Cargando…

Extremely High-Quality Periodic Structures on ITO Film Efficiently Fabricated by Femtosecond Pulse Train Output from a Frequency-Doubled Fabry–Perot Cavity

This study developed a novel frequency-doubled Fabry–Perot cavity method based on a femtosecond laser of 1030 nm, 190 fs, 1 mJ, and 1 kHz. The time interval (60–1000 ps) and attenuation ratio (0.5–0.9) between adjacent sub-pulses of the 515 nm pulse train were able to be easily adjusted, while the e...

Descripción completa

Detalles Bibliográficos
Autores principales: Jiang, Qilin, Zhang, Yuchan, Xu, Yufeng, Zhang, Shian, Feng, Donghai, Jia, Tianqing, Sun, Zhenrong, Qiu, Jianrong
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10179915/
https://www.ncbi.nlm.nih.gov/pubmed/37177054
http://dx.doi.org/10.3390/nano13091510
_version_ 1785041211044659200
author Jiang, Qilin
Zhang, Yuchan
Xu, Yufeng
Zhang, Shian
Feng, Donghai
Jia, Tianqing
Sun, Zhenrong
Qiu, Jianrong
author_facet Jiang, Qilin
Zhang, Yuchan
Xu, Yufeng
Zhang, Shian
Feng, Donghai
Jia, Tianqing
Sun, Zhenrong
Qiu, Jianrong
author_sort Jiang, Qilin
collection PubMed
description This study developed a novel frequency-doubled Fabry–Perot cavity method based on a femtosecond laser of 1030 nm, 190 fs, 1 mJ, and 1 kHz. The time interval (60–1000 ps) and attenuation ratio (0.5–0.9) between adjacent sub-pulses of the 515 nm pulse train were able to be easily adjusted, while the efficiency was up to 50% and remained unchanged. Extremely high-quality low-spatial-frequency LIPSS (LSFL) was efficiently fabricated on an indium tin oxide (ITO) film using a pulse train with a time interval of 150 ps and attenuation ratio of 0.9 focused with a cylindrical lens. Compared with the LSFL induced by the primary Gaussian pulse, the uniformity of the LSFL period was enhanced from 481 ± 41 nm to 435 ± 8 nm, the divergence of structural orientation angle was reduced from 15.6° to 3.7°, and the depth was enhanced from 74.21 ± 14.35 nm to 150.6 ± 8.63 nm. The average line edge roughness and line height roughness were only 7.34 nm and 2.06 nm, respectively. The depths and roughness values were close to or exceeded those of resist lines made by the interference lithography. Compared with the common Fabry–Perot cavity, the laser energy efficiency of the pulse trains and manufacturing efficiency were enhanced by factors of 19 and 25. A very colorful “lotus” pattern with a size of 30×28 mm(2) was demonstrated, which was covered with high-quality LSFLs fabricated by a pulse train with optimized laser parameters. Pulse trains can efficiently enhance and prolong the excitation of surface plasmon polaritons, inhibit deposition particles, depress ablation residual heat and thermal shock waves, and eliminate high-spatial-frequency LIPSS formed on LSFL, therefore, producing extremely high-quality LSFL on ITO films.
format Online
Article
Text
id pubmed-10179915
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-101799152023-05-13 Extremely High-Quality Periodic Structures on ITO Film Efficiently Fabricated by Femtosecond Pulse Train Output from a Frequency-Doubled Fabry–Perot Cavity Jiang, Qilin Zhang, Yuchan Xu, Yufeng Zhang, Shian Feng, Donghai Jia, Tianqing Sun, Zhenrong Qiu, Jianrong Nanomaterials (Basel) Article This study developed a novel frequency-doubled Fabry–Perot cavity method based on a femtosecond laser of 1030 nm, 190 fs, 1 mJ, and 1 kHz. The time interval (60–1000 ps) and attenuation ratio (0.5–0.9) between adjacent sub-pulses of the 515 nm pulse train were able to be easily adjusted, while the efficiency was up to 50% and remained unchanged. Extremely high-quality low-spatial-frequency LIPSS (LSFL) was efficiently fabricated on an indium tin oxide (ITO) film using a pulse train with a time interval of 150 ps and attenuation ratio of 0.9 focused with a cylindrical lens. Compared with the LSFL induced by the primary Gaussian pulse, the uniformity of the LSFL period was enhanced from 481 ± 41 nm to 435 ± 8 nm, the divergence of structural orientation angle was reduced from 15.6° to 3.7°, and the depth was enhanced from 74.21 ± 14.35 nm to 150.6 ± 8.63 nm. The average line edge roughness and line height roughness were only 7.34 nm and 2.06 nm, respectively. The depths and roughness values were close to or exceeded those of resist lines made by the interference lithography. Compared with the common Fabry–Perot cavity, the laser energy efficiency of the pulse trains and manufacturing efficiency were enhanced by factors of 19 and 25. A very colorful “lotus” pattern with a size of 30×28 mm(2) was demonstrated, which was covered with high-quality LSFLs fabricated by a pulse train with optimized laser parameters. Pulse trains can efficiently enhance and prolong the excitation of surface plasmon polaritons, inhibit deposition particles, depress ablation residual heat and thermal shock waves, and eliminate high-spatial-frequency LIPSS formed on LSFL, therefore, producing extremely high-quality LSFL on ITO films. MDPI 2023-04-28 /pmc/articles/PMC10179915/ /pubmed/37177054 http://dx.doi.org/10.3390/nano13091510 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Jiang, Qilin
Zhang, Yuchan
Xu, Yufeng
Zhang, Shian
Feng, Donghai
Jia, Tianqing
Sun, Zhenrong
Qiu, Jianrong
Extremely High-Quality Periodic Structures on ITO Film Efficiently Fabricated by Femtosecond Pulse Train Output from a Frequency-Doubled Fabry–Perot Cavity
title Extremely High-Quality Periodic Structures on ITO Film Efficiently Fabricated by Femtosecond Pulse Train Output from a Frequency-Doubled Fabry–Perot Cavity
title_full Extremely High-Quality Periodic Structures on ITO Film Efficiently Fabricated by Femtosecond Pulse Train Output from a Frequency-Doubled Fabry–Perot Cavity
title_fullStr Extremely High-Quality Periodic Structures on ITO Film Efficiently Fabricated by Femtosecond Pulse Train Output from a Frequency-Doubled Fabry–Perot Cavity
title_full_unstemmed Extremely High-Quality Periodic Structures on ITO Film Efficiently Fabricated by Femtosecond Pulse Train Output from a Frequency-Doubled Fabry–Perot Cavity
title_short Extremely High-Quality Periodic Structures on ITO Film Efficiently Fabricated by Femtosecond Pulse Train Output from a Frequency-Doubled Fabry–Perot Cavity
title_sort extremely high-quality periodic structures on ito film efficiently fabricated by femtosecond pulse train output from a frequency-doubled fabry–perot cavity
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10179915/
https://www.ncbi.nlm.nih.gov/pubmed/37177054
http://dx.doi.org/10.3390/nano13091510
work_keys_str_mv AT jiangqilin extremelyhighqualityperiodicstructuresonitofilmefficientlyfabricatedbyfemtosecondpulsetrainoutputfromafrequencydoubledfabryperotcavity
AT zhangyuchan extremelyhighqualityperiodicstructuresonitofilmefficientlyfabricatedbyfemtosecondpulsetrainoutputfromafrequencydoubledfabryperotcavity
AT xuyufeng extremelyhighqualityperiodicstructuresonitofilmefficientlyfabricatedbyfemtosecondpulsetrainoutputfromafrequencydoubledfabryperotcavity
AT zhangshian extremelyhighqualityperiodicstructuresonitofilmefficientlyfabricatedbyfemtosecondpulsetrainoutputfromafrequencydoubledfabryperotcavity
AT fengdonghai extremelyhighqualityperiodicstructuresonitofilmefficientlyfabricatedbyfemtosecondpulsetrainoutputfromafrequencydoubledfabryperotcavity
AT jiatianqing extremelyhighqualityperiodicstructuresonitofilmefficientlyfabricatedbyfemtosecondpulsetrainoutputfromafrequencydoubledfabryperotcavity
AT sunzhenrong extremelyhighqualityperiodicstructuresonitofilmefficientlyfabricatedbyfemtosecondpulsetrainoutputfromafrequencydoubledfabryperotcavity
AT qiujianrong extremelyhighqualityperiodicstructuresonitofilmefficientlyfabricatedbyfemtosecondpulsetrainoutputfromafrequencydoubledfabryperotcavity