Cargando…

Content aware image restoration improves spatiotemporal resolution in luminescence imaging

Luminescent reporters are due to their intrinsically high signal-to-noise ratio a powerful labelling tool for microscopy and macroscopic in vivo imaging in biomedical research. However, luminescence signal detection requires longer exposure times than fluorescence imaging and is consequently less su...

Descripción completa

Detalles Bibliográficos
Autores principales: Boothe, Tobias, Ivanković, Mario, Grohme, Markus A., Markus, M. Andrea, Dullin, Christian, Xu, Xingbo, Rink, Jochen C.
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Nature Publishing Group UK 2023
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10183019/
https://www.ncbi.nlm.nih.gov/pubmed/37179375
http://dx.doi.org/10.1038/s42003-023-04886-z
_version_ 1785041869314457600
author Boothe, Tobias
Ivanković, Mario
Grohme, Markus A.
Markus, M. Andrea
Dullin, Christian
Xu, Xingbo
Rink, Jochen C.
author_facet Boothe, Tobias
Ivanković, Mario
Grohme, Markus A.
Markus, M. Andrea
Dullin, Christian
Xu, Xingbo
Rink, Jochen C.
author_sort Boothe, Tobias
collection PubMed
description Luminescent reporters are due to their intrinsically high signal-to-noise ratio a powerful labelling tool for microscopy and macroscopic in vivo imaging in biomedical research. However, luminescence signal detection requires longer exposure times than fluorescence imaging and is consequently less suited for applications requiring high temporal resolution or throughput. Here we demonstrate that content aware image restoration can drastically reduce the exposure time requirements in luminescence imaging, thus overcoming one of the major limitations of the technique.
format Online
Article
Text
id pubmed-10183019
institution National Center for Biotechnology Information
language English
publishDate 2023
publisher Nature Publishing Group UK
record_format MEDLINE/PubMed
spelling pubmed-101830192023-05-15 Content aware image restoration improves spatiotemporal resolution in luminescence imaging Boothe, Tobias Ivanković, Mario Grohme, Markus A. Markus, M. Andrea Dullin, Christian Xu, Xingbo Rink, Jochen C. Commun Biol Article Luminescent reporters are due to their intrinsically high signal-to-noise ratio a powerful labelling tool for microscopy and macroscopic in vivo imaging in biomedical research. However, luminescence signal detection requires longer exposure times than fluorescence imaging and is consequently less suited for applications requiring high temporal resolution or throughput. Here we demonstrate that content aware image restoration can drastically reduce the exposure time requirements in luminescence imaging, thus overcoming one of the major limitations of the technique. Nature Publishing Group UK 2023-05-13 /pmc/articles/PMC10183019/ /pubmed/37179375 http://dx.doi.org/10.1038/s42003-023-04886-z Text en © The Author(s) 2023 https://creativecommons.org/licenses/by/4.0/Open Access This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. The images or other third party material in this article are included in the article’s Creative Commons license, unless indicated otherwise in a credit line to the material. If material is not included in the article’s Creative Commons license and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this license, visit http://creativecommons.org/licenses/by/4.0/ (https://creativecommons.org/licenses/by/4.0/) .
spellingShingle Article
Boothe, Tobias
Ivanković, Mario
Grohme, Markus A.
Markus, M. Andrea
Dullin, Christian
Xu, Xingbo
Rink, Jochen C.
Content aware image restoration improves spatiotemporal resolution in luminescence imaging
title Content aware image restoration improves spatiotemporal resolution in luminescence imaging
title_full Content aware image restoration improves spatiotemporal resolution in luminescence imaging
title_fullStr Content aware image restoration improves spatiotemporal resolution in luminescence imaging
title_full_unstemmed Content aware image restoration improves spatiotemporal resolution in luminescence imaging
title_short Content aware image restoration improves spatiotemporal resolution in luminescence imaging
title_sort content aware image restoration improves spatiotemporal resolution in luminescence imaging
topic Article
url https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10183019/
https://www.ncbi.nlm.nih.gov/pubmed/37179375
http://dx.doi.org/10.1038/s42003-023-04886-z
work_keys_str_mv AT boothetobias contentawareimagerestorationimprovesspatiotemporalresolutioninluminescenceimaging
AT ivankovicmario contentawareimagerestorationimprovesspatiotemporalresolutioninluminescenceimaging
AT grohmemarkusa contentawareimagerestorationimprovesspatiotemporalresolutioninluminescenceimaging
AT markusmandrea contentawareimagerestorationimprovesspatiotemporalresolutioninluminescenceimaging
AT dullinchristian contentawareimagerestorationimprovesspatiotemporalresolutioninluminescenceimaging
AT xuxingbo contentawareimagerestorationimprovesspatiotemporalresolutioninluminescenceimaging
AT rinkjochenc contentawareimagerestorationimprovesspatiotemporalresolutioninluminescenceimaging