Cargando…

A New Criterion for Shear Wave Elastometric Assessment Using Modulus of Stiffness Difference between Object and Environment

Ultrasound shear wave elastography is a modern method that is based on measuring the shear wave velocity making it possible to determine stiffness of soft biological tissues at an arbitrary point (point elastography) or to construct a two-dimensional color image with a subsequent point measurement o...

Descripción completa

Detalles Bibliográficos
Autores principales: Demin, I.Yu., Rykhtik, P.I., Spivak, А.E., Safonov, D.V.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Privolzhsky Research Medical University 2022
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10171064/
https://www.ncbi.nlm.nih.gov/pubmed/37181832
http://dx.doi.org/10.17691/stm2022.14.5.01
_version_ 1785039352313675776
author Demin, I.Yu.
Rykhtik, P.I.
Spivak, А.E.
Safonov, D.V.
author_facet Demin, I.Yu.
Rykhtik, P.I.
Spivak, А.E.
Safonov, D.V.
author_sort Demin, I.Yu.
collection PubMed
description Ultrasound shear wave elastography is a modern method that is based on measuring the shear wave velocity making it possible to determine stiffness of soft biological tissues at an arbitrary point (point elastography) or to construct a two-dimensional color image with a subsequent point measurement of stiffness (two-dimensional elastography) and therefore to compare the stiffness of an object with a medium or objects with each other. The aim of the study is to develop a new criterion for the comparative assessment of objects with different stiffness during shear wave elastometry: modulus of stiffness difference between object and environment. MATERIALS AND METHODS: Using the original technology of building two-dimensional color elastogram, point and two-dimensional shear wave elastography were performed using linear sensors on commercial ultrasound scanners: Aixplorer (SuperSonic Imagine, France), Acuson S2000 (Siemens, Germany), and Verasonics acoustic system (Verasonics Inc., USA) with an open architecture to determine the stiffness values of focal inclusions and compare them with each other with the help of a new comparative elastomeric assessment criterion: modulus of stiffness difference between object and environment. First, the accuracy of the scanners under test was compared on a calibrated Elasticity QA Phantom, model 049 (Computerized Imaging Reference Systems Company, USA) with a known stiffness of various inclusions and thereafter on an uncalibrated BP1901 phantom (Blue Phantom, USA) with unknown stiffness of inclusions. The obtained values were compared to determine the influence of subjective factors on the measurement results. RESULTS: To assess the stiffness of the foci and compare the values with each other taking into account the rigidity of the environment, it is proposed to use a new criterion for the comparative assessment — the modulus of stiffness difference between focus and environment, which quantitatively characterizes the difference between these values. According to this criterion, all three ultrasound scanners have been established to show high and comparable accuracy in determining the stiffness of inclusions within the homogeneous medium in the experiments on phantoms. Two-dimensional shear wave elastography has revealed the effect of the control volume size and the correctness of the color scale setting, especially in the heterogeneous objects, on the results of elastometry. Methodological techniques to reduce the influence of subjective factors have also been proposed. CONCLUSION: The study has showed the possibility of using the modulus of stiffness difference between object and environment as a new criterion for comparative assessment of objects in shear wave elastometry taking into account stiffness of the environment. To reduce operator-dependence, it is necessary to take into consideration both the way of realizing elastometry (point or two-dimensional color elastography) and a number of other methodological factors.
format Online
Article
Text
id pubmed-10171064
institution National Center for Biotechnology Information
language English
publishDate 2022
publisher Privolzhsky Research Medical University
record_format MEDLINE/PubMed
spelling pubmed-101710642023-05-11 A New Criterion for Shear Wave Elastometric Assessment Using Modulus of Stiffness Difference between Object and Environment Demin, I.Yu. Rykhtik, P.I. Spivak, А.E. Safonov, D.V. Sovrem Tekhnologii Med Advanced Researches Ultrasound shear wave elastography is a modern method that is based on measuring the shear wave velocity making it possible to determine stiffness of soft biological tissues at an arbitrary point (point elastography) or to construct a two-dimensional color image with a subsequent point measurement of stiffness (two-dimensional elastography) and therefore to compare the stiffness of an object with a medium or objects with each other. The aim of the study is to develop a new criterion for the comparative assessment of objects with different stiffness during shear wave elastometry: modulus of stiffness difference between object and environment. MATERIALS AND METHODS: Using the original technology of building two-dimensional color elastogram, point and two-dimensional shear wave elastography were performed using linear sensors on commercial ultrasound scanners: Aixplorer (SuperSonic Imagine, France), Acuson S2000 (Siemens, Germany), and Verasonics acoustic system (Verasonics Inc., USA) with an open architecture to determine the stiffness values of focal inclusions and compare them with each other with the help of a new comparative elastomeric assessment criterion: modulus of stiffness difference between object and environment. First, the accuracy of the scanners under test was compared on a calibrated Elasticity QA Phantom, model 049 (Computerized Imaging Reference Systems Company, USA) with a known stiffness of various inclusions and thereafter on an uncalibrated BP1901 phantom (Blue Phantom, USA) with unknown stiffness of inclusions. The obtained values were compared to determine the influence of subjective factors on the measurement results. RESULTS: To assess the stiffness of the foci and compare the values with each other taking into account the rigidity of the environment, it is proposed to use a new criterion for the comparative assessment — the modulus of stiffness difference between focus and environment, which quantitatively characterizes the difference between these values. According to this criterion, all three ultrasound scanners have been established to show high and comparable accuracy in determining the stiffness of inclusions within the homogeneous medium in the experiments on phantoms. Two-dimensional shear wave elastography has revealed the effect of the control volume size and the correctness of the color scale setting, especially in the heterogeneous objects, on the results of elastometry. Methodological techniques to reduce the influence of subjective factors have also been proposed. CONCLUSION: The study has showed the possibility of using the modulus of stiffness difference between object and environment as a new criterion for comparative assessment of objects in shear wave elastometry taking into account stiffness of the environment. To reduce operator-dependence, it is necessary to take into consideration both the way of realizing elastometry (point or two-dimensional color elastography) and a number of other methodological factors. Privolzhsky Research Medical University 2022 2022-09-29 /pmc/articles/PMC10171064/ /pubmed/37181832 http://dx.doi.org/10.17691/stm2022.14.5.01 Text en https://creativecommons.org/licenses/by/4.0/This is an open access article under the CC BY 4.0 license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Advanced Researches
Demin, I.Yu.
Rykhtik, P.I.
Spivak, А.E.
Safonov, D.V.
A New Criterion for Shear Wave Elastometric Assessment Using Modulus of Stiffness Difference between Object and Environment
title A New Criterion for Shear Wave Elastometric Assessment Using Modulus of Stiffness Difference between Object and Environment
title_full A New Criterion for Shear Wave Elastometric Assessment Using Modulus of Stiffness Difference between Object and Environment
title_fullStr A New Criterion for Shear Wave Elastometric Assessment Using Modulus of Stiffness Difference between Object and Environment
title_full_unstemmed A New Criterion for Shear Wave Elastometric Assessment Using Modulus of Stiffness Difference between Object and Environment
title_short A New Criterion for Shear Wave Elastometric Assessment Using Modulus of Stiffness Difference between Object and Environment
title_sort new criterion for shear wave elastometric assessment using modulus of stiffness difference between object and environment
topic Advanced Researches
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10171064/
https://www.ncbi.nlm.nih.gov/pubmed/37181832
http://dx.doi.org/10.17691/stm2022.14.5.01
work_keys_str_mv AT deminiyu anewcriterionforshearwaveelastometricassessmentusingmodulusofstiffnessdifferencebetweenobjectandenvironment
AT rykhtikpi anewcriterionforshearwaveelastometricassessmentusingmodulusofstiffnessdifferencebetweenobjectandenvironment
AT spivakae anewcriterionforshearwaveelastometricassessmentusingmodulusofstiffnessdifferencebetweenobjectandenvironment
AT safonovdv anewcriterionforshearwaveelastometricassessmentusingmodulusofstiffnessdifferencebetweenobjectandenvironment
AT deminiyu newcriterionforshearwaveelastometricassessmentusingmodulusofstiffnessdifferencebetweenobjectandenvironment
AT rykhtikpi newcriterionforshearwaveelastometricassessmentusingmodulusofstiffnessdifferencebetweenobjectandenvironment
AT spivakae newcriterionforshearwaveelastometricassessmentusingmodulusofstiffnessdifferencebetweenobjectandenvironment
AT safonovdv newcriterionforshearwaveelastometricassessmentusingmodulusofstiffnessdifferencebetweenobjectandenvironment