Cargando…
Whole-Cerebrum distortion-free three-dimensional pseudo-Continuous Arterial Spin Labeling at 7T
Fulfilling potentials of ultrahigh field for pseudo-Continuous Arterial Spin Labeling (pCASL) has been hampered by B1/B0 inhomogeneities that affect pCASL labeling, background suppression (BS), and the readout sequence. This study aimed to present a whole-cerebrum distortion-free three-dimensional (...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Cold Spring Harbor Laboratory
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10168494/ https://www.ncbi.nlm.nih.gov/pubmed/37163115 http://dx.doi.org/10.1101/2023.04.24.23289051 |
_version_ | 1785038865303601152 |
---|---|
author | Zhao, Chenyang Shao, Xingfeng Shou, Qinyang Ma, Samantha J. Gokyar, Sayim Graf, Christina Stollberger, Rudolf Wang, Danny JJ |
author_facet | Zhao, Chenyang Shao, Xingfeng Shou, Qinyang Ma, Samantha J. Gokyar, Sayim Graf, Christina Stollberger, Rudolf Wang, Danny JJ |
author_sort | Zhao, Chenyang |
collection | PubMed |
description | Fulfilling potentials of ultrahigh field for pseudo-Continuous Arterial Spin Labeling (pCASL) has been hampered by B1/B0 inhomogeneities that affect pCASL labeling, background suppression (BS), and the readout sequence. This study aimed to present a whole-cerebrum distortion-free three-dimensional (3D) pCASL sequence at 7T by optimizing pCASL labeling parameters, BS pulses, and an accelerated Turbo-FLASH (TFL) readout. A new set of pCASL labeling parameters (G(ave)=0.4mT/m, G(ratio)=14.67) was proposed to avoid interferences in bottom slices while achieving robust labeling efficiency (LE). An OPTIM BS pulse was designed based on the range of B1/B0 inhomogeneities at 7T. A 3D TFL readout with 2D-CAIPIRINHA undersampling (R=2×2) and centric ordering was developed, and the number of segments (N(seg)) and flip angle (FA) were varied in simulation to achieve the optimal trade-off between SNR and spatial blurring. In-vivo experiments were performed on 19 subjects. The results showed that the new set of labeling parameters effectively achieved whole-cerebrum coverage by eliminating interferences in bottom slices while maintaining a high LE. The OPTIM BS pulse achieved 33.3% higher perfusion signal in gray matter (GM) than the original BS pulse with a cost of 4.8-fold SAR. Incorporating a moderate FA (8°) and N(seg) (2), whole-cerebrum 3D TFL-pCASL imaging was achieved with a 2×2×4 mm(3) resolution without distortion and susceptibility artifacts compared to 3D GRASE-pCASL. In addition, 3D TFL-pCASL showed a good to excellent test-retest repeatability and potential of higher resolution (2 mm isotropic). The proposed technique also significantly improved SNR when compared to the same sequence at 3T and simultaneous multislice TFL-pCASL at 7T. By combining a new set of labeling parameters, OPTIM BS pulse, and accelerated 3D TFL readout, we achieved high resolution pCASL at 7T with whole-cerebrum coverage, detailed perfusion and anatomical information without distortion, and sufficient SNR. |
format | Online Article Text |
id | pubmed-10168494 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Cold Spring Harbor Laboratory |
record_format | MEDLINE/PubMed |
spelling | pubmed-101684942023-05-10 Whole-Cerebrum distortion-free three-dimensional pseudo-Continuous Arterial Spin Labeling at 7T Zhao, Chenyang Shao, Xingfeng Shou, Qinyang Ma, Samantha J. Gokyar, Sayim Graf, Christina Stollberger, Rudolf Wang, Danny JJ medRxiv Article Fulfilling potentials of ultrahigh field for pseudo-Continuous Arterial Spin Labeling (pCASL) has been hampered by B1/B0 inhomogeneities that affect pCASL labeling, background suppression (BS), and the readout sequence. This study aimed to present a whole-cerebrum distortion-free three-dimensional (3D) pCASL sequence at 7T by optimizing pCASL labeling parameters, BS pulses, and an accelerated Turbo-FLASH (TFL) readout. A new set of pCASL labeling parameters (G(ave)=0.4mT/m, G(ratio)=14.67) was proposed to avoid interferences in bottom slices while achieving robust labeling efficiency (LE). An OPTIM BS pulse was designed based on the range of B1/B0 inhomogeneities at 7T. A 3D TFL readout with 2D-CAIPIRINHA undersampling (R=2×2) and centric ordering was developed, and the number of segments (N(seg)) and flip angle (FA) were varied in simulation to achieve the optimal trade-off between SNR and spatial blurring. In-vivo experiments were performed on 19 subjects. The results showed that the new set of labeling parameters effectively achieved whole-cerebrum coverage by eliminating interferences in bottom slices while maintaining a high LE. The OPTIM BS pulse achieved 33.3% higher perfusion signal in gray matter (GM) than the original BS pulse with a cost of 4.8-fold SAR. Incorporating a moderate FA (8°) and N(seg) (2), whole-cerebrum 3D TFL-pCASL imaging was achieved with a 2×2×4 mm(3) resolution without distortion and susceptibility artifacts compared to 3D GRASE-pCASL. In addition, 3D TFL-pCASL showed a good to excellent test-retest repeatability and potential of higher resolution (2 mm isotropic). The proposed technique also significantly improved SNR when compared to the same sequence at 3T and simultaneous multislice TFL-pCASL at 7T. By combining a new set of labeling parameters, OPTIM BS pulse, and accelerated 3D TFL readout, we achieved high resolution pCASL at 7T with whole-cerebrum coverage, detailed perfusion and anatomical information without distortion, and sufficient SNR. Cold Spring Harbor Laboratory 2023-04-25 /pmc/articles/PMC10168494/ /pubmed/37163115 http://dx.doi.org/10.1101/2023.04.24.23289051 Text en https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License (https://creativecommons.org/licenses/by-nc-nd/4.0/) , which allows reusers to copy and distribute the material in any medium or format in unadapted form only, for noncommercial purposes only, and only so long as attribution is given to the creator. |
spellingShingle | Article Zhao, Chenyang Shao, Xingfeng Shou, Qinyang Ma, Samantha J. Gokyar, Sayim Graf, Christina Stollberger, Rudolf Wang, Danny JJ Whole-Cerebrum distortion-free three-dimensional pseudo-Continuous Arterial Spin Labeling at 7T |
title | Whole-Cerebrum distortion-free three-dimensional pseudo-Continuous Arterial Spin Labeling at 7T |
title_full | Whole-Cerebrum distortion-free three-dimensional pseudo-Continuous Arterial Spin Labeling at 7T |
title_fullStr | Whole-Cerebrum distortion-free three-dimensional pseudo-Continuous Arterial Spin Labeling at 7T |
title_full_unstemmed | Whole-Cerebrum distortion-free three-dimensional pseudo-Continuous Arterial Spin Labeling at 7T |
title_short | Whole-Cerebrum distortion-free three-dimensional pseudo-Continuous Arterial Spin Labeling at 7T |
title_sort | whole-cerebrum distortion-free three-dimensional pseudo-continuous arterial spin labeling at 7t |
topic | Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10168494/ https://www.ncbi.nlm.nih.gov/pubmed/37163115 http://dx.doi.org/10.1101/2023.04.24.23289051 |
work_keys_str_mv | AT zhaochenyang wholecerebrumdistortionfreethreedimensionalpseudocontinuousarterialspinlabelingat7t AT shaoxingfeng wholecerebrumdistortionfreethreedimensionalpseudocontinuousarterialspinlabelingat7t AT shouqinyang wholecerebrumdistortionfreethreedimensionalpseudocontinuousarterialspinlabelingat7t AT masamanthaj wholecerebrumdistortionfreethreedimensionalpseudocontinuousarterialspinlabelingat7t AT gokyarsayim wholecerebrumdistortionfreethreedimensionalpseudocontinuousarterialspinlabelingat7t AT grafchristina wholecerebrumdistortionfreethreedimensionalpseudocontinuousarterialspinlabelingat7t AT stollbergerrudolf wholecerebrumdistortionfreethreedimensionalpseudocontinuousarterialspinlabelingat7t AT wangdannyjj wholecerebrumdistortionfreethreedimensionalpseudocontinuousarterialspinlabelingat7t |