Corneal Biomechanical Changes after Corneal Cross-Linking in Patients with Keratoconus

PURPOSE: To evaluate the changes in biomechanical properties of the cornea using the Corvis ST device after the treatment of keratoconus patients with ultraviolet-A/riboflavin corneal cross-linking (CXL). METHODS: Thirty-seven eyes from 37 consecutive patients with progressive keratoconus were inclu...

Descripción completa

Detalles Bibliográficos
Autores principales: Hamid, Adel, Jahadi-Hosseini, Hamidreza, Khalili, Mohammad Reza, Jahanbani-Ardakani, Hamidreza
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10170983/
https://www.ncbi.nlm.nih.gov/pubmed/37180532
http://dx.doi.org/10.4103/joco.joco_177_21
_version_ 1785039333717180416
author Hamid, Adel
Jahadi-Hosseini, Hamidreza
Khalili, Mohammad Reza
Jahanbani-Ardakani, Hamidreza
author_facet Hamid, Adel
Jahadi-Hosseini, Hamidreza
Khalili, Mohammad Reza
Jahanbani-Ardakani, Hamidreza
author_sort Hamid, Adel
collection PubMed
description PURPOSE: To evaluate the changes in biomechanical properties of the cornea using the Corvis ST device after the treatment of keratoconus patients with ultraviolet-A/riboflavin corneal cross-linking (CXL). METHODS: Thirty-seven eyes from 37 consecutive patients with progressive keratoconus were included in this prospective observational case series. Corneal biomechanical parameters including the length of the applanated cornea (L1 and L2), corneal movement velocity during applanation (V1 and V2) at the moment of the first and second applanation, deformation amplitude (DA), distance between bending points of the cornea points of the cornea (PD), and concave radius of curvature (R) at the point of the highest concavity were recorded using the Corvis ST at baseline, 3 months, and 1 year after CXL. RESULTS: The mean age of the patients was 23.27 years (range, 19–31 years). Among CorVis ST corneal biomechanical parameters, L1, DA, PD, and R at the point of the highest concavity did not change significantly. The length of the applanated cornea at the moment of second applanation (L2) showed a significant change 3 months after CXL, but no significant difference was found between the 3-month and 1-year values of this parameter. Corneal movement velocity during applanation (V1 and V2) did not change 3 months after doing CXL, but the changes in these parameters were significant 1 year after CXL. CONCLUSIONS: Although the CorVis ST device may detect changes in some biomechanical properties of cornea after the treatment of keratoconus patients with CXL, many parameters remain unchanged, and this device cannot readily be used to find the effects of CXL.
format Online
Article
Text
id pubmed-10170983
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-101709832023-05-11 Corneal Biomechanical Changes after Corneal Cross-Linking in Patients with Keratoconus Hamid, Adel Jahadi-Hosseini, Hamidreza Khalili, Mohammad Reza Jahanbani-Ardakani, Hamidreza J Curr Ophthalmol Original Article PURPOSE: To evaluate the changes in biomechanical properties of the cornea using the Corvis ST device after the treatment of keratoconus patients with ultraviolet-A/riboflavin corneal cross-linking (CXL). METHODS: Thirty-seven eyes from 37 consecutive patients with progressive keratoconus were included in this prospective observational case series. Corneal biomechanical parameters including the length of the applanated cornea (L1 and L2), corneal movement velocity during applanation (V1 and V2) at the moment of the first and second applanation, deformation amplitude (DA), distance between bending points of the cornea points of the cornea (PD), and concave radius of curvature (R) at the point of the highest concavity were recorded using the Corvis ST at baseline, 3 months, and 1 year after CXL. RESULTS: The mean age of the patients was 23.27 years (range, 19–31 years). Among CorVis ST corneal biomechanical parameters, L1, DA, PD, and R at the point of the highest concavity did not change significantly. The length of the applanated cornea at the moment of second applanation (L2) showed a significant change 3 months after CXL, but no significant difference was found between the 3-month and 1-year values of this parameter. Corneal movement velocity during applanation (V1 and V2) did not change 3 months after doing CXL, but the changes in these parameters were significant 1 year after CXL. CONCLUSIONS: Although the CorVis ST device may detect changes in some biomechanical properties of cornea after the treatment of keratoconus patients with CXL, many parameters remain unchanged, and this device cannot readily be used to find the effects of CXL. Wolters Kluwer - Medknow 2023-04-29 /pmc/articles/PMC10170983/ /pubmed/37180532 http://dx.doi.org/10.4103/joco.joco_177_21 Text en Copyright: © 2023 Journal of Current Ophthalmology https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Hamid, Adel
Jahadi-Hosseini, Hamidreza
Khalili, Mohammad Reza
Jahanbani-Ardakani, Hamidreza
Corneal Biomechanical Changes after Corneal Cross-Linking in Patients with Keratoconus
title Corneal Biomechanical Changes after Corneal Cross-Linking in Patients with Keratoconus
title_full Corneal Biomechanical Changes after Corneal Cross-Linking in Patients with Keratoconus
title_fullStr Corneal Biomechanical Changes after Corneal Cross-Linking in Patients with Keratoconus
title_full_unstemmed Corneal Biomechanical Changes after Corneal Cross-Linking in Patients with Keratoconus
title_short Corneal Biomechanical Changes after Corneal Cross-Linking in Patients with Keratoconus
title_sort corneal biomechanical changes after corneal cross-linking in patients with keratoconus
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10170983/
https://www.ncbi.nlm.nih.gov/pubmed/37180532
http://dx.doi.org/10.4103/joco.joco_177_21
work_keys_str_mv AT hamidadel cornealbiomechanicalchangesaftercornealcrosslinkinginpatientswithkeratoconus
AT jahadihosseinihamidreza cornealbiomechanicalchangesaftercornealcrosslinkinginpatientswithkeratoconus
AT khalilimohammadreza cornealbiomechanicalchangesaftercornealcrosslinkinginpatientswithkeratoconus
AT jahanbaniardakanihamidreza cornealbiomechanicalchangesaftercornealcrosslinkinginpatientswithkeratoconus