Cargando…

Comparative study of quality of leukoreduced packed red blood cell units as assessed by nageotte hemocytometry and flow cytometry

PURPOSE: Assessment of residual white blood cell (rWBC) count is vital to ascertain the quality of leukodepleted (LD) blood components. Automated cell analyzers lack the sensitivity for the assessment of very few leukocytes as found in LD blood components. Flow Cytometry (FC) based methods and Nageo...

Descripción completa

Detalles Bibliográficos
Autores principales: Sheikh, Mohd Anas, Biswas, Amit Kumar, Baranwal, Ajay Kumar, Kushwaha, Neerja, Karade, Santosh, Philip, Joseph
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Wolters Kluwer - Medknow 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10180788/
https://www.ncbi.nlm.nih.gov/pubmed/37188022
http://dx.doi.org/10.4103/ajts.AJTS_101_21
_version_ 1785041418603986944
author Sheikh, Mohd Anas
Biswas, Amit Kumar
Baranwal, Ajay Kumar
Kushwaha, Neerja
Karade, Santosh
Philip, Joseph
author_facet Sheikh, Mohd Anas
Biswas, Amit Kumar
Baranwal, Ajay Kumar
Kushwaha, Neerja
Karade, Santosh
Philip, Joseph
author_sort Sheikh, Mohd Anas
collection PubMed
description PURPOSE: Assessment of residual white blood cell (rWBC) count is vital to ascertain the quality of leukodepleted (LD) blood components. Automated cell analyzers lack the sensitivity for the assessment of very few leukocytes as found in LD blood components. Flow Cytometry (FC) based methods and Nageotte hemocytometer are the most commonly used techniques for this purpose. The objective of this study was to compare the use of Nageotte hemocytometer and FC for quality control of LD red blood cell units. MATERIALS AND METHODS: A prospective, observational study was conducted in the Department of Immunohematology and Blood Transfusion of a tertiary care center from September 2018 to September 2020. About 303 LD-packed red blood cell units were tested by FC and Nageotte hemocytometer for rWBCs. RESULTS: The number of rWBC (mean) detected by flow cytometer and Nageotte's hemocytometer was 1.06 ± 0.43 white blood cell (WBC)/μL and 0.67 ± 0.39 WBC/μL, respectively. Coefficient of variation was 58.37% by Nageotte hemocytometer method and 40.46% by FC. Linear regression analysis did not show any correlation (R(2)= 0.098, P = 0.001) whereas Pearson's correlation coefficient showed a weak relation (r = 0.31) between the two methods. CONCLUSION: Flow cytometric technique provides a more precise and accurate objective tool compared to Nageotte hemocytometer which is labor intensive, time consuming, and prone to errors arising out of subjectivity along with reported underestimation bias. In the absence of adequate infrastructure, resources, and trained workforce, Nageotte hemocytometer method is a reliable alternative. Nageotte's chamber could be best used in the resource-constrained setup as it offers a relatively inexpensive, simple, and viable means to enumerate rWBCs.
format Online
Article
Text
id pubmed-10180788
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Wolters Kluwer - Medknow
record_format MEDLINE/PubMed
spelling pubmed-101807882023-05-13 Comparative study of quality of leukoreduced packed red blood cell units as assessed by nageotte hemocytometry and flow cytometry Sheikh, Mohd Anas Biswas, Amit Kumar Baranwal, Ajay Kumar Kushwaha, Neerja Karade, Santosh Philip, Joseph Asian J Transfus Sci Original Article PURPOSE: Assessment of residual white blood cell (rWBC) count is vital to ascertain the quality of leukodepleted (LD) blood components. Automated cell analyzers lack the sensitivity for the assessment of very few leukocytes as found in LD blood components. Flow Cytometry (FC) based methods and Nageotte hemocytometer are the most commonly used techniques for this purpose. The objective of this study was to compare the use of Nageotte hemocytometer and FC for quality control of LD red blood cell units. MATERIALS AND METHODS: A prospective, observational study was conducted in the Department of Immunohematology and Blood Transfusion of a tertiary care center from September 2018 to September 2020. About 303 LD-packed red blood cell units were tested by FC and Nageotte hemocytometer for rWBCs. RESULTS: The number of rWBC (mean) detected by flow cytometer and Nageotte's hemocytometer was 1.06 ± 0.43 white blood cell (WBC)/μL and 0.67 ± 0.39 WBC/μL, respectively. Coefficient of variation was 58.37% by Nageotte hemocytometer method and 40.46% by FC. Linear regression analysis did not show any correlation (R(2)= 0.098, P = 0.001) whereas Pearson's correlation coefficient showed a weak relation (r = 0.31) between the two methods. CONCLUSION: Flow cytometric technique provides a more precise and accurate objective tool compared to Nageotte hemocytometer which is labor intensive, time consuming, and prone to errors arising out of subjectivity along with reported underestimation bias. In the absence of adequate infrastructure, resources, and trained workforce, Nageotte hemocytometer method is a reliable alternative. Nageotte's chamber could be best used in the resource-constrained setup as it offers a relatively inexpensive, simple, and viable means to enumerate rWBCs. Wolters Kluwer - Medknow 2023 2022-09-28 /pmc/articles/PMC10180788/ /pubmed/37188022 http://dx.doi.org/10.4103/ajts.AJTS_101_21 Text en Copyright: © 2022 Asian Journal of Transfusion Science https://creativecommons.org/licenses/by-nc-sa/4.0/This is an open access journal, and articles are distributed under the terms of the Creative Commons Attribution-NonCommercial-ShareAlike 4.0 License, which allows others to remix, tweak, and build upon the work non-commercially, as long as appropriate credit is given and the new creations are licensed under the identical terms.
spellingShingle Original Article
Sheikh, Mohd Anas
Biswas, Amit Kumar
Baranwal, Ajay Kumar
Kushwaha, Neerja
Karade, Santosh
Philip, Joseph
Comparative study of quality of leukoreduced packed red blood cell units as assessed by nageotte hemocytometry and flow cytometry
title Comparative study of quality of leukoreduced packed red blood cell units as assessed by nageotte hemocytometry and flow cytometry
title_full Comparative study of quality of leukoreduced packed red blood cell units as assessed by nageotte hemocytometry and flow cytometry
title_fullStr Comparative study of quality of leukoreduced packed red blood cell units as assessed by nageotte hemocytometry and flow cytometry
title_full_unstemmed Comparative study of quality of leukoreduced packed red blood cell units as assessed by nageotte hemocytometry and flow cytometry
title_short Comparative study of quality of leukoreduced packed red blood cell units as assessed by nageotte hemocytometry and flow cytometry
title_sort comparative study of quality of leukoreduced packed red blood cell units as assessed by nageotte hemocytometry and flow cytometry
topic Original Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10180788/
https://www.ncbi.nlm.nih.gov/pubmed/37188022
http://dx.doi.org/10.4103/ajts.AJTS_101_21
work_keys_str_mv AT sheikhmohdanas comparativestudyofqualityofleukoreducedpackedredbloodcellunitsasassessedbynageottehemocytometryandflowcytometry
AT biswasamitkumar comparativestudyofqualityofleukoreducedpackedredbloodcellunitsasassessedbynageottehemocytometryandflowcytometry
AT baranwalajaykumar comparativestudyofqualityofleukoreducedpackedredbloodcellunitsasassessedbynageottehemocytometryandflowcytometry
AT kushwahaneerja comparativestudyofqualityofleukoreducedpackedredbloodcellunitsasassessedbynageottehemocytometryandflowcytometry
AT karadesantosh comparativestudyofqualityofleukoreducedpackedredbloodcellunitsasassessedbynageottehemocytometryandflowcytometry
AT philipjoseph comparativestudyofqualityofleukoreducedpackedredbloodcellunitsasassessedbynageottehemocytometryandflowcytometry