Cargando…

Improvement in the ideal range of vault after implantable collamer lens implantation: a new vault prediction formula

BACKGROUND: To derive and validate a novel vault prediction formula to improve the predictability and safety of implantable collamer lens (ICL) implantation. METHODS: Thirty-five patients (61 eyes) with previous posterior chamber intraocular lens implantation were included. Various parameters, such...

Descripción completa

Detalles Bibliográficos
Autores principales: Wu, Hao, Zhong, Ding-juan, Luo, Dong-qiang, Zhang, Li-yuan, Liu, Jia, Wang, Hua
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Frontiers Media S.A. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10174235/
https://www.ncbi.nlm.nih.gov/pubmed/37181381
http://dx.doi.org/10.3389/fmed.2023.1132102
_version_ 1785039987085934592
author Wu, Hao
Zhong, Ding-juan
Luo, Dong-qiang
Zhang, Li-yuan
Liu, Jia
Wang, Hua
author_facet Wu, Hao
Zhong, Ding-juan
Luo, Dong-qiang
Zhang, Li-yuan
Liu, Jia
Wang, Hua
author_sort Wu, Hao
collection PubMed
description BACKGROUND: To derive and validate a novel vault prediction formula to improve the predictability and safety of implantable collamer lens (ICL) implantation. METHODS: Thirty-five patients (61 eyes) with previous posterior chamber intraocular lens implantation were included. Various parameters, such as horizontal-visible iris diameter (HVID), photopic pupil diameter (PPD), axial length (AL), white-to-white (WTW), anterior chamber width (ACW), angle-to-angle (ATA), crystalline lens rise (CLR), anterior chamber depth (ACD), horizontal sulcus-to-sulcus (HSTS), and ciliary sulcus angle (CSA) were measured. Vault was measured at 3 months after surgery using CASIA2 anterior segment optical coherence tomography. The formula was derived using multiple linear regression analysis and named as WH formula. It was validated in 65 patients (118 eyes) to determine the percentage of the ideal postoperative vault range and to compare the differences between the WH formula and the NK, KS, and STAAR formulas. RESULTS: Final ICL size, ATA, CSA, and CLR were included in the prediction formula model (adjusted R(2) = 0.67, p < 0.001). The achieved vault 1 month after the surgery was 556.19 μm ± 166.98 μm in the validation group, and the ideal vault range was 200–800 μm (92%). The difference between the achieved vault and that predicted using the WH formula was not statistically significant (p = 0.165), whereas the difference between the achieved vault and that predicted using the NK and KS formulas was statistically significant (p < 0.001 and p < 0.001, respectively). The 95% agreement limit range of the achieved vault and the vault predicted using the WH formula was narrower than those predicted using the NK and KS formulas (−295.20–258.82 μm). CONCLUSION: This study combined the results of optical coherence tomography and ultrasound biomicroscopy measurements of the anterior segment of the eye and incorporated ciliary sulcus morphology quantification into the prediction formula. The study derived a prediction formula for vault by combining ICL size, ATA, and CLR. The derived formula was found to be superior to the currently available formulas.
format Online
Article
Text
id pubmed-10174235
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Frontiers Media S.A.
record_format MEDLINE/PubMed
spelling pubmed-101742352023-05-12 Improvement in the ideal range of vault after implantable collamer lens implantation: a new vault prediction formula Wu, Hao Zhong, Ding-juan Luo, Dong-qiang Zhang, Li-yuan Liu, Jia Wang, Hua Front Med (Lausanne) Medicine BACKGROUND: To derive and validate a novel vault prediction formula to improve the predictability and safety of implantable collamer lens (ICL) implantation. METHODS: Thirty-five patients (61 eyes) with previous posterior chamber intraocular lens implantation were included. Various parameters, such as horizontal-visible iris diameter (HVID), photopic pupil diameter (PPD), axial length (AL), white-to-white (WTW), anterior chamber width (ACW), angle-to-angle (ATA), crystalline lens rise (CLR), anterior chamber depth (ACD), horizontal sulcus-to-sulcus (HSTS), and ciliary sulcus angle (CSA) were measured. Vault was measured at 3 months after surgery using CASIA2 anterior segment optical coherence tomography. The formula was derived using multiple linear regression analysis and named as WH formula. It was validated in 65 patients (118 eyes) to determine the percentage of the ideal postoperative vault range and to compare the differences between the WH formula and the NK, KS, and STAAR formulas. RESULTS: Final ICL size, ATA, CSA, and CLR were included in the prediction formula model (adjusted R(2) = 0.67, p < 0.001). The achieved vault 1 month after the surgery was 556.19 μm ± 166.98 μm in the validation group, and the ideal vault range was 200–800 μm (92%). The difference between the achieved vault and that predicted using the WH formula was not statistically significant (p = 0.165), whereas the difference between the achieved vault and that predicted using the NK and KS formulas was statistically significant (p < 0.001 and p < 0.001, respectively). The 95% agreement limit range of the achieved vault and the vault predicted using the WH formula was narrower than those predicted using the NK and KS formulas (−295.20–258.82 μm). CONCLUSION: This study combined the results of optical coherence tomography and ultrasound biomicroscopy measurements of the anterior segment of the eye and incorporated ciliary sulcus morphology quantification into the prediction formula. The study derived a prediction formula for vault by combining ICL size, ATA, and CLR. The derived formula was found to be superior to the currently available formulas. Frontiers Media S.A. 2023-04-27 /pmc/articles/PMC10174235/ /pubmed/37181381 http://dx.doi.org/10.3389/fmed.2023.1132102 Text en Copyright © 2023 Wu, Zhong, Luo, Zhang, Liu and Wang. https://creativecommons.org/licenses/by/4.0/This is an open-access article distributed under the terms of the Creative Commons Attribution License (CC BY). The use, distribution or reproduction in other forums is permitted, provided the original author(s) and the copyright owner(s) are credited and that the original publication in this journal is cited, in accordance with accepted academic practice. No use, distribution or reproduction is permitted which does not comply with these terms.
spellingShingle Medicine
Wu, Hao
Zhong, Ding-juan
Luo, Dong-qiang
Zhang, Li-yuan
Liu, Jia
Wang, Hua
Improvement in the ideal range of vault after implantable collamer lens implantation: a new vault prediction formula
title Improvement in the ideal range of vault after implantable collamer lens implantation: a new vault prediction formula
title_full Improvement in the ideal range of vault after implantable collamer lens implantation: a new vault prediction formula
title_fullStr Improvement in the ideal range of vault after implantable collamer lens implantation: a new vault prediction formula
title_full_unstemmed Improvement in the ideal range of vault after implantable collamer lens implantation: a new vault prediction formula
title_short Improvement in the ideal range of vault after implantable collamer lens implantation: a new vault prediction formula
title_sort improvement in the ideal range of vault after implantable collamer lens implantation: a new vault prediction formula
topic Medicine
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10174235/
https://www.ncbi.nlm.nih.gov/pubmed/37181381
http://dx.doi.org/10.3389/fmed.2023.1132102
work_keys_str_mv AT wuhao improvementintheidealrangeofvaultafterimplantablecollamerlensimplantationanewvaultpredictionformula
AT zhongdingjuan improvementintheidealrangeofvaultafterimplantablecollamerlensimplantationanewvaultpredictionformula
AT luodongqiang improvementintheidealrangeofvaultafterimplantablecollamerlensimplantationanewvaultpredictionformula
AT zhangliyuan improvementintheidealrangeofvaultafterimplantablecollamerlensimplantationanewvaultpredictionformula
AT liujia improvementintheidealrangeofvaultafterimplantablecollamerlensimplantationanewvaultpredictionformula
AT wanghua improvementintheidealrangeofvaultafterimplantablecollamerlensimplantationanewvaultpredictionformula