Predicting hypercapnia and hypoxia by the ventilator's built-in software in children on long-term non-invasive ventilation: A pilot study

INTRODUCTION: Follow-up of children on long-term non-invasive ventilation (NIV) could be improved by telemonitoring, using the ventilator's built-in software (BIS) parameters as alternative for in-hospital sleep studies to reduce costs, enhance patient independence and contribute to early detec...

Descripción completa

Detalles Bibliográficos
Autores principales: Mentens, Xante, Vanhees, Janne, Paulussen, Jolien, Installé, Sophie, Van Ostaeyen, Anse, Ides, Kris, Jouret, Nathalie, Van Hoorenbeeck, Kim, Verhulst, Stijn
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10166201/
https://www.ncbi.nlm.nih.gov/pubmed/37168806
http://dx.doi.org/10.3389/fped.2023.1158396
Descripción
Sumario:INTRODUCTION: Follow-up of children on long-term non-invasive ventilation (NIV) could be improved by telemonitoring, using the ventilator's built-in software (BIS) parameters as alternative for in-hospital sleep studies to reduce costs, enhance patient independence and contribute to early detection of infections. This pilot study investigated whether analysis of BIS parameters can predict abnormal nocturnal transcutaneous CO2 (TcCO2) and saturation (SpO2) measurements in children on long-term NIV. METHODS: Children on long-term NIV in follow-up at the Antwerp University Hospital were retrospectively included. Nocturnal TcCO2 and SpO2 measurements were collected together with BIS parameters at three different time points: the night of the sleep study (BIS(1)), mean values from 48 h (BIS(2)) and 72 h (BIS(3)) before the sleep study. Predictions were calculated for following outcome measures: % recording time TcCO2 > 46.9 mmHg (%RT TcCO2; abnormal if ≥2%), recording time SpO2 < 93% (RT SpO2; abnormal if >1 h), abnormal TcCO2 or SpO2, mean TcCO2, mean SpO2. RESULTS: 69 patients were included. %RT TcCO2 was separately predicted by reached tidal volume(2) [OR 0.97 (0.93; 1.00); p = 0.051; AUC = 30%] and reached IPAP(1) [OR 1.05 (1.00; 1.10); p = 0.050; AUC = 66%]. Leak(1) predicted RT SpO2 [OR 1.21 (1.02; 1.43); p = 0.025; AUC = 84%]. Mean TcCO2 correlated with reached tidal volume(2) (R(2) 0.10, p = 0.033). DISCUSSION: Certain BIS parameters can predict nocturnal hypercapnia and desaturation in children on long-term NIV. Future studies with larger sample sizes are warranted to further investigate the predictive value of the identified BIS parameters.