Cargando…

Evaluation of the One-Hour (13)C-Propionate Breath Test in 49 Patients from a Single Center in Japan to Detect Vitamin B(12) Deficiency

BACKGROUND: Given the unavailability of reliable biomarkers for vitamin B(12) (VB(12)) deficiency in clinical settings, the usefulness of the (13)C-propionate breath test (PBT), utilizing VB(12) as a coenzyme of methylmalonyl-CoA in propionate metabolism, as a diagnostic modality for VB(12) deficien...

Descripción completa

Detalles Bibliográficos
Autores principales: Sasaki, Yosuke, Sato, Takahiro, Maeda, Tadashi, Komatsu, Fumiya, Kawagoe, Naoyuki, Imai, Tsunehiko, Shigeta, Tomoyuki, Kashima, Naoyasu, Urita, Yoshihisa
Formato: Online Artículo Texto
Lenguaje:English
Publicado: International Scientific Literature, Inc. 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10177006/
https://www.ncbi.nlm.nih.gov/pubmed/37150974
http://dx.doi.org/10.12659/MSM.940238
_version_ 1785040536107745280
author Sasaki, Yosuke
Sato, Takahiro
Maeda, Tadashi
Komatsu, Fumiya
Kawagoe, Naoyuki
Imai, Tsunehiko
Shigeta, Tomoyuki
Kashima, Naoyasu
Urita, Yoshihisa
author_facet Sasaki, Yosuke
Sato, Takahiro
Maeda, Tadashi
Komatsu, Fumiya
Kawagoe, Naoyuki
Imai, Tsunehiko
Shigeta, Tomoyuki
Kashima, Naoyasu
Urita, Yoshihisa
author_sort Sasaki, Yosuke
collection PubMed
description BACKGROUND: Given the unavailability of reliable biomarkers for vitamin B(12) (VB(12)) deficiency in clinical settings, the usefulness of the (13)C-propionate breath test (PBT), utilizing VB(12) as a coenzyme of methylmalonyl-CoA in propionate metabolism, as a diagnostic modality for VB(12) deficiency has been studied. However, a collection time of 2 h reduces its convenience. Hence, we evaluated the effectiveness of 1-h PBT for detecting VB(12) deficiency in 49 patients with suspected VB(12) deficiency. MATERIAL/METHODS: We collected 100–200 mL breath gas every 10 min until 1 h after the administration of 1 g of (13)C-propionate from 49 patients (31 men, 18 women; median age, 70 years) with clinically suspected VB(12) deficiency and calculated the (13)CO(2) recovered in the breath per hour as the recovery rate (RR [%dose/h]) from (13)CO(2)/(12)CO(2) using infrared isotope spectrometry. We compared the RRs between groups: (1) with serum VB(12) levels ≥145 pg/mL and <145 pg/mL, (2) with mean corpuscular volume ≤100 fL and >100 fL, and 3) pre- and post-VB(12) supplementation. RESULTS: The RRs peaked within 30 min. The RRs at 20 min (RR(20)) and 30 min (RR(30)) were significantly lower in macrocytotic patients (41.28 vs 50.07, p=0.026 and 37.82 vs 43.93, P=0.003). The RR(30) was higher in the supplemented patients (41.93 vs 32.84, P=0.024). There was no significant difference in RRs between the patients with normal and low serum VB(12) levels. CONCLUSIONS: The 1-h PBT can be a diagnostic modality for VB(12) deficiency because 1 h is a sufficient collection time.
format Online
Article
Text
id pubmed-10177006
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher International Scientific Literature, Inc.
record_format MEDLINE/PubMed
spelling pubmed-101770062023-05-13 Evaluation of the One-Hour (13)C-Propionate Breath Test in 49 Patients from a Single Center in Japan to Detect Vitamin B(12) Deficiency Sasaki, Yosuke Sato, Takahiro Maeda, Tadashi Komatsu, Fumiya Kawagoe, Naoyuki Imai, Tsunehiko Shigeta, Tomoyuki Kashima, Naoyasu Urita, Yoshihisa Med Sci Monit Clinical Research BACKGROUND: Given the unavailability of reliable biomarkers for vitamin B(12) (VB(12)) deficiency in clinical settings, the usefulness of the (13)C-propionate breath test (PBT), utilizing VB(12) as a coenzyme of methylmalonyl-CoA in propionate metabolism, as a diagnostic modality for VB(12) deficiency has been studied. However, a collection time of 2 h reduces its convenience. Hence, we evaluated the effectiveness of 1-h PBT for detecting VB(12) deficiency in 49 patients with suspected VB(12) deficiency. MATERIAL/METHODS: We collected 100–200 mL breath gas every 10 min until 1 h after the administration of 1 g of (13)C-propionate from 49 patients (31 men, 18 women; median age, 70 years) with clinically suspected VB(12) deficiency and calculated the (13)CO(2) recovered in the breath per hour as the recovery rate (RR [%dose/h]) from (13)CO(2)/(12)CO(2) using infrared isotope spectrometry. We compared the RRs between groups: (1) with serum VB(12) levels ≥145 pg/mL and <145 pg/mL, (2) with mean corpuscular volume ≤100 fL and >100 fL, and 3) pre- and post-VB(12) supplementation. RESULTS: The RRs peaked within 30 min. The RRs at 20 min (RR(20)) and 30 min (RR(30)) were significantly lower in macrocytotic patients (41.28 vs 50.07, p=0.026 and 37.82 vs 43.93, P=0.003). The RR(30) was higher in the supplemented patients (41.93 vs 32.84, P=0.024). There was no significant difference in RRs between the patients with normal and low serum VB(12) levels. CONCLUSIONS: The 1-h PBT can be a diagnostic modality for VB(12) deficiency because 1 h is a sufficient collection time. International Scientific Literature, Inc. 2023-05-08 /pmc/articles/PMC10177006/ /pubmed/37150974 http://dx.doi.org/10.12659/MSM.940238 Text en © Med Sci Monit, 2023 https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under Creative Common Attribution-NonCommercial-NoDerivatives 4.0 International (CC BY-NC-ND 4.0 (https://creativecommons.org/licenses/by-nc-nd/4.0/) )
spellingShingle Clinical Research
Sasaki, Yosuke
Sato, Takahiro
Maeda, Tadashi
Komatsu, Fumiya
Kawagoe, Naoyuki
Imai, Tsunehiko
Shigeta, Tomoyuki
Kashima, Naoyasu
Urita, Yoshihisa
Evaluation of the One-Hour (13)C-Propionate Breath Test in 49 Patients from a Single Center in Japan to Detect Vitamin B(12) Deficiency
title Evaluation of the One-Hour (13)C-Propionate Breath Test in 49 Patients from a Single Center in Japan to Detect Vitamin B(12) Deficiency
title_full Evaluation of the One-Hour (13)C-Propionate Breath Test in 49 Patients from a Single Center in Japan to Detect Vitamin B(12) Deficiency
title_fullStr Evaluation of the One-Hour (13)C-Propionate Breath Test in 49 Patients from a Single Center in Japan to Detect Vitamin B(12) Deficiency
title_full_unstemmed Evaluation of the One-Hour (13)C-Propionate Breath Test in 49 Patients from a Single Center in Japan to Detect Vitamin B(12) Deficiency
title_short Evaluation of the One-Hour (13)C-Propionate Breath Test in 49 Patients from a Single Center in Japan to Detect Vitamin B(12) Deficiency
title_sort evaluation of the one-hour (13)c-propionate breath test in 49 patients from a single center in japan to detect vitamin b(12) deficiency
topic Clinical Research
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10177006/
https://www.ncbi.nlm.nih.gov/pubmed/37150974
http://dx.doi.org/10.12659/MSM.940238
work_keys_str_mv AT sasakiyosuke evaluationoftheonehour13cpropionatebreathtestin49patientsfromasinglecenterinjapantodetectvitaminb12deficiency
AT satotakahiro evaluationoftheonehour13cpropionatebreathtestin49patientsfromasinglecenterinjapantodetectvitaminb12deficiency
AT maedatadashi evaluationoftheonehour13cpropionatebreathtestin49patientsfromasinglecenterinjapantodetectvitaminb12deficiency
AT komatsufumiya evaluationoftheonehour13cpropionatebreathtestin49patientsfromasinglecenterinjapantodetectvitaminb12deficiency
AT kawagoenaoyuki evaluationoftheonehour13cpropionatebreathtestin49patientsfromasinglecenterinjapantodetectvitaminb12deficiency
AT imaitsunehiko evaluationoftheonehour13cpropionatebreathtestin49patientsfromasinglecenterinjapantodetectvitaminb12deficiency
AT shigetatomoyuki evaluationoftheonehour13cpropionatebreathtestin49patientsfromasinglecenterinjapantodetectvitaminb12deficiency
AT kashimanaoyasu evaluationoftheonehour13cpropionatebreathtestin49patientsfromasinglecenterinjapantodetectvitaminb12deficiency
AT uritayoshihisa evaluationoftheonehour13cpropionatebreathtestin49patientsfromasinglecenterinjapantodetectvitaminb12deficiency