Cargando…
Transanal formation of anastomosis using C-REX device is feasible and effective in high anterior resection
PURPOSE: C-REX is a novel instrument for creating stapleless colorectal anastomosis by compression. The aim of this study was to evaluate the feasibility and effectiveness of C-REX in open and laparoscopic high anterior resections. METHODS: A prospective clinical safety study on 21 patients reconstr...
Autores principales: | , , , , |
---|---|
Formato: | Online Artículo Texto |
Lenguaje: | English |
Publicado: |
Springer Berlin Heidelberg
2023
|
Materias: | |
Acceso en línea: | https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10182144/ https://www.ncbi.nlm.nih.gov/pubmed/37173554 http://dx.doi.org/10.1007/s00384-023-04420-x |
Sumario: | PURPOSE: C-REX is a novel instrument for creating stapleless colorectal anastomosis by compression. The aim of this study was to evaluate the feasibility and effectiveness of C-REX in open and laparoscopic high anterior resections. METHODS: A prospective clinical safety study on 21 patients reconstructed with C-REX colorectal anastomosis following high anterior resection of the sigmoid colon using two different devices for intraabdominal (n = 6) or transanal (n = 15) placement of the anastomotic rings. Any signs of complications were prospectively monitored by a predefined protocol. Anastomotic contact pressure (ACP) was measured via a catheter-based system, and time for evacuation of the anastomotic rings by the natural route was noted. Blood samples were collected daily, and flexible endoscopy was performed postoperatively to examine macroscopic appearance of the anastomoses. RESULTS: One of six patients operated with the intraabdominal anastomosis technique with an ACP of 50 mBar had to be reoperated because of anastomotic leakage. None of the 15 patients operated with the transanal technique (5 open and 10 laparoscopic procedures) had anastomotic complications, and their ACP ranged between 145 and 300 mBar. C-REX rings were uneventfully expelled by the natural route in all patients after a median of 10 days. Flexible endoscopy showed well-healed anastomoses without stenosis in 17 patients and a moderate subclinical stricture in one patient. CONCLUSION: These results indicate that the novel transanal C-REX device is a feasible and effective method for colorectal anastomosis following high anterior resections, irrespective of open or laparoscopic approach. Moreover, C-REX allows measurement of intraoperative ACP and thereby a quantitative evaluation of the anastomotic integrity. SUPPLEMENTARY INFORMATION: The online version contains supplementary material available at 10.1007/s00384-023-04420-x. |
---|