Cargando…
High-resolution/High-Speed Gap Can Distinguish Different Intraretinal Perfusion Signals by Optical Coherence Tomography Angiography
PURPOSE: The development of optical coherence tomography angiography (OCTA) has radically changed the diagnostic assessment of the intraretinal vascular network. Two different OCTA acquisition modalities have recently been introduced in clinical practice, namely high-resolution (HR) and high-speed (...
Autores principales: | , , , , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
The Association for Research in Vision and Ophthalmology
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10179578/ https://www.ncbi.nlm.nih.gov/pubmed/37163285 http://dx.doi.org/10.1167/tvst.12.5.11 |
_version_ | 1785041131005804544 |
---|---|
author | Arrigo, Alessandro Teussink, Michel Bianco, Lorenzo Antropoli, Alessio Aragona, Emanuela Cappuccio, Giuseppe Bandello, Francesco Parodi, Maurizio Battaglia |
author_facet | Arrigo, Alessandro Teussink, Michel Bianco, Lorenzo Antropoli, Alessio Aragona, Emanuela Cappuccio, Giuseppe Bandello, Francesco Parodi, Maurizio Battaglia |
author_sort | Arrigo, Alessandro |
collection | PubMed |
description | PURPOSE: The development of optical coherence tomography angiography (OCTA) has radically changed the diagnostic assessment of the intraretinal vascular network. Two different OCTA acquisition modalities have recently been introduced in clinical practice, namely high-resolution (HR) and high-speed (HS) scans. HR OCTA requires more acquisition time and provides higher quality data, whereas HS OCTA is faster but furnishes lower quality data. The main aim of the present study is to gauge how much extra blood flow perfusion information can be obtained through the combined use of HR and HS OCTA. METHODS: We compared HR and HS OCTA acquisitions to assess the reliability of both techniques, also putting forward a new set of quantitative metrics to measure the HR/HS OCTA gap and to highlight different perfusion information. RESULTS: In essence, both HR and HS OCTA acquisitions proved highly feasible in detecting the intraretinal vascular flow signal, as confirmed by the stability of quantitative OCTA metrics, thus displaying their suitability for use in clinical practice. We detected an HR/HS overlapping gap of 21.6 ± 6.5% for intraretinal capillaries, and 4.3 ± 1.2% for choriocapillaris, highlighting the greater information obtained by HR OCTA. CONCLUSIONS: This novel HR/HS OCTA gap assessment might pave the way for the development of new quantitative metrics for retinal diseases that would focus on the earlier detection of perfusion impairment and relate it to the stage of the disease and its progression. TRANSLATIONAL RELEVANCE: This study proposes a new quantitative way to detect different perfusion signals based on OCTA. The findings presented in this paper can lay the foundations for the development of new quantitative metrics focused on the separate analysis of high flow and low flow signals, enabling very early changes in intraretinal perfusion to be detected. |
format | Online Article Text |
id | pubmed-10179578 |
institution | National Center for Biotechnology Information |
language | English |
publishDate | 2023 |
publisher | The Association for Research in Vision and Ophthalmology |
record_format | MEDLINE/PubMed |
spelling | pubmed-101795782023-05-13 High-resolution/High-Speed Gap Can Distinguish Different Intraretinal Perfusion Signals by Optical Coherence Tomography Angiography Arrigo, Alessandro Teussink, Michel Bianco, Lorenzo Antropoli, Alessio Aragona, Emanuela Cappuccio, Giuseppe Bandello, Francesco Parodi, Maurizio Battaglia Transl Vis Sci Technol Retina PURPOSE: The development of optical coherence tomography angiography (OCTA) has radically changed the diagnostic assessment of the intraretinal vascular network. Two different OCTA acquisition modalities have recently been introduced in clinical practice, namely high-resolution (HR) and high-speed (HS) scans. HR OCTA requires more acquisition time and provides higher quality data, whereas HS OCTA is faster but furnishes lower quality data. The main aim of the present study is to gauge how much extra blood flow perfusion information can be obtained through the combined use of HR and HS OCTA. METHODS: We compared HR and HS OCTA acquisitions to assess the reliability of both techniques, also putting forward a new set of quantitative metrics to measure the HR/HS OCTA gap and to highlight different perfusion information. RESULTS: In essence, both HR and HS OCTA acquisitions proved highly feasible in detecting the intraretinal vascular flow signal, as confirmed by the stability of quantitative OCTA metrics, thus displaying their suitability for use in clinical practice. We detected an HR/HS overlapping gap of 21.6 ± 6.5% for intraretinal capillaries, and 4.3 ± 1.2% for choriocapillaris, highlighting the greater information obtained by HR OCTA. CONCLUSIONS: This novel HR/HS OCTA gap assessment might pave the way for the development of new quantitative metrics for retinal diseases that would focus on the earlier detection of perfusion impairment and relate it to the stage of the disease and its progression. TRANSLATIONAL RELEVANCE: This study proposes a new quantitative way to detect different perfusion signals based on OCTA. The findings presented in this paper can lay the foundations for the development of new quantitative metrics focused on the separate analysis of high flow and low flow signals, enabling very early changes in intraretinal perfusion to be detected. The Association for Research in Vision and Ophthalmology 2023-05-10 /pmc/articles/PMC10179578/ /pubmed/37163285 http://dx.doi.org/10.1167/tvst.12.5.11 Text en Copyright 2023 The Authors https://creativecommons.org/licenses/by-nc-nd/4.0/This work is licensed under a Creative Commons Attribution-NonCommercial-NoDerivatives 4.0 International License. |
spellingShingle | Retina Arrigo, Alessandro Teussink, Michel Bianco, Lorenzo Antropoli, Alessio Aragona, Emanuela Cappuccio, Giuseppe Bandello, Francesco Parodi, Maurizio Battaglia High-resolution/High-Speed Gap Can Distinguish Different Intraretinal Perfusion Signals by Optical Coherence Tomography Angiography |
title | High-resolution/High-Speed Gap Can Distinguish Different Intraretinal Perfusion Signals by Optical Coherence Tomography Angiography |
title_full | High-resolution/High-Speed Gap Can Distinguish Different Intraretinal Perfusion Signals by Optical Coherence Tomography Angiography |
title_fullStr | High-resolution/High-Speed Gap Can Distinguish Different Intraretinal Perfusion Signals by Optical Coherence Tomography Angiography |
title_full_unstemmed | High-resolution/High-Speed Gap Can Distinguish Different Intraretinal Perfusion Signals by Optical Coherence Tomography Angiography |
title_short | High-resolution/High-Speed Gap Can Distinguish Different Intraretinal Perfusion Signals by Optical Coherence Tomography Angiography |
title_sort | high-resolution/high-speed gap can distinguish different intraretinal perfusion signals by optical coherence tomography angiography |
topic | Retina |
url | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10179578/ https://www.ncbi.nlm.nih.gov/pubmed/37163285 http://dx.doi.org/10.1167/tvst.12.5.11 |
work_keys_str_mv | AT arrigoalessandro highresolutionhighspeedgapcandistinguishdifferentintraretinalperfusionsignalsbyopticalcoherencetomographyangiography AT teussinkmichel highresolutionhighspeedgapcandistinguishdifferentintraretinalperfusionsignalsbyopticalcoherencetomographyangiography AT biancolorenzo highresolutionhighspeedgapcandistinguishdifferentintraretinalperfusionsignalsbyopticalcoherencetomographyangiography AT antropolialessio highresolutionhighspeedgapcandistinguishdifferentintraretinalperfusionsignalsbyopticalcoherencetomographyangiography AT aragonaemanuela highresolutionhighspeedgapcandistinguishdifferentintraretinalperfusionsignalsbyopticalcoherencetomographyangiography AT cappucciogiuseppe highresolutionhighspeedgapcandistinguishdifferentintraretinalperfusionsignalsbyopticalcoherencetomographyangiography AT bandellofrancesco highresolutionhighspeedgapcandistinguishdifferentintraretinalperfusionsignalsbyopticalcoherencetomographyangiography AT parodimauriziobattaglia highresolutionhighspeedgapcandistinguishdifferentintraretinalperfusionsignalsbyopticalcoherencetomographyangiography |