A Wireless, Wearable Carotid Doppler Ultrasound Aids Diagnosis and Monitoring of Pericardial Tamponade: A Case Report

Pericardial tamponade can often be diagnosed through clinical findings and echocardiography; however, the diagnosis can be aided by demonstrating the hemodynamic consequences of the effusion. We describe the use of a wearable carotid Doppler device to help diagnose and monitor pericardial tamponade....

Descripción completa

Detalles Bibliográficos
Autores principales: Prager, Ross, Pratte, Michael, Kenny, Jon-Emile, Rola, Philippe
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Lippincott Williams & Wilkins 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10168526/
https://www.ncbi.nlm.nih.gov/pubmed/37181538
http://dx.doi.org/10.1097/CCE.0000000000000911
_version_ 1785038872045944832
author Prager, Ross
Pratte, Michael
Kenny, Jon-Emile
Rola, Philippe
author_facet Prager, Ross
Pratte, Michael
Kenny, Jon-Emile
Rola, Philippe
author_sort Prager, Ross
collection PubMed
description Pericardial tamponade can often be diagnosed through clinical findings and echocardiography; however, the diagnosis can be aided by demonstrating the hemodynamic consequences of the effusion. We describe the use of a wearable carotid Doppler device to help diagnose and monitor pericardial tamponade. CASE SUMMARY: A 54-year-old man developed hypotension after an endobronchial biopsy for a lung mass. Echocardiography showed a pericardial effusion with sonographic evidence of tamponade. A wearable carotid Doppler device demonstrated low corrected carotid flow time (CFT) (a surrogate for stroke volume) with significant respiratory variation, supporting the diagnosis of tamponade. The patient underwent pericardiocentesis which revealed purulent pericardial fluid from a mediastinal abscess. After drainage there was increased CFT and reduced respiratory variability in Doppler, surrogates of improved stroke volume. CONCLUSION: A wearable carotid Doppler device is a noninvasive tool that can help determine the hemodynamic impact of a pericardial effusion, and potentially aid in the diagnosis of pericardial tamponade.
format Online
Article
Text
id pubmed-10168526
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Lippincott Williams & Wilkins
record_format MEDLINE/PubMed
spelling pubmed-101685262023-05-10 A Wireless, Wearable Carotid Doppler Ultrasound Aids Diagnosis and Monitoring of Pericardial Tamponade: A Case Report Prager, Ross Pratte, Michael Kenny, Jon-Emile Rola, Philippe Crit Care Explor Case Report Pericardial tamponade can often be diagnosed through clinical findings and echocardiography; however, the diagnosis can be aided by demonstrating the hemodynamic consequences of the effusion. We describe the use of a wearable carotid Doppler device to help diagnose and monitor pericardial tamponade. CASE SUMMARY: A 54-year-old man developed hypotension after an endobronchial biopsy for a lung mass. Echocardiography showed a pericardial effusion with sonographic evidence of tamponade. A wearable carotid Doppler device demonstrated low corrected carotid flow time (CFT) (a surrogate for stroke volume) with significant respiratory variation, supporting the diagnosis of tamponade. The patient underwent pericardiocentesis which revealed purulent pericardial fluid from a mediastinal abscess. After drainage there was increased CFT and reduced respiratory variability in Doppler, surrogates of improved stroke volume. CONCLUSION: A wearable carotid Doppler device is a noninvasive tool that can help determine the hemodynamic impact of a pericardial effusion, and potentially aid in the diagnosis of pericardial tamponade. Lippincott Williams & Wilkins 2023-05-08 /pmc/articles/PMC10168526/ /pubmed/37181538 http://dx.doi.org/10.1097/CCE.0000000000000911 Text en Copyright © 2023 The Authors. Published by Wolters Kluwer Health, Inc. on behalf of the Society of Critical Care Medicine. https://creativecommons.org/licenses/by-nc-nd/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND) (https://creativecommons.org/licenses/by-nc-nd/4.0/) , where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.
spellingShingle Case Report
Prager, Ross
Pratte, Michael
Kenny, Jon-Emile
Rola, Philippe
A Wireless, Wearable Carotid Doppler Ultrasound Aids Diagnosis and Monitoring of Pericardial Tamponade: A Case Report
title A Wireless, Wearable Carotid Doppler Ultrasound Aids Diagnosis and Monitoring of Pericardial Tamponade: A Case Report
title_full A Wireless, Wearable Carotid Doppler Ultrasound Aids Diagnosis and Monitoring of Pericardial Tamponade: A Case Report
title_fullStr A Wireless, Wearable Carotid Doppler Ultrasound Aids Diagnosis and Monitoring of Pericardial Tamponade: A Case Report
title_full_unstemmed A Wireless, Wearable Carotid Doppler Ultrasound Aids Diagnosis and Monitoring of Pericardial Tamponade: A Case Report
title_short A Wireless, Wearable Carotid Doppler Ultrasound Aids Diagnosis and Monitoring of Pericardial Tamponade: A Case Report
title_sort wireless, wearable carotid doppler ultrasound aids diagnosis and monitoring of pericardial tamponade: a case report
topic Case Report
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10168526/
https://www.ncbi.nlm.nih.gov/pubmed/37181538
http://dx.doi.org/10.1097/CCE.0000000000000911
work_keys_str_mv AT pragerross awirelesswearablecarotiddopplerultrasoundaidsdiagnosisandmonitoringofpericardialtamponadeacasereport
AT prattemichael awirelesswearablecarotiddopplerultrasoundaidsdiagnosisandmonitoringofpericardialtamponadeacasereport
AT kennyjonemile awirelesswearablecarotiddopplerultrasoundaidsdiagnosisandmonitoringofpericardialtamponadeacasereport
AT rolaphilippe awirelesswearablecarotiddopplerultrasoundaidsdiagnosisandmonitoringofpericardialtamponadeacasereport
AT pragerross wirelesswearablecarotiddopplerultrasoundaidsdiagnosisandmonitoringofpericardialtamponadeacasereport
AT prattemichael wirelesswearablecarotiddopplerultrasoundaidsdiagnosisandmonitoringofpericardialtamponadeacasereport
AT kennyjonemile wirelesswearablecarotiddopplerultrasoundaidsdiagnosisandmonitoringofpericardialtamponadeacasereport
AT rolaphilippe wirelesswearablecarotiddopplerultrasoundaidsdiagnosisandmonitoringofpericardialtamponadeacasereport