-NonCommercial 4.0 International License, which permits any non-commercial use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by-nc/4.0/ (https://creativecommons.org/licenses/by-nc/4.0/) . |
spellingShingle | Original Research Ning, Rui Huang, Xiaomin Jin, Yili Lei, Chak Seng Ma, Xindi Xu, Shuoyu Xiahou, Jinxuan Savini, Giacomo Schiano-Lomoriello, Domenico Wang, Xiaoying Zhou, Xingtao Huang, Jinhai Corneal Higher-Order Aberrations Measurements: Precision of SD-OCT/Placido Topography and Comparison with a Scheimpflug/Placido Topography in Eyes After Small-Incision Lenticule Extraction |
title | Corneal Higher-Order Aberrations Measurements: Precision of SD-OCT/Placido Topography and Comparison with a Scheimpflug/Placido Topography in Eyes After Small-Incision Lenticule Extraction |
title_full | Corneal Higher-Order Aberrations Measurements: Precision of SD-OCT/Placido Topography and Comparison with a Scheimpflug/Placido Topography in Eyes After Small-Incision Lenticule Extraction |
title_fullStr | Corneal Higher-Order Aberrations Measurements: Precision of SD-OCT/Placido Topography and Comparison with a Scheimpflug/Placido Topography in Eyes After Small-Incision Lenticule Extraction |
title_full_unstemmed | Corneal Higher-Order Aberrations Measurements: Precision of SD-OCT/Placido Topography and Comparison with a Scheimpflug/Placido Topography in Eyes After Small-Incision Lenticule Extraction |
title_short | Corneal Higher-Order Aberrations Measurements: Precision of SD-OCT/Placido Topography and Comparison with a Scheimpflug/Placido Topography in Eyes After Small-Incision Lenticule Extraction |
title_sort | corneal higher-order aberrations measurements: precision of sd-oct/placido topography and comparison with a scheimpflug/placido topography in eyes after small-incision lenticule extraction |
topic | Original Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10164219/ https://www.ncbi.nlm.nih.gov/pubmed/36862309 http://dx.doi.org/10.1007/s40123-023-00693-1 |
work_keys_str_mv | AT ningrui cornealhigherorderaberrationsmeasurementsprecisionofsdoctplacidotopographyandcomparisonwithascheimpflugplacidotopographyineyesaftersmallincisionlenticuleextraction AT huangxiaomin cornealhigherorderaberrationsmeasurementsprecisionofsdoctplacidotopographyandcomparisonwithascheimpflugplacidotopographyineyesaftersmallincisionlenticuleextraction AT jinyili cornealhigherorderaberrationsmeasurementsprecisionofsdoctplacidotopographyandcomparisonwithascheimpflugplacidotopographyineyesaftersmallincisionlenticuleextraction AT leichakseng cornealhigherorderaberrationsmeasurementsprecisionofsdoctplacidotopographyandcomparisonwithascheimpflugplacidotopographyineyesaftersmallincisionlenticuleextraction AT maxindi cornealhigherorderaberrationsmeasurementsprecisionofsdoctplacidotopographyandcomparisonwithascheimpflugplacidotopographyineyesaftersmallincisionlenticuleextraction AT xushuoyu cornealhigherorderaberrationsmeasurementsprecisionofsdoctplacidotopographyandcomparisonwithascheimpflugplacidotopographyineyesaftersmallincisionlenticuleextraction AT xiahoujinxuan cornealhigherorderaberrationsmeasurementsprecisionofsdoctplacidotopographyandcomparisonwithascheimpflugplacidotopographyineyesaftersmallincisionlenticuleextraction AT savinigiacomo cornealhigherorderaberrationsmeasurementsprecisionofsdoctplacidotopographyandcomparisonwithascheimpflugplacidotopographyineyesaftersmallincisionlenticuleextraction AT schianolomoriellodomenico cornealhigherorderaberrationsmeasurementsprecisionofsdoctplacidotopographyandcomparisonwithascheimpflugplacidotopographyineyesaftersmallincisionlenticuleextraction AT wangxiaoying cornealhigherorderaberrationsmeasurementsprecisionofsdoctplacidotopographyandcomparisonwithascheimpflugplacidotopographyineyesaftersmallincisionlenticuleextraction AT zhouxingtao cornealhigherorderaberrationsmeasurementsprecisionofsdoctplacidotopographyandcomparisonwithascheimpflugplacidotopographyineyesaftersmallincisionlenticuleextraction AT huangjinhai cornealhigherorderaberrationsmeasurementsprecisionofsdoctplacidotopographyandcomparisonwithascheimpflugplacidotopographyineyesaftersmallincisionlenticuleextraction |