Cargando…
99m-Tc MDP Bone Scan Image Enhancement using Pipeline Application of Dynamic Stochastic Resonance Algorithm and Block-Matching 3D Filter
INTRODUCTION: In this pilot study, we have proposed and evaluated pipelined application of the dynamic stochastic resonance (DSR) algorithm and block-matching 3D (BM3D) filter for the enhancement of nuclear medicine images. The enhanced images out of the pipeline were compared with the corresponding...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Wolters Kluwer - Medknow
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10171760/ https://www.ncbi.nlm.nih.gov/pubmed/37180179 http://dx.doi.org/10.4103/ijnm.ijnm_78_22 |
_version_ | 1785039491734437888 |
---|---|
author | Pandey, Anil Kumar Kaur, Gagandeep Chaudhary, Jagrati Hemrom, Angel Jaleel, Jasim Sharma, Param Dev Patel, Chetan Kumar, Rakesh |
author_facet | Pandey, Anil Kumar Kaur, Gagandeep Chaudhary, Jagrati Hemrom, Angel Jaleel, Jasim Sharma, Param Dev Patel, Chetan Kumar, Rakesh |
author_sort | Pandey, Anil Kumar |
collection | PubMed |
description | INTRODUCTION: In this pilot study, we have proposed and evaluated pipelined application of the dynamic stochastic resonance (DSR) algorithm and block-matching 3D (BM3D) filter for the enhancement of nuclear medicine images. The enhanced images out of the pipeline were compared with the corresponding enhanced images obtained using individual applications of DSR and BM3D algorithm. MATERIALS AND METHODS: Twenty 99m-Tc MDP bone scan images acquired on SymbiaT6 SPECT/CT gamma camera system fitted with low-energy high-resolution collimators were exported in DICOM format to a personal computer and converted into PNG format. These PNG images were processed using the proposed algorithm in MATLAB. Two nuclear medicine physicians visually compared each input and its corresponding three enhanced images to select the best-enhanced image. The image quality metrics (Brightness, Global Contrast Factor (GCF), Contrast per pixel (CPP), and Blur) were used to assess the image quality objectively. The Wilcoxon signed test was applied to find a statistically significant difference in Brightness, GCF, CPP, and Blur of enhanced and its input images at a level of significance. RESULTS: Images enhanced using the pipelined application of SR and BM3D were selected as the best images by both nuclear medicine physicians. Based on Brightness, Global Contrast Factor (GCF), CPP, and Blur, the image quality of our proposed pipeline was significantly better than enhanced images obtained using individual applications of DSR and BM3D algorithm. The proposed method was found to be very successful in enhancing details in the low count region of input images. The enhanced images were bright, smooth, and had better target-to-background ratio compared to input images. CONCLUSION: The pipelined application of DSR and BM3D algorithm produced enhancement in nuclear medicine images having following characteristics: bright, smooth, better target-to-background ratio, and improved visibility of details in the low count regions of the input image, as compared to individual enhancements by application of DSR or BM3D algorithm. |
format | Online Article Text |
id | pubmed-10171760 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | Wolters Kluwer - Medknow |
record_format | MEDLINE/PubMed |
spelling | pubmed-101717602023-05-11 99m-Tc MDP Bone Scan Image Enhancement using Pipeline Application of Dynamic Stochastic Resonance Algorithm and Block-Matching 3D Filter Pandey, Anil Kumar Kaur, Gagandeep Chaudhary, Jagrati Hemrom, Angel Jaleel, Jasim Sharma, Param Dev Patel, Chetan Kumar, Rakesh Indian J Nucl Med Original Article INTRODUCTION: In this pilot study, we have proposed and evaluated pipelined application of the dynamic stochastic resonance (DSR) algorithm and block-matching 3D (BM3D) filter for the enhancement of nuclear medicine images. The enhanced images out of the pipeline were compared with the corresponding enhanced images obtained using individual applications of DSR and BM3D algorithm. MATERIALS AND METHODS: Twenty 99m-Tc MDP bone scan images acquired on SymbiaT6 SPECT/CT gamma camera system fitted with low-energy high-resolution collimators were exported in DICOM format to a personal computer and converted into PNG format. These PNG images were processed using the proposed algorithm in MATLAB. Two nuclear medicine physicians visually compared each input and its corresponding three enhanced images to select the best-enhanced image. The image quality metrics (Brightness, Global Contrast Factor (GCF), Contrast per pixel (CPP), and Blur) were used to assess the image quality objectively. The Wilcoxon signed test was applied to find a statistically significant difference in Brightness, GCF, CPP, and Blur of enhanced and its input images at a level of significance. RESULTS: Images enhanced using the pipelined application of SR and BM3D were selected as the best images by both nuclear medicine physicians. Based on Brightness, Global Contrast Factor (GCF), CPP, and Blur, the image quality of our proposed pipeline was significantly better than enhanced images obtained using individual applications of DSR and BM3D algorithm. The proposed method was found to be very successful in enhancing details in the low count region of input images. The enhanced images were bright, smooth, and had better target-to-background ratio compared to input images. CONCLUSION: The pipelined application of DSR and BM3D algorithm produced enhancement in nuclear medicine images having following characteristics: bright, smooth, better target-to-background ratio, and improved visibility of details in the low count regions of the input image, as compared to individual enhancements by application of DSR or BM3D algorithm. Wolters Kluwer - Medknow 2023 2023-02-24 /pmc/articles/PMC10171760/ /pubmed/37180179 http://dx.doi.org/10.4103/ijnm.ijnm_78_22 Text en Copyright: © 2023 Indian Journal of Nuclear Medicine https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms. |
spellingShingle | Original Article Pandey, Anil Kumar Kaur, Gagandeep Chaudhary, Jagrati Hemrom, Angel Jaleel, Jasim Sharma, Param Dev Patel, Chetan Kumar, Rakesh 99m-Tc MDP Bone Scan Image Enhancement using Pipeline Application of Dynamic Stochastic Resonance Algorithm and Block-Matching 3D Filter |
title | 99m-Tc MDP Bone Scan Image Enhancement using Pipeline Application of Dynamic Stochastic Resonance Algorithm and Block-Matching 3D Filter |
title_full | 99m-Tc MDP Bone Scan Image Enhancement using Pipeline Application of Dynamic Stochastic Resonance Algorithm and Block-Matching 3D Filter |
title_fullStr | 99m-Tc MDP Bone Scan Image Enhancement using Pipeline Application of Dynamic Stochastic Resonance Algorithm and Block-Matching 3D Filter |
title_full_unstemmed | 99m-Tc MDP Bone Scan Image Enhancement using Pipeline Application of Dynamic Stochastic Resonance Algorithm and Block-Matching 3D Filter |
title_short | 99m-Tc MDP Bone Scan Image Enhancement using Pipeline Application of Dynamic Stochastic Resonance Algorithm and Block-Matching 3D Filter |
title_sort | 99m-tc mdp bone scan image enhancement using pipeline application of dynamic stochastic resonance algorithm and block-matching 3d filter |
topic | Original Article |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10171760/ https://www.ncbi.nlm.nih.gov/pubmed/37180179 http://dx.doi.org/10.4103/ijnm.ijnm_78_22 |
work_keys_str_mv | AT pandeyanilkumar 99mtcmdpbonescanimageenhancementusingpipelineapplicationofdynamicstochasticresonancealgorithmandblockmatching3dfilter AT kaurgagandeep 99mtcmdpbonescanimageenhancementusingpipelineapplicationofdynamicstochasticresonancealgorithmandblockmatching3dfilter AT chaudharyjagrati 99mtcmdpbonescanimageenhancementusingpipelineapplicationofdynamicstochasticresonancealgorithmandblockmatching3dfilter AT hemromangel 99mtcmdpbonescanimageenhancementusingpipelineapplicationofdynamicstochasticresonancealgorithmandblockmatching3dfilter AT jaleeljasim 99mtcmdpbonescanimageenhancementusingpipelineapplicationofdynamicstochasticresonancealgorithmandblockmatching3dfilter AT sharmaparamdev 99mtcmdpbonescanimageenhancementusingpipelineapplicationofdynamicstochasticresonancealgorithmandblockmatching3dfilter AT patelchetan 99mtcmdpbonescanimageenhancementusingpipelineapplicationofdynamicstochasticresonancealgorithmandblockmatching3dfilter AT kumarrakesh 99mtcmdpbonescanimageenhancementusingpipelineapplicationofdynamicstochasticresonancealgorithmandblockmatching3dfilter |