Corneal Biomechanical Changes after Corneal Cross-Linking in Patients with Keratoconus
PURPOSE: To evaluate the changes in biomechanical properties of the cornea using the Corvis ST device after the treatment of keratoconus patients with ultraviolet-A/riboflavin corneal cross-linking (CXL). METHODS: Thirty-seven eyes from 37 consecutive patients with progressive keratoconus were inclu...
Autores principales: | , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10170983/ https://www.ncbi.nlm.nih.gov/pubmed/37180532 http://dx.doi.org/10.4103/joco.joco_177_21 |
_version_ | 1785039333717180416 |
---|---|
author | Hamid, Adel Jahadi-Hosseini, Hamidreza Khalili, Mohammad Reza Jahanbani-Ardakani, Hamidreza |
author_facet | Hamid, Adel Jahadi-Hosseini, Hamidreza Khalili, Mohammad Reza Jahanbani-Ardakani, Hamidreza |
author_sort | Hamid, Adel |
collection | PubMed |
description | PURPOSE: To evaluate the changes in biomechanical properties of the cornea using the Corvis ST device after the treatment of keratoconus patients with ultraviolet-A/riboflavin corneal cross-linking (CXL). METHODS: Thirty-seven eyes from 37 consecutive patients with progressive keratoconus were included in this prospective observational case series. Corneal biomechanical parameters including the length of the applanated cornea (L1 and L2), corneal movement velocity during applanation (V1 and V2) at the moment of the first and second applanation, deformation amplitude (DA), distance between bending points of the cornea points of the cornea (PD), and concave radius of curvature (R) at the point of the highest concavity were recorded using the Corvis ST at baseline, 3 months, and 1 year after CXL. RESULTS: The mean age of the patients was 23.27 years (range, 19–31 years). Among CorVis ST corneal biomechanical parameters, L1, DA, PD, and R at the point of the highest concavity did not change significantly. The length of the applanated cornea at the moment of second applanation (L2) showed a significant change 3 months after CXL, but no significant difference was found between the 3-month and 1-year values of this parameter. Corneal movement velocity during applanation (V1 and V2) did not change 3 months after doing CXL, but the changes in these parameters were significant 1 year after CXL. CONCLUSIONS: Although the CorVis ST device may detect changes in some biomechanical properties of cornea after the treatment of keratoconus patients with CXL, many parameters remain unchanged, and this device cannot readily be used to find the effects of CXL. |
format | Online Article Text |
id | pubmed-10170983 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-101709832023-05-11 Corneal Biomechanical Changes after Corneal Cross-Linking in Patients with Keratoconus Hamid, Adel Jahadi-Hosseini, Hamidreza Khalili, Mohammad Reza Jahanbani-Ardakani, Hamidreza J Curr Ophthalmol Original Article PURPOSE: To evaluate the changes in biomechanical properties of the cornea using the Corvis ST device after the treatment of keratoconus patients with ultraviolet-A/riboflavin corneal cross-linking (CXL). METHODS: Thirty-seven eyes from 37 consecutive patients with progressive keratoconus were included in this prospective observational case series. Corneal biomechanical parameters including the length of the applanated cornea (L1 and L2), corneal movement velocity during applanation (V1 and V2) at the moment of the first and second applanation, deformation amplitude (DA), distance between bending points of the cornea points of the cornea (PD), and concave radius of curvature (R) at the point of the highest concavity were recorded using the Corvis ST at baseline, 3 months, and 1 year after CXL. RESULTS: The mean age of the patients was 23.27 years (range, 19–31 years). Among CorVis ST corneal biomechanical parameters, L1, DA, PD, and R at the point of the highest concavity did not change significantly. The length of the applanated cornea at the moment of second applanation (L2) showed a significant change 3 months after CXL, but no significant difference was found between the 3-month and 1-year values of this parameter. Corneal movement velocity during applanation (V1 and V2) did not change 3 months after doing CXL, but the changes in these parameters were significant 1 year after CXL. CONCLUSIONS: Although the CorVis ST device may detect changes in some biomechanical properties of cornea after the treatment of keratoconus patients with CXL, many parameters remain unchanged, and this device cannot readily be used to find the effects of CXL. Wolters Kluwer - Medknow 2023-04-29 /pmc/articles/PMC10170983/ /pubmed/37180532 http://dx.doi.org/10.4103/joco.joco_177_21 Text en Copyright: © 2023 Journal of Current Ophthalmology https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Hamid, Adel Jahadi-Hosseini, Hamidreza Khalili, Mohammad Reza Jahanbani-Ardakani, Hamidreza Corneal Biomechanical Changes after Corneal Cross-Linking in Patients with Keratoconus |
title | Corneal Biomechanical Changes after Corneal Cross-Linking in Patients with Keratoconus |
title_full | Corneal Biomechanical Changes after Corneal Cross-Linking in Patients with Keratoconus |
title_fullStr | Corneal Biomechanical Changes after Corneal Cross-Linking in Patients with Keratoconus |
title_full_unstemmed | Corneal Biomechanical Changes after Corneal Cross-Linking in Patients with Keratoconus |
title_short | Corneal Biomechanical Changes after Corneal Cross-Linking in Patients with Keratoconus |
title_sort | corneal biomechanical changes after corneal cross-linking in patients with keratoconus |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10170983/ https://www.ncbi.nlm.nih.gov/pubmed/37180532 http://dx.doi.org/10.4103/joco.joco_177_21 |
work_keys_str_mv | AT hamidadel cornealbiomechanicalchangesaftercornealcrosslinkinginpatientswithkeratoconus AT jahadihosseinihamidreza cornealbiomechanicalchangesaftercornealcrosslinkinginpatientswithkeratoconus AT khalilimohammadreza cornealbiomechanicalchangesaftercornealcrosslinkinginpatientswithkeratoconus AT jahanbaniardakanihamidreza cornealbiomechanicalchangesaftercornealcrosslinkinginpatientswithkeratoconus |