Cargando…

SpO(2), heart rate, and arterial blood pressure during successful or failed application of non-invasive ventilation after delivery – a single-centre study

BACKGROUND: SpO(2), heart rate, and systolic, diastolic, and mean arterial blood pressure are among the commonly applied and most frequently chosen indicators of well-being of newborns in intensive care units. Objective: to determine the relationship between the aforementioned parameters and the sta...

Descripción completa

Detalles Bibliográficos
Autores principales: Czeszyńska, Maria Beata, Sontowska, Agnieszka
Formato: Online Artículo Texto
Lenguaje:English
Publicado: Termedia Publishing House 2020
Materias:
Acceso en línea:https://www.ncbi.nlm.nih.gov/pmc/articles/PMC10183777/
https://www.ncbi.nlm.nih.gov/pubmed/33165881
http://dx.doi.org/10.5114/ait.2020.100574
Descripción
Sumario:BACKGROUND: SpO(2), heart rate, and systolic, diastolic, and mean arterial blood pressure are among the commonly applied and most frequently chosen indicators of well-being of newborns in intensive care units. Objective: to determine the relationship between the aforementioned parameters and the status of newborns depending on the outcome of the Infant Flow (I-F) therapy, and the development of complications in the form of pneumothorax. METHODS: A retrospective single-centre study covering the years 2009–2014. A total of 182 neonates, with mean gestational age 34.1 weeks and mean body weight 2226 g, were analysed. The minimum and maximum values of the evaluated parameters were analysed statistically according to the therapy outcome noted as success or failure. RESULTS: A successful outcome of I-F therapy (71.4%) was characterised by higher SpO(2) (93.3 ±7.28 vs. 85.9 ±14.77 at P < 0.001; 99.95 ±0.31 vs. 98.6 ±3.30 at P < 0.0001), lower heart rate (122.5 ±12.37 vs. 135.9 ±14.97 at P < 0.0001), and higher max systolic blood pressure (79.05 ±12.49 vs. 69.78 ±13.73 mm Hg at P < 0.0001), max diastolic blood pressure (57.03 ±9.31 vs. 50.41 ±13.82 mm Hg; P < 0.0003), and max as well as min mean arterial blood pressure (46.8 ±10.13 vs. 41.39 ±15.46 mm Hg; P < 0.001) (27.88 ±5.71 vs. 26.14 ±7.35 mm Hg; P < 0.02). CONCLUSIONS: In newborns suffering from respiratory failure and treated with I-F, higher SpO(2) values, lower heart rate, and higher arterial blood pressure coincide with success of the I-F therapy.