Evaluation of Spatial Gas Temperature and Water Vapor Inhomogeneities in TDLAS in Circular Multipass Absorption Cells Used for the Analysis of Dynamic Tube Flows

The use of optical circular multipass absorption cells (CMPAC) in an open-path configuration enables the sampling free analysis of cylindrical gas flows with high temporal resolution and only minimal disturbances to the sample gas in the pipe. Combined with their robust unibody design, CMPACs are a...

Descripción completa

Detalles Bibliográficos
Autores principales: Witt, Felix, Bohlius, Henning, Ebert, Volker
Formato: Online Artículo Texto
Lenguaje:English
Publicado: MDPI 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10181621/
https://www.ncbi.nlm.nih.gov/pubmed/37177547
http://dx.doi.org/10.3390/s23094345
_version_ 1785041618157436928
author Witt, Felix
Bohlius, Henning
Ebert, Volker
author_facet Witt, Felix
Bohlius, Henning
Ebert, Volker
author_sort Witt, Felix
collection PubMed
description The use of optical circular multipass absorption cells (CMPAC) in an open-path configuration enables the sampling free analysis of cylindrical gas flows with high temporal resolution and only minimal disturbances to the sample gas in the pipe. Combined with their robust unibody design, CMPACs are a good option for many applications in atmospheric research and industrial process monitoring. When deployed in an open-path configuration, the effects of inhomogeneities in the gas temperature and composition have to be evaluated to ensure that the resulting measurement error is acceptable for a given application. Such an evaluation needs to consider the deviations caused by spectroscopic effects, e.g., nonlinear effects of temperature variations on the intensity of the spectral line, as well as the interaction of the temperature and concentration field with the characteristic laser beam pattern of the CMPAC. In this work we demonstrate this novel combined evaluation approach for the CMPAC used as part of the tunable diode laser absorption spectroscopy (TDLAS) reference hygrometer in PTB’s dynH(2)O setup for the characterization of the dynamic response behavior of hygrometers. For this, we measured spatially resolved, 2D temperature and H(2)O concentration distributions, and combined them with spatially resolved simulated spectra to evaluate the inhomogeneity effects on the line area of the used H(2)O spectral line at 7299.43 cm(−1). Our results indicate that for dynH(2)O, the deviations caused by the interaction between large concentration heterogeneities and the characteristic sampling of the beam pattern of the CMPAC are three orders of magnitude larger than deviations caused by small temperature heterogeneity induced spectroscopic effects. We also deduce that the assumption that the “path-integrated” H(2)O concentration derived with the open-path CMPAC setup represents an accurate H(2)O area average in the flow section covered by the CMPAC in fact shows significant differences of up to 16% and hence does not hold true when large H(2)O concentration gradients are present.
format Online
Article
Text
id pubmed-10181621
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher MDPI
record_format MEDLINE/PubMed
spelling pubmed-101816212023-05-13 Evaluation of Spatial Gas Temperature and Water Vapor Inhomogeneities in TDLAS in Circular Multipass Absorption Cells Used for the Analysis of Dynamic Tube Flows Witt, Felix Bohlius, Henning Ebert, Volker Sensors (Basel) Article The use of optical circular multipass absorption cells (CMPAC) in an open-path configuration enables the sampling free analysis of cylindrical gas flows with high temporal resolution and only minimal disturbances to the sample gas in the pipe. Combined with their robust unibody design, CMPACs are a good option for many applications in atmospheric research and industrial process monitoring. When deployed in an open-path configuration, the effects of inhomogeneities in the gas temperature and composition have to be evaluated to ensure that the resulting measurement error is acceptable for a given application. Such an evaluation needs to consider the deviations caused by spectroscopic effects, e.g., nonlinear effects of temperature variations on the intensity of the spectral line, as well as the interaction of the temperature and concentration field with the characteristic laser beam pattern of the CMPAC. In this work we demonstrate this novel combined evaluation approach for the CMPAC used as part of the tunable diode laser absorption spectroscopy (TDLAS) reference hygrometer in PTB’s dynH(2)O setup for the characterization of the dynamic response behavior of hygrometers. For this, we measured spatially resolved, 2D temperature and H(2)O concentration distributions, and combined them with spatially resolved simulated spectra to evaluate the inhomogeneity effects on the line area of the used H(2)O spectral line at 7299.43 cm(−1). Our results indicate that for dynH(2)O, the deviations caused by the interaction between large concentration heterogeneities and the characteristic sampling of the beam pattern of the CMPAC are three orders of magnitude larger than deviations caused by small temperature heterogeneity induced spectroscopic effects. We also deduce that the assumption that the “path-integrated” H(2)O concentration derived with the open-path CMPAC setup represents an accurate H(2)O area average in the flow section covered by the CMPAC in fact shows significant differences of up to 16% and hence does not hold true when large H(2)O concentration gradients are present. MDPI 2023-04-27 /pmc/articles/PMC10181621/ /pubmed/37177547 http://dx.doi.org/10.3390/s23094345 Text en © 2023 by the authors. https://creativecommons.org/licenses/by/4.0/Licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (https://creativecommons.org/licenses/by/4.0/).
spellingShingle Article
Witt, Felix
Bohlius, Henning
Ebert, Volker
Evaluation of Spatial Gas Temperature and Water Vapor Inhomogeneities in TDLAS in Circular Multipass Absorption Cells Used for the Analysis of Dynamic Tube Flows
title Evaluation of Spatial Gas Temperature and Water Vapor Inhomogeneities in TDLAS in Circular Multipass Absorption Cells Used for the Analysis of Dynamic Tube Flows
title_full Evaluation of Spatial Gas Temperature and Water Vapor Inhomogeneities in TDLAS in Circular Multipass Absorption Cells Used for the Analysis of Dynamic Tube Flows
title_fullStr Evaluation of Spatial Gas Temperature and Water Vapor Inhomogeneities in TDLAS in Circular Multipass Absorption Cells Used for the Analysis of Dynamic Tube Flows
title_full_unstemmed Evaluation of Spatial Gas Temperature and Water Vapor Inhomogeneities in TDLAS in Circular Multipass Absorption Cells Used for the Analysis of Dynamic Tube Flows
title_short Evaluation of Spatial Gas Temperature and Water Vapor Inhomogeneities in TDLAS in Circular Multipass Absorption Cells Used for the Analysis of Dynamic Tube Flows
title_sort evaluation of spatial gas temperature and water vapor inhomogeneities in tdlas in circular multipass absorption cells used for the analysis of dynamic tube flows
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10181621/
https://www.ncbi.nlm.nih.gov/pubmed/37177547
http://dx.doi.org/10.3390/s23094345
work_keys_str_mv AT wittfelix evaluationofspatialgastemperatureandwatervaporinhomogeneitiesintdlasincircularmultipassabsorptioncellsusedfortheanalysisofdynamictubeflows
AT bohliushenning evaluationofspatialgastemperatureandwatervaporinhomogeneitiesintdlasincircularmultipassabsorptioncellsusedfortheanalysisofdynamictubeflows
AT ebertvolker evaluationofspatialgastemperatureandwatervaporinhomogeneitiesintdlasincircularmultipassabsorptioncellsusedfortheanalysisofdynamictubeflows