Cargando…
A novel biplanar positioning technique to guide iliosacral screw insertion: a retrospective study
PURPOSE: To evaluate the safety and benefits of the biplanar position technique on operative time, radiation exposure, and screw placement accuracy. METHODS: In this study, we retrospectively evaluated the records of 64 patients with pelvic fractures (Tile B and C) between October 2020 and September...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
BioMed Central
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10173659/ https://www.ncbi.nlm.nih.gov/pubmed/37170257 http://dx.doi.org/10.1186/s12891-023-06482-y |
_version_ | 1785039870008229888 |
---|---|
author | Zhao, Yangyang Cui, Pengju Xiong, Zhenggang Zheng, Jiachun Xing, Deguo |
author_facet | Zhao, Yangyang Cui, Pengju Xiong, Zhenggang Zheng, Jiachun Xing, Deguo |
author_sort | Zhao, Yangyang |
collection | PubMed |
description | PURPOSE: To evaluate the safety and benefits of the biplanar position technique on operative time, radiation exposure, and screw placement accuracy. METHODS: In this study, we retrospectively evaluated the records of 64 patients with pelvic fractures (Tile B and C) between October 2020 and September 2021. According to the surgical methods selected by the patients, the patients were divided into a biplanar positioning technique group (biplanar group), a Ti-robot navigation group (Ti-robot group), and a traditional fluoroscopy-guided technique group (traditional group). Length of operation, blood loss, intra-operative radiation exposure fracture reduction, and the quality of screw positioning were compared among the three groups. RESULTS: One hundred three screws were implanted in 64 patients (biplanar group 22, Ti-robot group 21, traditional group 21). The average operation time was significantly less in the biplanar group (26.32 ± 6.32 min) than in the traditional group (79.24 ± 11.31 min), but significantly more than in the Ti-robot group (15.81 ± 3.9 min). The radiation exposure was similar in the biplanar group (740.53 ± 185.91 cGy/cm2) and Ti-robot group (678.44 ± 127.16 cGy/cm2), both of which were significantly more than in the traditional group (2034.58 ± 494.54 cGy/cm2). The intra-operative blooding loss was similar in the biplanar group (12.76 ± 3.77 mL) and the Ti-robot group (11.92 ± 4.67 mL), both of which were significantly less than in the traditional group (29.7 ± 8.01 mL). The Screw perforation was slightly lower in the biplanar group (94.1%) than in the Ti-robot group (97.2%) but was significantly higher than in the traditional group (75.7%). CONCLUSIONS: The biplanar positioning technique is as accurate and safe as computer-navigated systems for percutaneous iliosacral screw insertion, associated with shorter surgical time, lower intra-operative radiation exposure, and more accuracy compared to traditional fluoroscopy. |
format | Online Article Text |
id | pubmed-10173659 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | BioMed Central |
record_format | MEDLINE/PubMed |
spelling | pubmed-101736592023-05-12 A novel biplanar positioning technique to guide iliosacral screw insertion: a retrospective study Zhao, Yangyang Cui, Pengju Xiong, Zhenggang Zheng, Jiachun Xing, Deguo BMC Musculoskelet Disord Research PURPOSE: To evaluate the safety and benefits of the biplanar position technique on operative time, radiation exposure, and screw placement accuracy. METHODS: In this study, we retrospectively evaluated the records of 64 patients with pelvic fractures (Tile B and C) between October 2020 and September 2021. According to the surgical methods selected by the patients, the patients were divided into a biplanar positioning technique group (biplanar group), a Ti-robot navigation group (Ti-robot group), and a traditional fluoroscopy-guided technique group (traditional group). Length of operation, blood loss, intra-operative radiation exposure fracture reduction, and the quality of screw positioning were compared among the three groups. RESULTS: One hundred three screws were implanted in 64 patients (biplanar group 22, Ti-robot group 21, traditional group 21). The average operation time was significantly less in the biplanar group (26.32 ± 6.32 min) than in the traditional group (79.24 ± 11.31 min), but significantly more than in the Ti-robot group (15.81 ± 3.9 min). The radiation exposure was similar in the biplanar group (740.53 ± 185.91 cGy/cm2) and Ti-robot group (678.44 ± 127.16 cGy/cm2), both of which were significantly more than in the traditional group (2034.58 ± 494.54 cGy/cm2). The intra-operative blooding loss was similar in the biplanar group (12.76 ± 3.77 mL) and the Ti-robot group (11.92 ± 4.67 mL), both of which were significantly less than in the traditional group (29.7 ± 8.01 mL). The Screw perforation was slightly lower in the biplanar group (94.1%) than in the Ti-robot group (97.2%) but was significantly higher than in the traditional group (75.7%). CONCLUSIONS: The biplanar positioning technique is as accurate and safe as computer-navigated systems for percutaneous iliosacral screw insertion, associated with shorter surgical time, lower intra-operative radiation exposure, and more accuracy compared to traditional fluoroscopy. BioMed Central 2023-05-11 /pmc/articles/PMC10173659/ /pubmed/37170257 http://dx.doi.org/10.1186/s12891-023-06482-y Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open AccessThis article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) . The Creative Commons Public Domain Dedication waiver (http://creativecommons.org/publicdomain/zero/1.0/ (https://creativecommons.org/publicdomain/zero/1.0/) ) applies to the data made available in this article, unless otherwise stated in a credit line to the data. |
spellingShingle | Research Zhao, Yangyang Cui, Pengju Xiong, Zhenggang Zheng, Jiachun Xing, Deguo A novel biplanar positioning technique to guide iliosacral screw insertion: a retrospective study |
title | A novel biplanar positioning technique to guide iliosacral screw insertion: a retrospective study |
title_full | A novel biplanar positioning technique to guide iliosacral screw insertion: a retrospective study |
title_fullStr | A novel biplanar positioning technique to guide iliosacral screw insertion: a retrospective study |
title_full_unstemmed | A novel biplanar positioning technique to guide iliosacral screw insertion: a retrospective study |
title_short | A novel biplanar positioning technique to guide iliosacral screw insertion: a retrospective study |
title_sort | novel biplanar positioning technique to guide iliosacral screw insertion: a retrospective study |
topic | Research |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10173659/ https://www.ncbi.nlm.nih.gov/pubmed/37170257 http://dx.doi.org/10.1186/s12891-023-06482-y |
work_keys_str_mv | AT zhaoyangyang anovelbiplanarpositioningtechniquetoguideiliosacralscrewinsertionaretrospectivestudy AT cuipengju anovelbiplanarpositioningtechniquetoguideiliosacralscrewinsertionaretrospectivestudy AT xiongzhenggang anovelbiplanarpositioningtechniquetoguideiliosacralscrewinsertionaretrospectivestudy AT zhengjiachun anovelbiplanarpositioningtechniquetoguideiliosacralscrewinsertionaretrospectivestudy AT xingdeguo anovelbiplanarpositioningtechniquetoguideiliosacralscrewinsertionaretrospectivestudy AT zhaoyangyang novelbiplanarpositioningtechniquetoguideiliosacralscrewinsertionaretrospectivestudy AT cuipengju novelbiplanarpositioningtechniquetoguideiliosacralscrewinsertionaretrospectivestudy AT xiongzhenggang novelbiplanarpositioningtechniquetoguideiliosacralscrewinsertionaretrospectivestudy AT zhengjiachun novelbiplanarpositioningtechniquetoguideiliosacralscrewinsertionaretrospectivestudy AT xingdeguo novelbiplanarpositioningtechniquetoguideiliosacralscrewinsertionaretrospectivestudy |