Cargando…

Performance of the FreeStyle Libre Flash Glucose Monitoring System during an Oral Glucose Tolerance Test and Exercise in Healthy Adolescents

This study’s aim was to assess FreeStyle Libre Flash glucose monitoring (FGM) performance during an oral glucose tolerance test (OGTT) and treadmill exercise in healthy adolescents. This should advance the feasibility and utility of user-friendly technologies for metabolic assessments in adolescents...

Descripción completa

Detalles Bibliográficos
Autores principales: Afeef, Sahar, Tolfrey, Keith, Zakrzewski-Fruer, Julia K., Barrett, Laura A.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10180860/
https://www.ncbi.nlm.nih.gov/pubmed/37177452
http://dx.doi.org/10.3390/s23094249
_version_ 1785041435915976704
author Afeef, Sahar
Tolfrey, Keith
Zakrzewski-Fruer, Julia K.
Barrett, Laura A.
author_facet Afeef, Sahar
Tolfrey, Keith
Zakrzewski-Fruer, Julia K.
Barrett, Laura A.
author_sort Afeef, Sahar
collection PubMed
description This study’s aim was to assess FreeStyle Libre Flash glucose monitoring (FGM) performance during an oral glucose tolerance test (OGTT) and treadmill exercise in healthy adolescents. This should advance the feasibility and utility of user-friendly technologies for metabolic assessments in adolescents. Seventeen healthy adolescents (nine girls aged 12.8 ± 0.9 years) performed an OGTT and submaximal and maximal treadmill exercise tests in a laboratory setting. The scanned interstitial fluid glucose concentration ([ISFG]) obtained by FGM was compared against finger-prick capillary plasma glucose concentration ([CPG]) at 0 (pre-OGTT), −15, −30, −60, −120 min post-OGTT, pre-, mid-, post- submaximal exercise, and pre- and post- maximal exercise. Overall mean absolute relative difference (MARD) was 13.1 ± 8.5%, and 68% (n = 113) of the paired glucose data met the ISO 15197:2013 criteria. For clinical accuracy, 84% and 16% of FGM readings were within zones A and B in the Consensus Error Grid (CEG), respectively, which met the ISO 15197:2013 criteria of having at least 99% of results within these zones. Scanned [ISFG] were statistically lower than [CPG] at 15 (−1.16 mmol∙L(−1), p < 0.001) and 30 min (−0.74 mmol∙L(−1), p = 0.041) post-OGTT. Yet, post-OGTT glycaemic responses assessed by total and incremental areas under the curve (AUCs) were not significantly different, with trivial to small effect sizes (p ≥ 0.084, d = 0.14–0.45). Further, [ISFGs] were not different from [CPGs] during submaximal and maximal exercise tests (interaction p ≥ 0.614). FGM can be a feasible alternative to reflect postprandial glycaemia (AUCs) in healthy adolescents who may not endure repeated finger pricks.
format Online
Article
Text
id pubmed-10180860
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-101808602023-05-13 Performance of the FreeStyle Libre Flash Glucose Monitoring System during an Oral Glucose Tolerance Test and Exercise in Healthy Adolescents Afeef, Sahar Tolfrey, Keith Zakrzewski-Fruer, Julia K. Barrett, Laura A. Sensors (Basel) Article This study’s aim was to assess FreeStyle Libre Flash glucose monitoring (FGM) performance during an oral glucose tolerance test (OGTT) and treadmill exercise in healthy adolescents. This should advance the feasibility and utility of user-friendly technologies for metabolic assessments in adolescents. Seventeen healthy adolescents (nine girls aged 12.8 ± 0.9 years) performed an OGTT and submaximal and maximal treadmill exercise tests in a laboratory setting. The scanned interstitial fluid glucose concentration ([ISFG]) obtained by FGM was compared against finger-prick capillary plasma glucose concentration ([CPG]) at 0 (pre-OGTT), −15, −30, −60, −120 min post-OGTT, pre-, mid-, post- submaximal exercise, and pre- and post- maximal exercise. Overall mean absolute relative difference (MARD) was 13.1 ± 8.5%, and 68% (n = 113) of the paired glucose data met the ISO 15197:2013 criteria. For clinical accuracy, 84% and 16% of FGM readings were within zones A and B in the Consensus Error Grid (CEG), respectively, which met the ISO 15197:2013 criteria of having at least 99% of results within these zones. Scanned [ISFG] were statistically lower than [CPG] at 15 (−1.16 mmol∙L(−1), p < 0.001) and 30 min (−0.74 mmol∙L(−1), p = 0.041) post-OGTT. Yet, post-OGTT glycaemic responses assessed by total and incremental areas under the curve (AUCs) were not significantly different, with trivial to small effect sizes (p ≥ 0.084, d = 0.14–0.45). Further, [ISFGs] were not different from [CPGs] during submaximal and maximal exercise tests (interaction p ≥ 0.614). FGM can be a feasible alternative to reflect postprandial glycaemia (AUCs) in healthy adolescents who may not endure repeated finger pricks. MDPI 2023-04-25 /pmc/articles/PMC10180860/ /pubmed/37177452 http://dx.doi.org/10.3390/s23094249 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Afeef, Sahar
Tolfrey, Keith
Zakrzewski-Fruer, Julia K.
Barrett, Laura A.
Performance of the FreeStyle Libre Flash Glucose Monitoring System during an Oral Glucose Tolerance Test and Exercise in Healthy Adolescents
title Performance of the FreeStyle Libre Flash Glucose Monitoring System during an Oral Glucose Tolerance Test and Exercise in Healthy Adolescents
title_full Performance of the FreeStyle Libre Flash Glucose Monitoring System during an Oral Glucose Tolerance Test and Exercise in Healthy Adolescents
title_fullStr Performance of the FreeStyle Libre Flash Glucose Monitoring System during an Oral Glucose Tolerance Test and Exercise in Healthy Adolescents
title_full_unstemmed Performance of the FreeStyle Libre Flash Glucose Monitoring System during an Oral Glucose Tolerance Test and Exercise in Healthy Adolescents
title_short Performance of the FreeStyle Libre Flash Glucose Monitoring System during an Oral Glucose Tolerance Test and Exercise in Healthy Adolescents
title_sort performance of the freestyle libre flash glucose monitoring system during an oral glucose tolerance test and exercise in healthy adolescents
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10180860/
https://www.ncbi.nlm.nih.gov/pubmed/37177452
http://dx.doi.org/10.3390/s23094249
work_keys_str_mv AT afeefsahar performanceofthefreestylelibreflashglucosemonitoringsystemduringanoralglucosetolerancetestandexerciseinhealthyadolescents
AT tolfreykeith performanceofthefreestylelibreflashglucosemonitoringsystemduringanoralglucosetolerancetestandexerciseinhealthyadolescents
AT zakrzewskifruerjuliak performanceofthefreestylelibreflashglucosemonitoringsystemduringanoralglucosetolerancetestandexerciseinhealthyadolescents
AT barrettlauraa performanceofthefreestylelibreflashglucosemonitoringsystemduringanoralglucosetolerancetestandexerciseinhealthyadolescents