Cargando…

The Usefulness of Bioelectrical Impedance as a Marker of Fluid Status in Patients With Congestive Heart Failure: A Systematic Review and Meta-Analysis

Bioelectrical impedance analysis (BIA) is a method that measures electrical currents conducted through water, which assesses fluid status by measuring extracellular water (ECW), total body water (TBW), and resistance (R). Limited studies are done to evaluate the utility of BIA in patients with conge...

Descripción completa

Detalles Bibliográficos
Autores principales: Hanna, Daniel, Baig, Iftekhar, Subbiondo, Robert, Iqbal, Umair
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Cureus 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10171872/
https://www.ncbi.nlm.nih.gov/pubmed/37181968
http://dx.doi.org/10.7759/cureus.37377
_version_ 1785039514213810176
author Hanna, Daniel
Baig, Iftekhar
Subbiondo, Robert
Iqbal, Umair
author_facet Hanna, Daniel
Baig, Iftekhar
Subbiondo, Robert
Iqbal, Umair
author_sort Hanna, Daniel
collection PubMed
description Bioelectrical impedance analysis (BIA) is a method that measures electrical currents conducted through water, which assesses fluid status by measuring extracellular water (ECW), total body water (TBW), and resistance (R). Limited studies are done to evaluate the utility of BIA in patients with congestive heart failure (CHF), and therefore, we performed a systematic review and meta-analysis to evaluate this. A comprehensive literature search was performed at Medline and Embase until March 2022. Our primary outcome was a comparison of TBW and ECW between patients with CHF and controls. Our secondary outcome was to compare R between the groups. All analysis was conducted using RevMan 5.4 software. Six studies with 1,046 patients met our inclusion criteria. Out of 1,046 patients, 526 had CHF and 538 had no CHF. Among patients with CHF, all 526 had decompensated CHF. There was no significant difference in TBW between patients with heart failure and the control group (mean deviation (MD) = 1.42 (-0.44-3.27), percent of variation (I2) = 0%, p = 0.13). ECW was significantly higher with an assessment of BIA in heart failure patients compared to patients in the control group (MD = 1.62 (0.82-2.42), I2 = 0%, p < 0.0001). Resistance of extracellular fluid was significantly lower in the heart failure group (MD = -45.64 (-72.88--18.41), I2 = 83%, p = 0.001). Publication bias was deferred as the number of included studies was less than 10. BIA can be helpful in ambulatory and inpatient setting to identify patients’ fluid status, which can improve outcomes. However, larger prospective studies are needed to further evaluate the usefulness of BIA in the CHF population.
format Online
Article
Text
id pubmed-10171872
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Cureus
record_format MEDLINE/PubMed
spelling pubmed-101718722023-05-11 The Usefulness of Bioelectrical Impedance as a Marker of Fluid Status in Patients With Congestive Heart Failure: A Systematic Review and Meta-Analysis Hanna, Daniel Baig, Iftekhar Subbiondo, Robert Iqbal, Umair Cureus Cardiology Bioelectrical impedance analysis (BIA) is a method that measures electrical currents conducted through water, which assesses fluid status by measuring extracellular water (ECW), total body water (TBW), and resistance (R). Limited studies are done to evaluate the utility of BIA in patients with congestive heart failure (CHF), and therefore, we performed a systematic review and meta-analysis to evaluate this. A comprehensive literature search was performed at Medline and Embase until March 2022. Our primary outcome was a comparison of TBW and ECW between patients with CHF and controls. Our secondary outcome was to compare R between the groups. All analysis was conducted using RevMan 5.4 software. Six studies with 1,046 patients met our inclusion criteria. Out of 1,046 patients, 526 had CHF and 538 had no CHF. Among patients with CHF, all 526 had decompensated CHF. There was no significant difference in TBW between patients with heart failure and the control group (mean deviation (MD) = 1.42 (-0.44-3.27), percent of variation (I2) = 0%, p = 0.13). ECW was significantly higher with an assessment of BIA in heart failure patients compared to patients in the control group (MD = 1.62 (0.82-2.42), I2 = 0%, p < 0.0001). Resistance of extracellular fluid was significantly lower in the heart failure group (MD = -45.64 (-72.88--18.41), I2 = 83%, p = 0.001). Publication bias was deferred as the number of included studies was less than 10. BIA can be helpful in ambulatory and inpatient setting to identify patients’ fluid status, which can improve outcomes. However, larger prospective studies are needed to further evaluate the usefulness of BIA in the CHF population. Cureus 2023-04-10 /pmc/articles/PMC10171872/ /pubmed/37181968 http://dx.doi.org/10.7759/cureus.37377 Text en Copyright © 2023, Hanna et al. https://creativecommons.org/licenses/by/3.0/This is an open access article distributed under the terms of the Creative Commons Attribution License, which permits unrestricted use, distribution, and reproduction in any medium, provided the original author and source are credited.
spellingShingle Cardiology
Hanna, Daniel
Baig, Iftekhar
Subbiondo, Robert
Iqbal, Umair
The Usefulness of Bioelectrical Impedance as a Marker of Fluid Status in Patients With Congestive Heart Failure: A Systematic Review and Meta-Analysis
title The Usefulness of Bioelectrical Impedance as a Marker of Fluid Status in Patients With Congestive Heart Failure: A Systematic Review and Meta-Analysis
title_full The Usefulness of Bioelectrical Impedance as a Marker of Fluid Status in Patients With Congestive Heart Failure: A Systematic Review and Meta-Analysis
title_fullStr The Usefulness of Bioelectrical Impedance as a Marker of Fluid Status in Patients With Congestive Heart Failure: A Systematic Review and Meta-Analysis
title_full_unstemmed The Usefulness of Bioelectrical Impedance as a Marker of Fluid Status in Patients With Congestive Heart Failure: A Systematic Review and Meta-Analysis
title_short The Usefulness of Bioelectrical Impedance as a Marker of Fluid Status in Patients With Congestive Heart Failure: A Systematic Review and Meta-Analysis
title_sort usefulness of bioelectrical impedance as a marker of fluid status in patients with congestive heart failure: a systematic review and meta-analysis
topic Cardiology
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10171872/
https://www.ncbi.nlm.nih.gov/pubmed/37181968
http://dx.doi.org/10.7759/cureus.37377
work_keys_str_mv AT hannadaniel theusefulnessofbioelectricalimpedanceasamarkeroffluidstatusinpatientswithcongestiveheartfailureasystematicreviewandmetaanalysis
AT baigiftekhar theusefulnessofbioelectricalimpedanceasamarkeroffluidstatusinpatientswithcongestiveheartfailureasystematicreviewandmetaanalysis
AT subbiondorobert theusefulnessofbioelectricalimpedanceasamarkeroffluidstatusinpatientswithcongestiveheartfailureasystematicreviewandmetaanalysis
AT iqbalumair theusefulnessofbioelectricalimpedanceasamarkeroffluidstatusinpatientswithcongestiveheartfailureasystematicreviewandmetaanalysis
AT hannadaniel usefulnessofbioelectricalimpedanceasamarkeroffluidstatusinpatientswithcongestiveheartfailureasystematicreviewandmetaanalysis
AT baigiftekhar usefulnessofbioelectricalimpedanceasamarkeroffluidstatusinpatientswithcongestiveheartfailureasystematicreviewandmetaanalysis
AT subbiondorobert usefulnessofbioelectricalimpedanceasamarkeroffluidstatusinpatientswithcongestiveheartfailureasystematicreviewandmetaanalysis
AT iqbalumair usefulnessofbioelectricalimpedanceasamarkeroffluidstatusinpatientswithcongestiveheartfailureasystematicreviewandmetaanalysis