Cargando…

Repeatability of Choroidal Thickness Measurements in Healthy Subjects using RTVue XR Optical Coherence Tomography

PURPOSE: To determine the intrasession, intraobserver, interobserver, and repeatability of choroidal thickness measurements in the healthy subjects imaged on enhanced depth imaging system of RTVue XR spectral domain optical coherence tomography (OCT). METHODS: In this prospective, cross-sectional st...

Descripción completa

Detalles Bibliográficos
Autores principales: Mansoori, Tarannum, Charan, Aknoor Sree Ram, Suresh, Narala, Pesala, Veerendranath, Nagalla, Balakrishna
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10170977/
https://www.ncbi.nlm.nih.gov/pubmed/37180531
http://dx.doi.org/10.4103/joco.joco_168_22
_version_ 1785039332323622912
author Mansoori, Tarannum
Charan, Aknoor Sree Ram
Suresh, Narala
Pesala, Veerendranath
Nagalla, Balakrishna
author_facet Mansoori, Tarannum
Charan, Aknoor Sree Ram
Suresh, Narala
Pesala, Veerendranath
Nagalla, Balakrishna
author_sort Mansoori, Tarannum
collection PubMed
description PURPOSE: To determine the intrasession, intraobserver, interobserver, and repeatability of choroidal thickness measurements in the healthy subjects imaged on enhanced depth imaging system of RTVue XR spectral domain optical coherence tomography (OCT). METHODS: In this prospective, cross-sectional study, seventy eyes of 70 healthy volunteers with no known ocular disease were imaged using high-density scanning protocol of RTVue XR OCT. In a single imaging session, three sequential 12 mm macular-enhanced depth horizontal line scans were obtained through the fovea. Two experienced examiners measured the subfoveal choroidal thickness (SFCT), choroidal thickness at 500 μm nasally and temporally from the fovea in all the eyes, using the manual calipers provided in the software. The graders were masked to each other's measurement readings. The coefficient of repeatability (CR) and intraclass correlation coefficient (ICC) were used to measure the reliability within graders. Intergrader variability was assessed using Bland-Altman method and 95% limits of agreement (LoA). RESULTS: Intragrader CR for grader one was 4.11 μm (95% confidence interval [CI], −2.84–11.06) for SFCT and 5.73 μm (95% CI, −3.71–15.16) for the grader two. Intragrader ICC of grader one ranged from 0.996 for SFCT to 0.994 for temporal choroidal thickness. Intragrader ICC of grader two ranged from 0.993 for temporal choroidal thickness to 0.991 for SFCT. Intergrader CR ranged from 5.24 μm (95% CI, −4.66–15.15) for SFCT to 5.89 μm (95% CI, −7.27–19.04) for temporal choroidal thickness. Intergrader 95% LoA for SFCT, nasal and temporal choroidal thickness were, −15.84–12.15 μm, −15.99–17.7 μm, and − 19.12–15.57 μm, respectively. CONCLUSION: Choroidal thickness measurements can be quantified with good repeatability using RTVue XR OCT, which would be useful in patients with chorioretinal diseases.
format Online
Article
Text
id pubmed-10170977
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-101709772023-05-11 Repeatability of Choroidal Thickness Measurements in Healthy Subjects using RTVue XR Optical Coherence Tomography Mansoori, Tarannum Charan, Aknoor Sree Ram Suresh, Narala Pesala, Veerendranath Nagalla, Balakrishna J Curr Ophthalmol Original Article PURPOSE: To determine the intrasession, intraobserver, interobserver, and repeatability of choroidal thickness measurements in the healthy subjects imaged on enhanced depth imaging system of RTVue XR spectral domain optical coherence tomography (OCT). METHODS: In this prospective, cross-sectional study, seventy eyes of 70 healthy volunteers with no known ocular disease were imaged using high-density scanning protocol of RTVue XR OCT. In a single imaging session, three sequential 12 mm macular-enhanced depth horizontal line scans were obtained through the fovea. Two experienced examiners measured the subfoveal choroidal thickness (SFCT), choroidal thickness at 500 μm nasally and temporally from the fovea in all the eyes, using the manual calipers provided in the software. The graders were masked to each other's measurement readings. The coefficient of repeatability (CR) and intraclass correlation coefficient (ICC) were used to measure the reliability within graders. Intergrader variability was assessed using Bland-Altman method and 95% limits of agreement (LoA). RESULTS: Intragrader CR for grader one was 4.11 μm (95% confidence interval [CI], −2.84–11.06) for SFCT and 5.73 μm (95% CI, −3.71–15.16) for the grader two. Intragrader ICC of grader one ranged from 0.996 for SFCT to 0.994 for temporal choroidal thickness. Intragrader ICC of grader two ranged from 0.993 for temporal choroidal thickness to 0.991 for SFCT. Intergrader CR ranged from 5.24 μm (95% CI, −4.66–15.15) for SFCT to 5.89 μm (95% CI, −7.27–19.04) for temporal choroidal thickness. Intergrader 95% LoA for SFCT, nasal and temporal choroidal thickness were, −15.84–12.15 μm, −15.99–17.7 μm, and − 19.12–15.57 μm, respectively. CONCLUSION: Choroidal thickness measurements can be quantified with good repeatability using RTVue XR OCT, which would be useful in patients with chorioretinal diseases. Wolters Kluwer - Medknow 2023-04-29 /pmc/articles/PMC10170977/ /pubmed/37180531 http://dx.doi.org/10.4103/joco.joco_168_22 Text en Copyright: © 2023 Journal of Current Ophthalmology https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Mansoori, Tarannum
Charan, Aknoor Sree Ram
Suresh, Narala
Pesala, Veerendranath
Nagalla, Balakrishna
Repeatability of Choroidal Thickness Measurements in Healthy Subjects using RTVue XR Optical Coherence Tomography
title Repeatability of Choroidal Thickness Measurements in Healthy Subjects using RTVue XR Optical Coherence Tomography
title_full Repeatability of Choroidal Thickness Measurements in Healthy Subjects using RTVue XR Optical Coherence Tomography
title_fullStr Repeatability of Choroidal Thickness Measurements in Healthy Subjects using RTVue XR Optical Coherence Tomography
title_full_unstemmed Repeatability of Choroidal Thickness Measurements in Healthy Subjects using RTVue XR Optical Coherence Tomography
title_short Repeatability of Choroidal Thickness Measurements in Healthy Subjects using RTVue XR Optical Coherence Tomography
title_sort repeatability of choroidal thickness measurements in healthy subjects using rtvue xr optical coherence tomography
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10170977/
https://www.ncbi.nlm.nih.gov/pubmed/37180531
http://dx.doi.org/10.4103/joco.joco_168_22
work_keys_str_mv AT mansooritarannum repeatabilityofchoroidalthicknessmeasurementsinhealthysubjectsusingrtvuexropticalcoherencetomography
AT charanaknoorsreeram repeatabilityofchoroidalthicknessmeasurementsinhealthysubjectsusingrtvuexropticalcoherencetomography
AT sureshnarala repeatabilityofchoroidalthicknessmeasurementsinhealthysubjectsusingrtvuexropticalcoherencetomography
AT pesalaveerendranath repeatabilityofchoroidalthicknessmeasurementsinhealthysubjectsusingrtvuexropticalcoherencetomography
AT nagallabalakrishna repeatabilityofchoroidalthicknessmeasurementsinhealthysubjectsusingrtvuexropticalcoherencetomography