Cargando…
Optimizing the tip position of a peripherally inserted central venous catheter under a multidisciplinary team approach in a patient with mirror-image dextrocardia: a case report
Peripherally inserted central venous catheters (PICCs) are widely used in cardiology because they are convenient, effective, and safe. However, PICC implantation in patients with mirror-image dextrocardia who have thoracic tumors has not yet been reported. In this case report, we describe a 46-year-...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
SAGE Publications
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10164255/ https://www.ncbi.nlm.nih.gov/pubmed/37143333 http://dx.doi.org/10.1177/03000605231169432 |
_version_ | 1785038033241767936 |
---|---|
author | Zhu, Xiaoju He, Juan Fu, Ming Liu, Chunhua Peng, Na |
author_facet | Zhu, Xiaoju He, Juan Fu, Ming Liu, Chunhua Peng, Na |
author_sort | Zhu, Xiaoju |
collection | PubMed |
description | Peripherally inserted central venous catheters (PICCs) are widely used in cardiology because they are convenient, effective, and safe. However, PICC implantation in patients with mirror-image dextrocardia who have thoracic tumors has not yet been reported. In this case report, we describe a 46-year-old patient with lung cancer who had a thoracic inclination and left pulmonary artery compression of the superior vena cava. PICC implantation under B-ultrasound guidance was planned. Because of the anatomical differences caused by mirror-image dextrocardia, we investigated the optimal position and measurement method for the tip of the PICC according to the compression site of the vascular lumen through a multidisciplinary team approach. Electrocardiography-assisted tip positioning combined with postoperative chest X-ray positioning was performed for accurate positioning. |
format | Online Article Text |
id | pubmed-10164255 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | SAGE Publications |
record_format | MEDLINE/PubMed |
spelling | pubmed-101642552023-05-08 Optimizing the tip position of a peripherally inserted central venous catheter under a multidisciplinary team approach in a patient with mirror-image dextrocardia: a case report Zhu, Xiaoju He, Juan Fu, Ming Liu, Chunhua Peng, Na J Int Med Res Case Reports Peripherally inserted central venous catheters (PICCs) are widely used in cardiology because they are convenient, effective, and safe. However, PICC implantation in patients with mirror-image dextrocardia who have thoracic tumors has not yet been reported. In this case report, we describe a 46-year-old patient with lung cancer who had a thoracic inclination and left pulmonary artery compression of the superior vena cava. PICC implantation under B-ultrasound guidance was planned. Because of the anatomical differences caused by mirror-image dextrocardia, we investigated the optimal position and measurement method for the tip of the PICC according to the compression site of the vascular lumen through a multidisciplinary team approach. Electrocardiography-assisted tip positioning combined with postoperative chest X-ray positioning was performed for accurate positioning. SAGE Publications 2023-05-04 /pmc/articles/PMC10164255/ /pubmed/37143333 http://dx.doi.org/10.1177/03000605231169432 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by-nc/4.0/Creative Commons Non Commercial CC BY-NC: This article is distributed under the terms of the Creative Commons Attribution-NonCommercial 4.0 License (https://creativecommons.org/licenses/by-nc/4.0/) which permits non-commercial use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access pages (https://us.sagepub.com/en-us/nam/open-access-at-sage). |
spellingShingle | Case Reports Zhu, Xiaoju He, Juan Fu, Ming Liu, Chunhua Peng, Na Optimizing the tip position of a peripherally inserted central venous catheter under a multidisciplinary team approach in a patient with mirror-image dextrocardia: a case report |
title | Optimizing the tip position of a peripherally inserted central venous catheter under a multidisciplinary team approach in a patient with mirror-image dextrocardia: a case report |
title_full | Optimizing the tip position of a peripherally inserted central venous catheter under a multidisciplinary team approach in a patient with mirror-image dextrocardia: a case report |
title_fullStr | Optimizing the tip position of a peripherally inserted central venous catheter under a multidisciplinary team approach in a patient with mirror-image dextrocardia: a case report |
title_full_unstemmed | Optimizing the tip position of a peripherally inserted central venous catheter under a multidisciplinary team approach in a patient with mirror-image dextrocardia: a case report |
title_short | Optimizing the tip position of a peripherally inserted central venous catheter under a multidisciplinary team approach in a patient with mirror-image dextrocardia: a case report |
title_sort | optimizing the tip position of a peripherally inserted central venous catheter under a multidisciplinary team approach in a patient with mirror-image dextrocardia: a case report |
topic | Case Reports |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10164255/ https://www.ncbi.nlm.nih.gov/pubmed/37143333 http://dx.doi.org/10.1177/03000605231169432 |
work_keys_str_mv | AT zhuxiaoju optimizingthetippositionofaperipherallyinsertedcentralvenouscatheterunderamultidisciplinaryteamapproachinapatientwithmirrorimagedextrocardiaacasereport AT hejuan optimizingthetippositionofaperipherallyinsertedcentralvenouscatheterunderamultidisciplinaryteamapproachinapatientwithmirrorimagedextrocardiaacasereport AT fuming optimizingthetippositionofaperipherallyinsertedcentralvenouscatheterunderamultidisciplinaryteamapproachinapatientwithmirrorimagedextrocardiaacasereport AT liuchunhua optimizingthetippositionofaperipherallyinsertedcentralvenouscatheterunderamultidisciplinaryteamapproachinapatientwithmirrorimagedextrocardiaacasereport AT pengna optimizingthetippositionofaperipherallyinsertedcentralvenouscatheterunderamultidisciplinaryteamapproachinapatientwithmirrorimagedextrocardiaacasereport |