Cargando…

Assessing the effect of manufacturing defects and non-Newtonian blood model on flow behaviors of additively manufactured Gyroid TPMS structures

In the field of medical engineering, Triply Periodic Minimal Surfaces (TPMS) structures have been studied widely owing to their physical attributes similar to those of human bones. Computational Fluid Dynamics (CFD) is often used to reveal the interaction between structural architectures and flow fi...

Descripción completa

Detalles Bibliográficos
Autores principales: Seehanam, Saran, Chanchareon, Wares, Promoppatum, Patcharapit
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Elsevier 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10172759/
https://www.ncbi.nlm.nih.gov/pubmed/37180920
http://dx.doi.org/10.1016/j.heliyon.2023.e15711

Ejemplares similares