Intraoral occlusal adjustment time and volume required for CAD/CAM crowns fabricated with different virtual mounting methods (A randomized crossover trial)
OBJECTIVE: To measure the required clinical time and volume of occlusal adjustment when the maxillary cast is positioned in a virtual articulator using one of three methods: digitization of a facebow-mounted mechanical articulator (group A), virtual Bonwill triangle (group B) or a 3D face scan (grou...
Autores principales: | , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Nature Publishing Group UK
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10172387/ https://www.ncbi.nlm.nih.gov/pubmed/37164989 http://dx.doi.org/10.1038/s41405-023-00146-8 |
Sumario: | OBJECTIVE: To measure the required clinical time and volume of occlusal adjustment when the maxillary cast is positioned in a virtual articulator using one of three methods: digitization of a facebow-mounted mechanical articulator (group A), virtual Bonwill triangle (group B) or a 3D face scan (group F). MATERIALS AND METHODS: In this randomized, triple-blind, crossover trial; 11 participants were enrolled. Every participant had one molar indicated for a single crown restoration. Three crowns were designed and milled for every participant molar totaling 33 crowns. Each of the three crowns was fabricated with the participant’s casts virtually mounted utilizing a different method. An impression was taken of the crown in place before occlusal adjustment. The occlusal adjustment was then performed and timed with the three crowns in the different groups. After the occlusal adjustment, an impression of the adjusted crown was taken. The pre-adjustment and post-adjustment impressions were digitally superimposed and the volume difference was measured. The Kruskal-Wallis test was used to compare the groups. RESULTS: Group A showed the shortest mean adjustment time (3:44.59 ± 3:39.07) followed by group F (4:30.09 ± 2:01.50) and group B (4:35.30 ± 2:32.33). The mean adjustment volume for group A was (28 ± 19.1 mm(3)) followed by group F (30.5 ± 18.8 mm(3)) and group B (40.6 ± 29.5 mm(3)). Different virtual mounting methods had no statistically significant effect on adjustment time (P-value = 0.538) or adjustment volume (P-value = 0.490). CONCLUSIONS: A simplified approach in virtual articulator mounting appears to be justified in the construction of a single full-coverage prosthesis. Added labor, time and cost of more elaborate virtual mounting methods seem to be counterproductive. |
---|