Cargando…

Pooled RNA-extraction-free testing of saliva for the detection of SARS-CoV-2

The key to limiting SARS-CoV-2 spread is to identify virus-infected individuals (both symptomatic and asymptomatic) and isolate them from the general population. Hence, routine weekly testing for SARS-CoV-2 in all asymptomatic (capturing both infected and non-infected) individuals is considered crit...

Descripción completa

Detalles Bibliográficos
Autores principales: Allicock, Orchid M., Yolda-Carr, Devyn, Todd, John A., Wyllie, Anne L.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10165292/
https://www.ncbi.nlm.nih.gov/pubmed/37156888
http://dx.doi.org/10.1038/s41598-023-34662-2
_version_ 1785038238168121344
author Allicock, Orchid M.
Yolda-Carr, Devyn
Todd, John A.
Wyllie, Anne L.
author_facet Allicock, Orchid M.
Yolda-Carr, Devyn
Todd, John A.
Wyllie, Anne L.
author_sort Allicock, Orchid M.
collection PubMed
description The key to limiting SARS-CoV-2 spread is to identify virus-infected individuals (both symptomatic and asymptomatic) and isolate them from the general population. Hence, routine weekly testing for SARS-CoV-2 in all asymptomatic (capturing both infected and non-infected) individuals is considered critical in situations where a large number of individuals co-congregate such as schools, prisons, aged care facilities and industrial workplaces. Such testing is hampered by operational issues such as cost, test availability, access to healthcare workers and throughput. We developed the SalivaDirect RT-qPCR assay to increase access to SARS-CoV-2 testing via a low-cost, streamlined protocol using self-collected saliva. To expand the single sample testing protocol, we explored multiple extraction-free pooled saliva testing workflows prior to testing with the SalivaDirect RT-qPCR assay. A pool size of five, with or without heat inactivation at 65 °C for 15 min prior to testing resulted in a positive agreement of 98% and 89%, respectively, and an increased Ct value shift of 1.37 and 1.99 as compared to individual testing of the positive clinical saliva specimens. Applying this shift in Ct value to 316 individual, sequentially collected, SARS-CoV-2 positive saliva specimen results reported from six clinical laboratories using the original SalivaDirect assay, 100% of the samples would have been detected (Ct value < 45) had they been tested in the 1:5 pool strategy. The availability of multiple pooled testing workflows for laboratories can increase test turnaround time, permitting results in a more actionable time frame while minimizing testing costs and changes to laboratory operational flow.
format Online
Article
Text
id pubmed-10165292
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-101652922023-05-09 Pooled RNA-extraction-free testing of saliva for the detection of SARS-CoV-2 Allicock, Orchid M. Yolda-Carr, Devyn Todd, John A. Wyllie, Anne L. Sci Rep Article The key to limiting SARS-CoV-2 spread is to identify virus-infected individuals (both symptomatic and asymptomatic) and isolate them from the general population. Hence, routine weekly testing for SARS-CoV-2 in all asymptomatic (capturing both infected and non-infected) individuals is considered critical in situations where a large number of individuals co-congregate such as schools, prisons, aged care facilities and industrial workplaces. Such testing is hampered by operational issues such as cost, test availability, access to healthcare workers and throughput. We developed the SalivaDirect RT-qPCR assay to increase access to SARS-CoV-2 testing via a low-cost, streamlined protocol using self-collected saliva. To expand the single sample testing protocol, we explored multiple extraction-free pooled saliva testing workflows prior to testing with the SalivaDirect RT-qPCR assay. A pool size of five, with or without heat inactivation at 65 °C for 15 min prior to testing resulted in a positive agreement of 98% and 89%, respectively, and an increased Ct value shift of 1.37 and 1.99 as compared to individual testing of the positive clinical saliva specimens. Applying this shift in Ct value to 316 individual, sequentially collected, SARS-CoV-2 positive saliva specimen results reported from six clinical laboratories using the original SalivaDirect assay, 100% of the samples would have been detected (Ct value < 45) had they been tested in the 1:5 pool strategy. The availability of multiple pooled testing workflows for laboratories can increase test turnaround time, permitting results in a more actionable time frame while minimizing testing costs and changes to laboratory operational flow. Nature Publishing Group UK 2023-05-08 /pmc/articles/PMC10165292/ /pubmed/37156888 http://dx.doi.org/10.1038/s41598-023-34662-2 Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Allicock, Orchid M.
Yolda-Carr, Devyn
Todd, John A.
Wyllie, Anne L.
Pooled RNA-extraction-free testing of saliva for the detection of SARS-CoV-2
title Pooled RNA-extraction-free testing of saliva for the detection of SARS-CoV-2
title_full Pooled RNA-extraction-free testing of saliva for the detection of SARS-CoV-2
title_fullStr Pooled RNA-extraction-free testing of saliva for the detection of SARS-CoV-2
title_full_unstemmed Pooled RNA-extraction-free testing of saliva for the detection of SARS-CoV-2
title_short Pooled RNA-extraction-free testing of saliva for the detection of SARS-CoV-2
title_sort pooled rna-extraction-free testing of saliva for the detection of sars-cov-2
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10165292/
https://www.ncbi.nlm.nih.gov/pubmed/37156888
http://dx.doi.org/10.1038/s41598-023-34662-2
work_keys_str_mv AT allicockorchidm pooledrnaextractionfreetestingofsalivaforthedetectionofsarscov2
AT yoldacarrdevyn pooledrnaextractionfreetestingofsalivaforthedetectionofsarscov2
AT toddjohna pooledrnaextractionfreetestingofsalivaforthedetectionofsarscov2
AT wyllieannel pooledrnaextractionfreetestingofsalivaforthedetectionofsarscov2