Cargando…
The value of DCE- MRI of the breast as a diagnostic tool in assessing amorphous calcifications in screening mammography
PURPOSE: To evaluate the diagnostic performance of dynamic contrast-enhanced magnetic resonance imaging in differentiating benign and malignant amorphous calcifications. METHODS: This study included 193 female patients with 197 suspicious amorphous calcifications detected on screening mammography. T...
Autores principales: | , , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Frontiers Media S.A.
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10166994/ https://www.ncbi.nlm.nih.gov/pubmed/37182168 http://dx.doi.org/10.3389/fonc.2023.1151500 |
_version_ | 1785038566847414272 |
---|---|
author | Wang, Siqi Wang, Hui Li, Yang Lou, Jianjuan Zou, Qigui Jiang, Yanni Wu, Feiyun Tang, Yuxia Wang, Shouju |
author_facet | Wang, Siqi Wang, Hui Li, Yang Lou, Jianjuan Zou, Qigui Jiang, Yanni Wu, Feiyun Tang, Yuxia Wang, Shouju |
author_sort | Wang, Siqi |
collection | PubMed |
description | PURPOSE: To evaluate the diagnostic performance of dynamic contrast-enhanced magnetic resonance imaging in differentiating benign and malignant amorphous calcifications. METHODS: This study included 193 female patients with 197 suspicious amorphous calcifications detected on screening mammography. The patients’ demographics, clinical follow-up, imaging, and pathology outcomes were reviewed, and sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of DCE-MRI were calculated. RESULTS: Of 197 lesions (193 patients) included in the study, 50 (25.4%) were histologically proved to be malignant. DCE-MRI based on breast imaging report and diagnosis system (BI-RADS) had a sensitivity of 94.4%, specificity of 85.7%, PPV of 69.1%, and NPV of 97.7% for the detection of malignant amorphous calcifications. Notably, diagnosis solely based on the presence or absence of DCE-MRI enhancement showed the same sensitivity but significantly decreased specificity (44.8%, p < 0.001) and PPV (44.8%, p < 0.001). In patients with a minimal or mild degree of background parenchymal enhancement (BPE), the sensitivity, specificity, PPV, and NPV increased to 100%, 90.6%, 78.6%, and 100%, respectively. However, in patients with a moderate degree of BPE, MRI resulted in three false negatives of ductal carcinoma in situ (DCIS). Overall, the addition of DCE-MRI detected all invasive lesions and could decrease unnecessary biopsy by 65.5%. CONCLUSION: DCE-MRI based on BI-RADS has the potential to improve the diagnosis of suspicious amorphous calcifications and avoid unnecessary biopsy, especially for those with low-degree BPE. |
format | Online Article Text |
id | pubmed-10166994 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Frontiers Media S.A. |
record_format | MEDLINE/PubMed |
spelling | pubmed-101669942023-05-10 The value of DCE- MRI of the breast as a diagnostic tool in assessing amorphous calcifications in screening mammography Wang, Siqi Wang, Hui Li, Yang Lou, Jianjuan Zou, Qigui Jiang, Yanni Wu, Feiyun Tang, Yuxia Wang, Shouju Front Oncol Oncology PURPOSE: To evaluate the diagnostic performance of dynamic contrast-enhanced magnetic resonance imaging in differentiating benign and malignant amorphous calcifications. METHODS: This study included 193 female patients with 197 suspicious amorphous calcifications detected on screening mammography. The patients’ demographics, clinical follow-up, imaging, and pathology outcomes were reviewed, and sensitivity, specificity, positive predictive value (PPV), and negative predictive value (NPV) of DCE-MRI were calculated. RESULTS: Of 197 lesions (193 patients) included in the study, 50 (25.4%) were histologically proved to be malignant. DCE-MRI based on breast imaging report and diagnosis system (BI-RADS) had a sensitivity of 94.4%, specificity of 85.7%, PPV of 69.1%, and NPV of 97.7% for the detection of malignant amorphous calcifications. Notably, diagnosis solely based on the presence or absence of DCE-MRI enhancement showed the same sensitivity but significantly decreased specificity (44.8%, p < 0.001) and PPV (44.8%, p < 0.001). In patients with a minimal or mild degree of background parenchymal enhancement (BPE), the sensitivity, specificity, PPV, and NPV increased to 100%, 90.6%, 78.6%, and 100%, respectively. However, in patients with a moderate degree of BPE, MRI resulted in three false negatives of ductal carcinoma in situ (DCIS). Overall, the addition of DCE-MRI detected all invasive lesions and could decrease unnecessary biopsy by 65.5%. CONCLUSION: DCE-MRI based on BI-RADS has the potential to improve the diagnosis of suspicious amorphous calcifications and avoid unnecessary biopsy, especially for those with low-degree BPE. Frontiers Media S.A. 2023-04-25 /pmc/articles/PMC10166994/ /pubmed/37182168 http://dx.doi.org/10.3389/fonc.2023.1151500 Text en Copyright © 2023 Wang, Wang, Li, Lou, Zou, Jiang, Wu, Tang and Wang https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms. |
spellingShingle | Oncology Wang, Siqi Wang, Hui Li, Yang Lou, Jianjuan Zou, Qigui Jiang, Yanni Wu, Feiyun Tang, Yuxia Wang, Shouju The value of DCE- MRI of the breast as a diagnostic tool in assessing amorphous calcifications in screening mammography |
title | The value of DCE- MRI of the breast as a diagnostic tool in assessing amorphous calcifications in screening mammography |
title_full | The value of DCE- MRI of the breast as a diagnostic tool in assessing amorphous calcifications in screening mammography |
title_fullStr | The value of DCE- MRI of the breast as a diagnostic tool in assessing amorphous calcifications in screening mammography |
title_full_unstemmed | The value of DCE- MRI of the breast as a diagnostic tool in assessing amorphous calcifications in screening mammography |
title_short | The value of DCE- MRI of the breast as a diagnostic tool in assessing amorphous calcifications in screening mammography |
title_sort | value of dce- mri of the breast as a diagnostic tool in assessing amorphous calcifications in screening mammography |
topic | Oncology |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10166994/ https://www.ncbi.nlm.nih.gov/pubmed/37182168 http://dx.doi.org/10.3389/fonc.2023.1151500 |
work_keys_str_mv | AT wangsiqi thevalueofdcemriofthebreastasadiagnostictoolinassessingamorphouscalcificationsinscreeningmammography AT wanghui thevalueofdcemriofthebreastasadiagnostictoolinassessingamorphouscalcificationsinscreeningmammography AT liyang thevalueofdcemriofthebreastasadiagnostictoolinassessingamorphouscalcificationsinscreeningmammography AT loujianjuan thevalueofdcemriofthebreastasadiagnostictoolinassessingamorphouscalcificationsinscreeningmammography AT zouqigui thevalueofdcemriofthebreastasadiagnostictoolinassessingamorphouscalcificationsinscreeningmammography AT jiangyanni thevalueofdcemriofthebreastasadiagnostictoolinassessingamorphouscalcificationsinscreeningmammography AT wufeiyun thevalueofdcemriofthebreastasadiagnostictoolinassessingamorphouscalcificationsinscreeningmammography AT tangyuxia thevalueofdcemriofthebreastasadiagnostictoolinassessingamorphouscalcificationsinscreeningmammography AT wangshouju thevalueofdcemriofthebreastasadiagnostictoolinassessingamorphouscalcificationsinscreeningmammography AT wangsiqi valueofdcemriofthebreastasadiagnostictoolinassessingamorphouscalcificationsinscreeningmammography AT wanghui valueofdcemriofthebreastasadiagnostictoolinassessingamorphouscalcificationsinscreeningmammography AT liyang valueofdcemriofthebreastasadiagnostictoolinassessingamorphouscalcificationsinscreeningmammography AT loujianjuan valueofdcemriofthebreastasadiagnostictoolinassessingamorphouscalcificationsinscreeningmammography AT zouqigui valueofdcemriofthebreastasadiagnostictoolinassessingamorphouscalcificationsinscreeningmammography AT jiangyanni valueofdcemriofthebreastasadiagnostictoolinassessingamorphouscalcificationsinscreeningmammography AT wufeiyun valueofdcemriofthebreastasadiagnostictoolinassessingamorphouscalcificationsinscreeningmammography AT tangyuxia valueofdcemriofthebreastasadiagnostictoolinassessingamorphouscalcificationsinscreeningmammography AT wangshouju valueofdcemriofthebreastasadiagnostictoolinassessingamorphouscalcificationsinscreeningmammography |